1 Vogtle PEmails From:

Habib, Donald Sent:

Friday, May 25, 2018 8:52 AM To:

Vogtle PEmails

Subject:

FW: 5/31 Public Meeting: Discussion on LAR 17-037, Perspective of ASME Code Treatment From: Habib, Donald Sent: Thursday, May 24, 2018 3:40 PM To: 'WASPARKM@southernco.com' <WASPARKM@southernco.com>

Cc: 'Haggerty, Neil' <X2NHAGGE@SOUTHERNCO.COM>; 'Amundson, Theodore Edwin' <X2TAMUNS@southernco.com>;

'Hicks, Thomas E.' <X2TEHICK@southernco.com>; Hoellman, Jordan <Jordan.Hoellman2@nrc.gov>; Lupold, Timothy

<Timothy.Lupold@nrc.gov>

Subject:

5/31 Public Meeting: Discussion on LAR 17-037, Perspective of ASME Code Treatment Wes et al. -

At the upcoming public meeting on 5/31, the staff would like to briefly discuss one aspect of LAR 17-037 from the perspective of ASME Code treatment.

Can you confirm that you will be available to discuss this issue (related to SNCs May 11, 2018 submittal, ND-18-0608, ML18131A263)?

Briefly, the staff does not object to making the reference to the code material Tier 2 from Tier 2*, but we want to emphasize that if SNC intends to deviate from ASME Section III code requirements, then it will need to follow the process established in 10 CFR 50.55a for alternatives and relief requests, and not apply the 50.59 like process. The language in the supplemental RAI response related to the example using the words adverse raises a concern. In the instance used, this would be associated with the B31.1 Code, which does not fall under the purview of 10 CFR 50.55a. In this case, while using the 50.59 like process to deviate would be acceptable, this approach would not be the same for ASME Section III, where the 10 CFR 50.55a regulations would apply.

Don Habib Project Manager NRO/DNRL, Licensing Branch 4 O-8D13 301-415-1035

Hearing Identifier:

Vogtle_COL_Docs_Public Email Number:

281 Mail Envelope Properties (BY1PR09MB09357E8A55F0504B5299F01A97690)

Subject:

FW: 5/31 Public Meeting: Discussion on LAR 17-037, Perspective of ASME Code Treatment Sent Date:

5/25/2018 8:51:35 AM Received Date:

5/25/2018 8:51:38 AM From:

Habib, Donald Created By:

Donald.Habib@nrc.gov Recipients:

"Vogtle PEmails" <Vogtle.PEmails@nrc.gov>

Tracking Status: None Post Office:

BY1PR09MB0935.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 1666 5/25/2018 8:51:38 AM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: