ML18139A735

From kanterella
Jump to navigation Jump to search
Forwards LER 80-042/03L-0
Date released: 12/10/2018 Download: ML18139A735


LER 80-042/03L-0:on 800805,pump for Drawing Radiation Samples from Process Vent Sys Froze & Triggered Low Flow Alarm.Caused by Moisture Condensation in Pump Area.Pump Pulled & Replaced
ML18139A736
Person / Time
Site: Surry 
Issue date: 08/05/1980
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18139A736 (2)
Forwards LER 80-042/03L-0
ML18139A733
Person / Time
Site: Surry 
Issue date: 09/05/1980
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18139A733 (1)