ML18145A018
| ML18145A018 | |
| Person / Time | |
|---|---|
| Issue date: | 07/21/1993 |
| From: | Chilk S NRC/SECY |
| To: | Taylor J NRC/EDO |
| Holonich J | |
| References | |
| SRM-SECY-93-087 | |
| Download: ML18145A018 (3) | |
Text
1%o UNITED STATES NUCLEAR REGULATORY COMMISSION
.WASHINGTON, D.C. 20555 July 21, 1993 OFFICE OF THE SECRETARY MEMORANDUM FOR:
James M. Taylor, Executive Director for Operations FROM:
Samuel J.
Chilk, Secret
SUBJECT:
- POLICY, ICAL, AND LICENSING ISSUES PERTANG TO EVOLUTIONARY AND ADVANCED LIGHT-WATER REACTOR (ALWR)
DESIGNS This is to advise you that the Commission (with all Commissioners agreeing) has approved the items for which the staff requested a decision as follows:
- 1. I.E.
Fire Protection:
The Commission approves the staff's position that the passive plants should also be reviewed against the enhanced fire protection criteria approved in the Commission's SRM of June 26, 1990.
The Commission would like to be kept infurmed of the staff's resolution of the issue related to common-mode failures through common ventilation systems.
- 2.
I.F.
Intersystem Loss-of-Coolant Accident:
The Commission approves the staff's position that the passive plants should also be reviewed for compliance with the intersystem LOCA criteria approved in the Commission's SRM of June 26, 1990.
The staff should clarify the intent of the phrase "could not practically be designed to meet such a criterion."
- 3.
I.G.
Hydrogen Control:
The Commission approves the staff's position that the passive plants should be designed, as a minimum, to the same requirements applied to evolutionary designs.
Specifically, passive plants must:
SECY NOTE:
This SRM and the vote sheets of all Commissioners will be made publicly available in 10 working days from the date of this SRM.
(SECY-93-087 was previously released to the public).
The Commission approves the staff's position that traditional probabilistic techniques should be used to evaluate internal floods.
The Commission approves the staff's position that the ALWR vendors should perform bounding analyses of site-specific external events likely to be a challenge to the plant (such as river flooding, storm surge, tsunami, volcanism, high winds, and hucricanes).
The Commission approves the staff's position that when a site is chosen, its characteristics should be compared to those assumed in the bounding analyses to ensure that the site is enveloped.
The Commission approves the staff's position that if the site is enveloped, the COL applicant need not perform further PRA evaluations for these external events.
The COL applicant should perform site-specific PRA evaluations to address any site-specific hazards for which a bounding analysis was not performed or which are not enveloped by the bounding analyses to ensure that no vulnerabilities due to siting exist.
- 18.
II.Q. Defense Against Common-Mode Failures in Digital Instrumentation and Control Systems:
The Commission approves, in part, and disapproves, in part, the staff's recommendation.
The Commission has approved a revised position, as follows:
- 1.
The applicant shall assess the defense-in-depth and diversity of the proposed instrumentation and control system to demonstrate that vulnerabilities to common mode failures have adequately been addressed.
- 2.
In performing the assessment, the vendor or applicant shall analyze each postulated common-mode failure for each event that is evaluated in the accident analysis section of the safety analysis report (SAR) using best estimate methods.
The vendor or applicant shall demonstrate adequate diversity within the design for each of these events.
- 3.
If a postulated common-mode failure could disable a safety function, then a diverse means, with a documented basis that the diverse means is unlikely to be subject to the same common-mode failure, shall be required to perform either the same function or a different function.
The diverse or different function may be performed by a non-safety system if the system 8
While highly integrated digital I&C systems were envisioned when SRM-SECY-93-087 was issued, the resulting BTP 7-19 R4 that implemented the SRM was clearly focused on the RTS/ESFAS and not other safety I&C functions or non-safety control systems. BTP 7-19 R6 is the point that the D3 scope was clearly expanded.
Discussion could be added concerning Point 1 related to the methodology to assess CCF vulnerabilities and a CCF unlikely conclusion.
This statement specifically couples the digital CCF with the occurrence of each of the Chapter 15 events. This approach is appropriate if the scope of the D3 assessment is the RTS or ESFAS. It precludes the use of other coping analyses (e.g.,
station blackout) to assess consequences. The expectations for coping analyses should be harmonized with the scope of applicability to avoid confusion regarding acceptable coping analyses.
This statement may need to be harmonized with the resolution of the expectations for Point 1 for clarity.
This statement should be clarified to allow the case where acceptable coping analyses criteria can be met without credit for a diverse or different function.
is of sufficient quality to perform the necessary function under the associated event conditions.
- 4.
A set of e
grade displays and controls located in the main control room shall be provided for manual, system-level actuation of critical safety functions and monitoring of parameters that support the safety functions.
The displays and controls shall be independent and dilierse from the safety computer system identified in items 1 and 3 above.
The staff's position has been modified in essentially two respects:
First, inasmuch as common mode failures are beyond design-basis events, the analysis of such events should be on a best-estimate basis.
Second, the staff indicates in its discussion of the third part of its position that "The diverse or different function may be performed by a non-safety system if the system is of sufficient quality to perform the necessary function under the associated event conditions."
Therefore, this clarification has been added to the fourth part of the staff's position (which refers to a subset of the safety functions referred to in the third part) by removing the safety grade requirement.
Further, the remainder of the discussion under the fourth part of the staff position is highly prescriptive and detailed (e.g., "shall be evaluated," "shall be sufficient," shall be hardwired,"
etc.).
The Commission approves only that such prescriptiveness be considered as general guidance, the practicality of which should be determined on a case by-case basis.
- 19.
II.R. Steam Generator Tube Ruptures:
II.R.1. Multiple Steam Generator Tube Ruptures:
The Commission approves the staff's position to require that analysis of multiple steam generator tube ruptures (STGRs) involving two to five steam generator tubes be included in the application for design certification for the passive PWRs.
The Commission understands that, as discussed in the Commission meeting on this SECY paper, since the steam generator multi-tube rupture event is beyond the design basis requirements for PWRs, realistic or best-estimate analytical assumptions may be used to assess plant responses.