ML18139B846

From kanterella
Jump to navigation Jump to search
Ro:On 820403,average Rate of Change of Condenser Cooling Water Outlet Temp Exceeded Permitted Rate.Caused by Operator Error.Personnel Reinstructed
ML18139B846
Person / Time
Site: Surry  
Issue date: 04/16/1982
From: Leasburg R
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton, Varga S
Office of Nuclear Reactor Regulation
References
229, NUDOCS 8204190218
Download: ML18139B846 (1)


Text

VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND.., VIRGINIA 23261 R.H.LEASBUBG VxcE PREsXDENT NucLEAR OPERATIONS April 16, 1982 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Attn:

Mr. Steven A. Varga, Chief Operating Reactors Branch No. 1 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Gentlemen:

Serial No. 229 NO/RMT:acm Docket Nos. 50-280 50-281 License Nos. DPR-32 DPR-37 This letter report is furnished in accordance with the provisions of Surry Power Station Technical Specification 4.14.C.1.

During the period of 1000 hours0.0116 days <br />0.278 hours <br />0.00165 weeks <br />3.805e-4 months <br /> to 1100 hours0.0127 days <br />0.306 hours <br />0.00182 weeks <br />4.1855e-4 months <br />, April 3, 1982, the average rate of change of the Condenser Cooling Water Outlet Temperature was 4°F/hr. which exceeds the 3°F/hr. rate of change permitted by Technical Specification 4.14.A.3.

At the time of this event, Unit 1 was at 100% power and Unit 2 was at 95%

power.

After removal of Unit 1 "C" water box from service for cleaning a seventh circulating water pump was started.

In response to an increasing canal level the the water box outlets were throttled opened and the groin temperature dropped at a rate greater than 3°F/hr.

The operator then stopped water box throttling to allow groin temperature to stabilize.

Personnel involved have been re-instructed on the importance of making gradual changes in flow through the water boxes.

A search was conducted to determine if the temperature change had affected the river environment.

No detrimental evidence was found.

cc:

Mr. James P. O'Reilly Regional Administrator Region II 0~.-8204190218 820416 -

.:.. PDR ADOCK 05000 280

(.:*:*.$)*:;.. ;.. /,.;,;.. ::,

  • . *.,:.,,:/'*...-..,,PP~ *:*Y:

Very truly yours,

. Q\\_~\\-

l R. H. Leasburg