On the Unacceptability of the 25 F Embrittlement Exclusion in the Beltline Region TLR (TLR-RES/DE/CIB-2013-01)
Allen Hiser Office of Nuclear Reactor Regulation Division of Materials and License Renewal Materials Information Exchange Meeting May 22, 2018 Rockville, MD
Topics
- TechnicalLetterReports
- TLRRES/DE/CIB201301
- PerspectiveRelatedtoExcludingT<25F 2
Issue
- Industryhastakenaconclusionstatement(relatedto exclusionofirradiationembrittlementeffectsforT<25F) fromanREStechnicalletterreport(TLR)andimplemented itinplantspecificlicenseamendmentrequestsanda genericreportasifitisanacceptableNRCstaffposition
- AstheNRChasbeguntoissuerequestsforadditional informationontheuseofthisproposal,therehasbeen confusionbytheindustryonwhyitsuseisnotacceptable
- TheNRCapprovedonelicenseamendmentrequest(LAR) withthisproposal,whichinthiscasedidnotaffectthe acceptabilityoftheLAR
- Thesafetyevaluationdidnotexplicitlyaddressthe unacceptableuseoftheT<25Fexclusion 3
ClarificationofTLRs-Purpose,ProcessesandSignificance
- PurposeofRESTechnicalLetterReports(TLRs):
- ProvideastatusupdatetoNRRforresearchprojectsonce acriticalmilestonehasbeenachievedtodocument researchfindings,surveys,stateoftheartassessments, dataanalysis,etc.
- Documentonepartofalargeresearchprojectthatwillbe integratedwithothers
- Morecompleteorimportantinformation,including conclusionsandincorporatingNRRreviewcomments, generallyarepublishedindocumentssuchasformal NUREGandNUREG/CRreports 4
ComparisonswithNUREGReports ProcessforNUREGsisestablished,structuredandgenerally includesextensiveinternalreview-publicationisasignificant agencyaction
- NocomparableformalreviewandissuanceprocessforTLRs
- UseofTLRsfacilitatesexpeditedcommunicationoffindings NUREGsincludedisclaimerstatementand(forRESreports)a Forewordtoprovidecontexttothereport
- TLRsincludenocomparableprovisions Historically,NUREGshavebeenoneoftheprimarymeansofNRCs communication
- MorerecentpostingofTLRsaspublicinADAMSenableseasyaccess
- Thishascreatedconfusionontheacceptability,relevanceandutilityof resultsmadepublicinTLRs 5
NRCStaffRegulatoryPositions
- NRCstaffregulatorypositionsareprovidedin regulations,regulatoryguidesandotherformal documentslabeledassuch
- Ingeneral, statementsinNUREGreports,NUREG CRs,TLRsarenot NRCstaffregulatorypositions
- ExceptionsincludetheGALLandGALLSLR reports,whichprovideguidanceonacceptable agingmanagementprogramsforlicenserenewal andSLR,respectively 6
TLRonRPVBeltline
- TLRRES/DE/CIB201301,"EvaluationoftheBeltlineRegion forNuclearReactorPressureVessels,(ML14318A177)
- IssuedNovember14,2014
- Oneofaseriesofplannedtechnicalletterreportsplannedby REStosupportapossible10CFRPart50,AppendixG rulemaking
- AsstatedinSection4,theRESstaffrecommends:
- Embrittlementeffectsmaybeneglectedforanyregionofthe RPVifeitherofthefollowingconditionsaremet:
1) neutronfluenceislessthan1x1017 n/cm2 (E>1.0MeV)atEOL,or 2) themeanvalueofT30 estimatedusinganETC[embrittlement trendcurve]acceptabletothestaffislessthan25°FatEOL.The estimateofT30 atEOLshallbemadeusingbestestimatechemistry values.
Item1)isconsistentwithRegulations-notanissue.
Item2)isnotconsistentwithRegulations-abasisforthis provisionisnotprovidedintheTLR.
7
RegulatoryIssueSummary201411 InformationonLicensingApplicationsforFractureToughness RequirementsforFerriticReactorCoolantPressureBoundary Components IssuedOctober14,2014 toprovideguidance...onthescopeanddetailofinformationthat shouldbeprovidedinreactorvesselfracturetoughnessand associatedpressuretemperature(PT)limitslicensingapplications allferriticcomponentswithintheentirereactorvesselmustbe consideredinthedevelopmentofPTlimits,andtheeffectsof neutronradiationmustbeconsideredforanylocationsthatare predictedtoexperienceaneutronfluence exposuregreaterthan 1x1017 n/cm2 (E>1MeV) attheendofthelicensedoperating period.
Nodiscussionregardingexclusionofembrittlementeffectsif T30is lessthan25°F.
8
25FTLRRecommendation
- Basisisnotclearlypostulated,discussednor supportedintheTLR-firststatedinthe summaryofresultswithoneaccompanying graph
- Conflictswithrelevantregulationsandnot consistentwithRIS201411 9
RelevantRegulations 10CFR50AppendixG,II.F-BeltlineorBeltlineregionofreactor vesselmeanstheregionofthereactorvessel...thatarepredicted toexperiencesufficientneutronradiationdamagetobeconsidered intheselectionofthemostlimitingmaterialwithregardto radiationdamage 10CFR50AppendixH,III.A-Nomaterialsurveillanceprogramis requiredforreactorvesselsforwhich...thepeakneutronfluence attheendofthedesignlifeofthevesselwillnotexceed1017 n/cm2 (E>1MeV).
