Drawing 8770-B-327, Rev. 53, St Lucie Plant-Extension-Unit 1 Control Wiring Diagram Index. Sheet 3
ML18127B308
Person / Time
Site: Saint Lucie 
(NPF-016)
Issue date: 05/11/2001
From:
Ebasco Services
To:
Florida Power & Light Co, Office of Nuclear Reactor Regulation
References
8770-B-327, Rev. 53
Download: ML18127B308 (1)


Text

SHEET NO 311 312 314 315 316 317 318 319 320 321 322 329 331 339 I

346 349 350 351 352 354 355 REV NO REACTOR CONTAINMENT AIR RECIRC UNIT FAN HVS-1A REACTOR CONTAINMENT AIR RECIRC UNIT FAN HYS-18 REACTOR CONTAINMENT AIR RECIRC UNIT FAN HVS-1C REACTOR CONTAINMENT AIR RECIRC UNIT FAN HYS-10 MAIN STEAM ISOL BYPASS MY-081A MAIN STEAM ISOL VALVE HCV-08-lA OPENING & CLOSING MAIN STEAM ISOL VALVE HCV-081A TESTING MAIN STEAM ISOL BYPASS MV-08-18 MAIN STEAM ISOL VALVE HCV08-18 MAIN STEAM ISOL VALVE HCV-08-1B INSTRUMENT AIR ISOLATION VALYE MV-18-1 STEAM GEN BLOWDOWN ISOL YALVES FCV-23-3. FCY-23-5 STEAM GEN SLOWDOWN ISOL VALVES FCY-234, FCV-23-6 CONTAINMENT SAMPLE ISOLATION VALVES S

I T SAMPLING VALVES S

I T SAMPLiNG VALVES MSIS "A" & "8" ISOLATION RELAYS CONT ISOL CH A MAN RESET & MAIN STM ISOL VLV BLOCK A CONT ISOL CH 8 MAN RESET & MAIN STM ISOL VLV BLOCK 8 RADIATION MONITOR CHANNELS 43, 56 & 57 RADIATION MONITOR CABINETS ANNUNOATOR PROCESS RADIATION MONITORING CH 64 AREA RADIATION MONITOR CHANNELS 52 & 53 PROCESS RADIATION MONITOR CHANNELS 46 & 47 PROCESS RADIAllON MONITOR CHANNELS 48 & 50 YOID SUPSO BY SH 348 PROCESS RADIATION MONITOR CHANNELS 46 & 47 PUMP CONTROL 0 A I CHANNELS 46 & 47 SAMPLE SELECTOR SYSTEM PROCESS RADIATION MONITOR CHANNELS 48 & 50 PUMP CONTROL PROCESS RADIATION MONITOR FHB CHANNELS 49, 51 & 55 SGBD TANK VENT RAD MONITOR CH 54 RAD MONITOR PANEL REFLASH UNITS PROCESS RADIATION MONITOR 0 A S RESERVED CONDENSATE RECOVERY RADIATION MONITOR CH 34 RESERVED CCW RADIATION MONITOR CHANNEL 56 & 57 CONTAINMENT Hl-RANGE RAD MONITOR CH 58 & 59 NOBLE GAS RADIATION MONITORS (CT 2)

SHEET REV NO NO 357 359 364 370 371 372 373 374 375 376 378 379 384 390 391 394 395 399 NOBLE GAS RADIATION MONITORS (CT 1)

