877~~7 SH 11 K
03 Z
(3Z 716929.
Q 1195
~ 2 H
AUX.STEAN 25000 8/HR 211 '
P 1110-3 NOISTURE SEPARRTOR Ol c
ID CI o
REHEATER <<I 198-6 P
498 F 9 F
1268.6 H
198.6 P
464
~ 1 F
1249
~ 0 H
6216136 '
8288015 '
(0 I
2 (II Z p
()
0)
Z COz z0:-
)
E I
11786901()
885 '
P 1195.2 H
0
~ 252 STERN GEN 27Q8.4 NNT I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
J I
I I
I I
I I
I I
I I
- -8
[I[
I I
I I
I I
I I
I 2'-a
[o oo CI z 'o o IO
[ID CD I
I I
432 'F 411
~ 3H 11040849. 0 851
~ 3 P
1195
~ 2 H
0
~ 402 8508.
0 312 '
1110
~ 3 H
cc)Z A.Iu IL' I
IDI I
cc t'
I I
t t
F)I-HTR <<5 5 -6 FTD SG-F
~ P
~
I I
F)I.HTR <<4 5
6 FTD 1620760C 11920760 0 3g L3g ~
Pl
.gF 437.9 F
10 ~ 0 D.C-206
~ 5 384.5 09 '
F 309.7F 80 '
H I
279
~ 7H I
I I
I I
I I
I g 1444734 4) 390 '
F 364 '
H
,'3453532 0 384.5 F
I 358 '
H HIGH PRESSURE TURBINE EXTRACTIONS AND LEAKS ARE SYNNETRICAL I
Ol cnl
[DI CT[o I
I ol I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I DRAIN COOLER 32.0 0 ~ C 278 SF 247 ASH
'3453532 0 3105 F
280.5H I
HTR ~ DR PUNP c
ID Cl I
'I o>
ID[
I I
o[
I I
CD[
OA I
I I
I 2072045.
0 1
I oPu Jo
~ID F F)I.MTR <<3
[(5 ~ 6 FTD
.lo 3=:
FN.HTR <<2 I 5.6 FTD 52 '
P 284 '
F 10 '
O.C-224 'F 192 'H 20.72 P
229.9 F
11 '
D AC.
180
~ BF 148
~ BH I
I I
I 484901.
0 235.1 F
203.5 H
I I
I I
4, 874123
~ 0 191
~ 8 F 159.8 H
I
!!90.2 H
(I OF 4 rsRS QUT)
I I
I I
I I
I I
I I
I I
I I
I I
I STEAN SEAL REGULRTOR 82880(ST Q
194 '
P TAO SCHENATIC DOUBLE FLON L-P-TURBINES EXTRACTIONS AND LEAKS ARE SYNtlETR ICAL BQNL PRESSURE 194.6 I
I d
~~
cJ a
I cu i
I 1a Id I
a I
I I
I I
I I
I I
I I
I I
I I
DID~
FN.HTR <<I 6 ~ 6 FTO 8-83 P
187-4 F
11 '
0 ~ C-I I
I I
+ 147)19547 121
~ 6 F 89
~ 5 H
I I
I I
I I
6713770 '
95.2 H
56099
~
C 122.9 H
5[129. 0
[021
~ 6 H CI 1177
~ 2 H
GENERATOR OUTPUT 899930-KN NL<<
3045 ')I GL=
10709 J(N RT 60
~ PSIG H2 CONDENSER BP ELEP CEP INHG ~
H H
2-53 96' 976-1 367228.0 109.1 F
77 '
H PUNP COND SJAE
[109 '
H (77 5F I
I I
I I
A GSC
!110.0 H
I 78
~ 0 F
I I
I I
WAKE=UK WJIQ(L BUX COND
~
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I SARTOS ST[FIG J~
CTO RS 39115 STATE OF C DRID Ct"YFX(o 5"~
PEPFQRNRNLE GROSS GENERATION K'Ii ~
899930.
TURBINE HEAT-RATE BTU/KA.HR 10267.3 LEGEND 0--FLQN-LBS/HR F----TENPERATURE-F PPRESSURE-LBS/SOD IN ASST H--ENTHALPY OF STEAN-BTU/LB FTD--TERNI)IAL DIFFERENCE (F)
XLEP-EXPANSION LINE ENO'POINT UEEP-USED ENERGY ENO PDINT D.C.-DRAIN COOLER APPROACH (F)
S.C
~ -SUBCOOLING (F)
SHEET NO II.
IZ,
)3.
THRn TLEF FI Q LBS/HR 11040849
'1270432
'0825821
'HROTTLE PRESSURE PSIA 851 851
'51 IN.HG ABS 2-53 2
~ 53 2 ~ 53 CYl LuuES LBS/HR 18859 18859.
18859'l u
AN LBS/HR 15000 15000
'5000.
NOTES 1
OF 4
NSRS OUT 2
OF 4
NSRS OUT 1
OF 2 HOPS OUT THIS DOCUMENT IS THE PROPERTY OF EBASCO SERVICES INCORPORATED. ITS USE IS EXPRESSLY RESTRICTED BY THE TERMS OF THE CONTRACT, DATED AS OF AUGUST 1D, 1SSS BETWEEN EBASCO SERVICES INCORPORATED AND FLORIDA POWER 3
L%HT COMPANY FLORIDA PONER I( LIGHT CDNPANY ST
~ LUCIE PLANT 1976 890
~ 000 KII INSTALLATION UNIT NO.I HEAT BALANCE 2710 MWT CONSTANT BACK PRESSURE ONE MSR OUT OF SERVICE EBASCO SERVICES INCORPORATED NEN YORK STEAN HATER EXTRACTION STEAN TNO PHASE FLON HAIN PATH NO ~
DATE DRAWING ORIGINALLYAPPROVED AS BCS-[2[FC[L334 SH 1 OF S REVISION BY SCALE-NONE 0 IV ~
DR ~
APPROVED CH ~
APPROVED I/PAs c,
Q Q lV.DSD, 2
5'/B.
8770-C-057 SH 113