10CFR50AppendixG,IV.A-Forthereactorvesselbeltline materials,includingwelds,platesandforgings,thevaluesofRTNDT andCharpy uppershelfenergymustaccountfortheeffectsof neutronradiation 10
MoreRelevantRegulations 10CFR50.61-PTSRule
- (a)(3)ReactorVesselBeltlinemeanstheregionofthereactorvessel...
thatarepredictedtoexperiencesufficientneutronradiationdamageto beconsideredintheselectionofthemostlimitingmaterialwithregardto radiationdamage-samedefinitionas10CFR50,AppendixG
- (a)(4)RTNDT meansthereferencetemperatureforareactorvessel material,underanyconditions.Forthereactorvesselbeltlinematerials, RTNDT mustaccountfortheeffectsofneutronradiation
- (a)(7)RTPTS meansthereferencetemperature,RTNDT,evaluatedfortheEOL Fluenceforeachofthevesselbeltlinematerials,usingtheproceduresof paragraph(c)ofthissection
- (c)(1)(iv) RTNDT isthemeanvalueofthetransitiontemperatureshift,or changeinRTNDT,duetoirradiation,andmustbecalculatedusingEquation 3.
11
MoreRelevantRegulations
- 10CFR50.61a-AlternatePTSRule
- (a)Termsinthissectionhavethesamemeaningasthose presentedin10CFR50.61(a),withtheexceptionoftheterm ASMECode.
- (c)(1)EachlicenseeshallhaveprojectedvaluesofRTMAX-X for eachreactorvesselbeltlinematerialfortheEOLfluenceof thematerial. TheassessmentofRTMAX-X valuesmustusethe calculationproceduresgiveninparagraphs(f)and(g)ofthis section.
12
MoreRelevantRegulations
- 10CFR50,AppendixH
- (I)thetestproceduresandreportingrequirements mustmeettherequirementsofASTME18582to theextentpracticable...
- ASTME18582
- 10.2.1Determinetheradiationinducedtransition temperatureshiftsbymeasuringthedifferencein the41J(30ftlbf)...indextemperaturesbefore andafterirradiation.Theindextemperaturesshall beobtainedfromtheaveragecurves.
13
RegulatoryGuide1.99,Rev.2 RadiationEmbrittlementofReactorVesselMaterials
- Theadjustedreferencetemperature(ART)for eachmaterialinthebeltlineisgivenbythe followingexpression:
- ART=InitialRTNDT +RTNDT +Margin(1)
- RTNDT isthemeanvalueoftheadjustmentIn referencetemperaturecausedbyirradiationand shouldbecalculatedasfollows:
- RTNDT =(CF)f(0.280.10logf) 14
Perspective-Part1
- RESTLRandRISwereunderdevelopmentduring thesametimeframe.
- The25°Frecommendationwasincludedinthe RESTLRasaconsiderationbytheRESstaff-the regulatorypositionespousedintheRIS specificallydidnotincludethisprovision.
- ApubliccommentonGALLSLRRPVmaterial surveillanceprogramguidancerecommended implementationofthe25°Fexclusion-this recommendationwasrejectedbythestaff.
15
TechnicalAssessment
- HighestART(andpotentialnozzlestresses)definePTlimit curves
- ART=InitialRTNDT +RTNDT +Margin
- Changingshiftsofupto25°Fto0°Fresultsindecreasing ARTbyupto50°F,byalsoreducingthemarginterm.This canbeasignificantchange.
- Incertaincases,the25°Fproposalmayimpact identificationoflimitingmaterialsforART,resultingin developmentofincorrect(nonconservative)PTlimits.
- Relatedbutnotdeterminativeitem-Researchprograms examiningneutronfluence(revisionofRG1.190)indicate thatfluenceprojectionsforextendedbeltlinematerialsand nozzlesmaybeunderpredicted;RTNDT wouldincreasefor thesematerials.
16
SummaryofRegulatoryProvisionsand TechnicalAssessment
- Relevantregulationsstatethatcalculationsmustaccount forradiationeffectsforthosematerialswithfluencegreater than1017 n/cm2 (E>1MeV),asdescribedinRIS201411.
- Noprovisioninanyoftheregulationspermitsexclusionof RTNDT orT30 lessthan25°F.
- AcceptanceoftheTLRproposalcouldresultinplant operationwithnonconservativePTlimits(AppendixG violation).
- Currentview:
Disalloweliminationofembrittlementeffects ifRTNDT orT30 lessthan25°F 17
Perspective-Part2 Regulationsrelatedtoreactorpressurevesselintegritydonot permitexclusionofRTNDT orT30 lessthan25°F.
TLRdoesnotprovideanadequatetechnicalbasisforanexemption fromtheregulatoryrequirements.
UseofallRTNDT orT30(even<25°F)isaconservativepositionto estimateRPVtoughness,whichhasbeenalongstandinggoal.
Plantsubmittalsandtopicalreportsshouldnotusethisprovision withoutanadequatetechnicalbasistosupportanexemption requestorstaffapproval,asrequired.
Forpriorsubmittalsandindustrytopicalreports:
- IftheresultingPTlimitsremainunchanged,supplementwiththe correctARTvalueforeachRPVbeltlinematerial.
- IftheresultingPTlimitschange,needtoensurethatthecorrectART valueforeachRPVbeltlinematerialareusedtorevisePTlimitsinthe LAR,andtheplantspecificapplicationreport.
18
Conclusions
- TLRisnotanacceptablebasisforneglecting embrittlementeffectsifRTNDT orT30 less than25°F.
- CurrentNRCpositionisdescribedinRIS 201411:RPVtoughnesscalculationsmust accountforradiationeffectsforthose materialswithfluencegreaterthan1017 n/cm2 (E>1MeV),withoutexclusionevenif RTNDT orT30 lessthan25°F.
19
Conclusions
- Asalways,NRCstaffispreparedtoreview anyindustryproposalwhichprovidesan adequatetechnicalbasisfortheproposal.
20