85-510, GL-85-12, NUDOCS 8508290106
Download: ML18143B434 (2)


Text

r.,

e e

VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 W. L. STEWART VICE PRESIDENT NUCLEAR OPERATIONS August 21, 1985 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Attn:

Mr. Hugh L. Thompson, Jr., Director Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION NORTH ANNA POWER STATION RESPONSE SCHEDULE TO GENERIC LETTER 85-12 AUTOMATIC TRIP OF REACTOR COOLANT PUMPS Serial No.

NO/ETS/acm Docket Nos.

License Nos.85-510 50-280 50-281 50-338 50-339 DPR-32 DPR-37 NPF-4 NPF-7 Generic Letter 85-12, dated June 28, 1985, requested a schedule for submittal of the information requested in section IV of your Safety Evaluation (SE) for Westinghouse Owners Group Reactor Coolant Pump Trip.

This letter is to confirm that Virginia Electric and Power Company endorses the WOG methodology and to provide the requested schedule.

The requirements of paragraph IV A., "Determination of RCP Trip Criteria,"

and of paragraph IV B., "Potential Reactor Coolant Pump Problems," will be developed by our Engineering and Construction Department. The results of the responses to paragraphs IV A and B will then be utilized to develop the requirements of paragraph IV C., "Operator Training and Procedures (RCP Trip)."

We will forward the requested information contained in paragraphs IV A, Band C of your Safety Evaluation by February 15, 1986.

If you have any question or require additional information please contact us.

Very truly yours, Ulfi W. L. Stewart

\\

.\\

e VIRGINIA. ELECTRIC AND POWER COMPANY TO Mr. Harold R. Denton cc:

Dr. J. Nelson Grace Regional Administrator Region II Mr. S. A. Varga, Chief Operating Reactors Branch No. 1 Division of Licensing Mr. E. J. Butcher, Acting Chief Operating Reactors Branch No. 3 Division of Licensing Mr. D. J. Burke NRC Resident Inspector Surry Power Station Mr. M. W. Branch NRC Resident Inspector North Anna Power Station Page 2