ML18143B416

From kanterella
Jump to navigation Jump to search
Application for Amends to Licenses DPR-32 & DPR-37,revising Tech Specs to Add New Requirement to Limit Reactor Coolant Min Temp for Criticality to No Less than 522 F During Facility Operation.Fee Paid
ML18143B416
Person / Time
Site: Surry  
Issue date: 08/09/1985
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton, Varga S
Office of Nuclear Reactor Regulation
Shared Package
ML18143B417 List:
References
NUDOCS 8508270042
Download: ML18143B416 (3)


Text

-

WU.LMM L STEWART Vice President Nuclear Operations August 9, 1985 e

Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Attn:

Mr. Steven A. Varga, Chief Operating Reactors Branch No. 1 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Gentlemen:

VIRGINIA POWER SURRY POWER STATION UNITS NOS. 1 AND 2 PROPOSED TECHNICAL SPECIFICATIONS CHANGES Nuclear Operations Department Post Office Box 26666 One James River Plaza Richmond, Virginia 23261 VIRGINIA POWER Serial No.85-499 E&C/NAS/acm Docket Nos. 50-280 50-281 License Nos. DPR-32 DPR-37 Pursuant to 10CFR50.90, Virginia Power requests an amendment, in the form of changes to the Technical Specifications, to Operating Licenses Nos. DPR-32 and DPR-37 for Surry Power Station, Unit Nos. 1 and 2.

The proposed change would add a

requirement to Section 3.1.E of the Specifications, which defines the minimum reactor coolant temperature for criticality.

The new requirement, which would limit the minimum temperature to no less than 522°F, will provide added assurance that the actual conditions achieved during operations are bounded by the range of conditions assumed in the safety analysis, as required by Section 6.6.2.a(8) of the Specifications.

The proposed changes have been reviewed and approved by the Station Nuclear Safety and Operating Committee and by the Safety Evaluation and Control Staff.

It has been determined that this request does not pose any unreviewed safety question as defined in 10CFR50. 59 nor does it pose a significant hazards consideration as defined in 10CFR50.92, We have evaluated this request in accordance with the criteria in 10CFR170.12.

A check in the amount of $150 is enclosed as an application fee.

Very truly yours, di.ff;?

~---------------------

i 8508~70042 8.50809

PDR

'ADOCK 05000280 I p PDR

Attachments:

1.

Proposed Technical Specification Change

2.

Discussion of Proposed Technical Specifications Change

3.

Voucher Check for $150 cc:

Dr. J. Nelson Grace Regional Administrator Mr. Charles Price Department of Health 109 Governor Street Richmond, Virginia 23219 Mr. D. J. Burke NRC Resident Inspector Surry Power Station VIRGINIA POWER

COMMONWEALTH OF VIRGINIA)

)

CITY OF RICHMOND

)

The foregoing document was acknowledged before me, in and for the City and Commonwealth aforesaid, today by W.

L.

Stewart who is Vice President -

Nuclear Operations, of Virginia Power.

He is duly authorized to execute and file the foregoing document in behalf of that Company, and the statements in the document are true to the best of his knowledge and belief.

Acknowledged before me this l\\

day of f\\ u "Ju "".\\-

., 19

~ s-My Commission expires:

/

(SEAL)

S/001