e e
I VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261
- w. L. STEWART VICE PRESIDENT NucLEAR OPERATIONS September 13, 1985 Mr. Hugh L. Thompson, Jr., Director Office of Nuclear Reactor Regulation Attn:
Mr. Steven A. Varga, Chief Operating Reactors Branch No. 1 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Gentlemen:
Serial No. 85-428A NO/JBL:acm Docket No.
50-281 License No. DPR-37 VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT 2 STEAM GENERATOR GIRTH WELD REPAIR REPORT Enclosed are (40) copies of the final report concerning the Steam Genera-tor Girth Welds for Surry Power Station Unit No. 2.
This report contains information proprietary to Westinghouse Electric Corporation.
Therefore, pursuant to the requirements of 10 CFR 2.790 of the Commission's regulations, we request that this report be withheld from public disclosure.
A Westinghouse affidavit setting forth the basis on which the information may be withheld from public disclosure is attached.
In order for you to make this report available for inspection in the NRG Public Document Room, VEPCO will submit (40) copies of the report with the proprietary information removed.
The non--proprietary reports will be forwarded at a later date.
If you have any questions, or require further information, please contact us:
Very truly yours,
,Jl~
W. L. Stewart Enclosures 1.)
Steam Generator Girth Weld Repair Report (40 copies) 2.")
Westinghouse Affidavit 8509250255 850913 PDR ADOCK 05000281 P
~
e cc:
Mr. Don J. Burke NRC Resident Inspector Surry Power Station Dr. J. Nelson G*race Regional Administrator Region II Mr. Terence Chan NRC Project Manager-Surry Operating Reactor Branch No. 1 Division of Licensing e
e PROPRIETARY INFORMATION NOTICE TR.A.NSMITTE:D*HE:REWlTH ARE PROPRIETARY AND/OR NON-PROPRIETARY VERSIONS OF D0aJH£N1'S ruRNISHD) TO lHE NRC IN CONNECTION WITH REQUESTS FOR cmERIC AND/OR PLANT SPECIFIC REVIEW AND APPROV.AL.
IN OP.DER TO CONFORM TO lHE REQUIREMENTS OF 10CFP.2.7~ OF THE COMMISSION'S EUUTIONS CONCERNING lHE PROTECTION OF PROPRIE!ARY INFORMATION SO SJBMin'ED TO ni£ NRC, lHE ~RHATION WHICH* IS PROPRIETARY IN lHE PROPRIETARY VERSIONS IS CONTAINED WI'IliIN BMCKE:TS AND WHERE: 'lHE PROPRIETARY INFORMATION HAS SEEN DEl.tn:D IN THE NON-PROPRIETARY VERSIONS CM.Y THE BMCKETS REMAIN, 'IHE INFORMATION 'lliAT WAS CONTAINED WnHIN 'l'HE BRACKETS IN lHE P.ROPllETARY VERSION~
HAVING BEEN DEl.ETED.
THE JUSTIFICATION FOR CUIMING niE INFORMATION SO c.;,
DF.SlCNATED AS PROPRIETARY IS INDICATED IN BO'm VERSIONS BY ME:.UJS OF LCWER CASE Lt!TERS Ca) ni.ROUGH Cg) CONTAINED WnHIN PAP.ENTHESF.S LOCAT£D AS A SJPERSCRIPT
~DIAm..Y FOU.CWING THE BRACKETS ma.asING EAeH nEM OF INFORMATION BEING IDE:NnraD AS PROPRIETARY OR IN 'l'HE MARGIN OPPOOITE SJCH INFORMATION.
THESE LQrJER CASE LmERS REFER TO lHE TYPES OF INFORMATION WESTINGHOUSE aJS'l'OMARil.Y HOI.DS IN CONFIDENCE IDE:NTiraD IN SECTIONS (4)(11)(a) through (4)(11)(g) OF THE
(
.AFfIDAVn ACCOMPANYING nus TIWSMITTAI. PURSJANT m 10CFP2.790(b)( 1).