AREA RADIATION MONITORING LIQUID RADWASTE SYS RADIATION MONITOR PANEL ANN "X" CABINET E NOBLE GAS RADIATION MONITORS (OAM-3)CH 62 & 63 ENGINEERED SAFEGUARDS ANNUNOATOR "S" SH 1 RTGB-106 ENQNEERED SAFEGUARDS ANNUNOATOR "S" SH 2 RTGB-106 ENQNEERED SAFEGUARDS ANNUNOATOR R" SH 1 RTGB-106 ENGINEERED SAFEGUARDS ANNUNOATOR "R" SH 2 RTGB-106 ENQNEERED SAFEGUARDS ANNUNOATOR "Q" SH 1 RTGB-106 ENQNEERED SAFEGUARDS ANNUNOATOR "Q" SH 2 RTGB-106 ENQNEERED SAFEGUARDS ANNUNOATOR "P" SH 1 RTGB-106 ENQNEERED SAFEGUARDS ANNUNCIATOR "P" SH 2 RTGB106 SUBCOOUNG MARQN MONITOR CH "A RESERYED SUBCOOUNG MARQN MONITOR CH "8 RESERVED PRESSURIZER PRESSURE P-1102A MEASUREMENT LOOP PRESSURIZER PRESSURE P-1102B MEASUREMENT LOOP PRESSURIZER PRESSURE P-1102C MEASUREMENT LOOP PRESSURIZER PRESSURE P-1102D MEASUREMENT LOOP STEAM GENERATOR 1A LEVEL STEAM GENERATOR 18 LEVEL STEAM GENERATOR 1A PRESSURE STEAM GENERATOR 18 PRESSURE STEAM GEN lA & 18 LEVEL WIDE RANGE REACTOR COOLANT TEMP CHANNEL T-1112A, T-1122A REACTOR COOLANT TEMP CHANNEL T-11128, T-11228 REACTOR COOLANT TEMP CHANNEL T-1112C, T-1122C REACTOR COOLANT TEMP CHANNEL T-1112D, T-1122D REACTOR COOLANT DELTA FLOW CH P-1101A REACTOR COOLANT DELTA FLOW CH P-11018 REACTOR COOLANT DELTA FLOW CH P-1101C REACTOR COOLANT DELTA FLOW CH P-1101D REACTOR COOLANT PUMPS lA1, 181, 1A2 & 1B2 INTERLOCKS REACTOR PROTECTlON SYSTEM CHANNEL TRIP VOID RTGB-103 & 104, 120V AC & 125V DC DISTRIBUTION RTG8-103, 120V AC MEASUREMENT CHANNEL DISTRIBUTION CEA ANNUNCIATOR "K" RTGB104 REACTOR PROTECTlON ANNUNOATOR L

RTGB-104 SHEET NO 404 406 409 410 411 412 413 414 415 416 417 418 419 422 423 424 426 427 428 429 431 432 434 435 436 437 439 444 446 REV NO CEA DRIYE MG SET 1A CEA DRIVE MG SET 18 RRS CONTROL UNIT SELECTOR SW SH 1

RRS CONTROL UNIT SELECTOR SW SH 2 RRS CONTROL UNIT SELECTOR SW SH 3 REACTOR PROTECTION SYSTEM ALARMS CEA MIMIC DISPLAY1 CEA DRIVE MG SET 1A PANEL CEA DRIVE MG SET 18 PANEL REACTOR TRIP BKR TCB-1 REACTOR TRIP BKR TCB5 REACTOR TRIP BKR TCB-2 REACTOR TRIP BKR TCB-6 REACTOR TRIP BKR TCB-3 REACTOR TRIP BKR TCB-7 REACTOR TRIP BKR TCB4 REACTOR TRIP BKR TCB-8 REACTOR TRIP CKT BKR TCB-9 REACTOR TRIP SWGR UNDERCURRENT DEVICES IN CAB 8 REACTOR TRIP SWGR UNDERCURRENT DEVICES IN CAB C REACTOR TRIP SWGR & CPP CONT CTRS 120VAC & 125VDC DISTR CEAPOS SH 1

CEAPOS SH 2 CEAPDS SH 3 CEAPDS SH 4 CEAPDS SH 5 VOID CEA GROUP OPERATION AND DEYIATION UGHTS SH 1

CEA GROUP OPERATION AND DEVIATION UGHTS SH 2 CEA MIMIC DISPLAY -2 CEA MIMIC DISPLAY -3 CEA MIMIC DISPLAY -4 CEA MIMIC DISPLAY -5 RADIATION MONITORING PNL 120V AC, 125V DC & 120V AC MEAS CH S DISTR AREA RADIATION MONITOR CHANNELS 3 & 4 AREA RADIATION MONITOR CHANNELS 1, 2 & 7 AREA RADIATION MONITOR CHANNELS 8, 9 & 12 AREA RADIATION MONITOR CHANNELS 15, 19 & 21 AREA RADIATION MONITOR CHANNELS 10, 11 & 13 AREA RADIATION MONITOR CHANNELS 16, 17 & 18 AREA RADIATION MONITOR CHANNELS 14, 20 & 22 AREA RADIATION MONITOR CHANNELS 25. 26 & 27 VOID SUPSO BY SH 355 VOID SUPSD BY SH 356 REV DATE BY APPROVED 53 52 51 50 REV 10/IB/94 7/2B/93 9/21/92 DATE BY RJF EBASCO SERVICES INCORPORATED NEW YORK APPROVED R C HAEKLER V.O.

M.M.

RSC DIV: I&C DR:

BT CAA VJC JPP RM DATE: '6 72 APPROVED FLORIDA POWER 8c LIGHT COMPANY ST LUCIE PLANTEXTENSIONUNIT 1

CONTROL WIRING DIAGRAM INDEX 8770- B-327 SHEET 3 FILE: USC00016