Advises That Future Plant Analyses Will Use Notrump Code for Completion of TMI Items II.K.3.30 & II.K.3.31,per Generic Ltr 83-35.Westinghouse Owners Group Will Provide Analyses of Notrump Model by 860521
ML18143B316
Person / Time
Site: Surry, North Anna, 05000000
Issue date: 07/26/1985
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton, Thompson H
Office of Nuclear Reactor Regulation
References
TASK-2.K.3.30, TASK-2.K.3.31, TASK-TM GL-83-35, NUDOCS 8508010287
Download: ML18143B316 (2)


Text

WlLL/AML STEWART Vice President Nuclear Operations July 26, 1985 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Attn:

Mr. Hugh L. Thompson, Jr., Director Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Nuclear Operations Department Post Office Box 26666 One fames River Plaza Richmond, Virginia 23261 VIRGINIA POWER Serial No.85-524 GLD: vdu:

2005N Docket Nos.:

50-280 50-281 50-338 50-339 License Nos.: DPR-32 DPR-37 NPF-4 NPF-7 USE OF NOTRUMP TO SATISFY TMI ACTION ITEMS II.K.3.30 AND II.K.3.31 NORTH ANNA UNIT NOS. 1 AND 2 SURRY UNIT NOS. 1 AND 2 Gentlemen:

In letters dated May 24 and June 4, 1985 regarding Surry and North Anna, respectively9 your staff requested confirmation of Virginia Power plans and schedule for completion of TMI Action Items II.K.3.30 and II.K.3.31.

This letter provides the requested information for the Surry and North Anna Power Stations.

Virginia Power is a member of the Westinghouse Owners Group (WOG), which has referenced NOTRUMP as their new licensing small break LOCA model.

Future analyses performed for the Surry and North Anna plants will use the NOTRUMP code. This completes TMI Action Item II.K.3.30 for Surry Unit Nos. 1 and 2 and North Anna Unit Nos. 1 and 2.

The WOG has established a program to provide the NRC analysis results using the NOTRUMP code as a generic resolution of TMI Action Item II.K.3.31. This approach was proposed in NRC Generic Letter No. 83-35, dated November 2, 1983.

Virginia Power, as a member of the WOG, intends to reference the generic WOG analyses as applicable to the Surry and North Anna plants.

The proposed WOG plan is to perform a complete break

.-----spectrum for one plant type, and a reduced cold leg break spectrum for

/,,,,-------

other plant types.

The objective of this program is to demonstrate on a generic basis the conservatism of the existing WFLASH analyses with respect to the NOTRUMP evaluation model results.

The results of these analyses are currently scheduled to be submitted to the NRC as a WCAP

-*-report by May 21, 1986.

I

'-..;;_J.

Mr. Harold R. Denton, Director Page 2 e

VIRGINIA POWER Should you have any further questions, please contact us at your earliest convenience.

Very truly yours,

~\\-\\~Jh r

W. L. Stewart Dr. J. Nelson Grace cc:

Regional Administrator-Region II Atlanta, GA 30323 Mr. Steven A. Varga, Chief Operating Reactors Branch No. 1 Division of Licensing Mr. Edward J. Butcher, Acting Chief Operating Reactors Branch No. 3 Division of Licensing Mr. Leon B. Engle NRC Project Manager-North Anna Operating Reactors Branch No. 3 Division of Licensing Mr. Terence Chan NRC Project Manager-Surry Operating Reactors Branch No. 1 Division of Licensing Mr. M. W. Branch NRC Resident Inspector North Anna Power Station Mr. D. J. Burke NRC Resident Inspector Surry Power Station