Drawing 8770-B-327, Rev. 52, Extension - Unit 1 Control Wiring Diagram Index. Sheet 7
ML18127B291
Person / Time
Site: Saint Lucie 
(DPR-067)
Issue date: 04/25/2006
From:
Florida Power & Light Co
To:
Office of Nuclear Reactor Regulation
References
8770-B-327, Rev 52
Download: ML18127B291 (1)


Text

EV 0

SHEET R

HO H

SHEET REV NO NO TITLE SHEET NO REV NO 890 891 892 893 894 695 896 897 898 899 901 902 903 904 905 907 908 909 910 911 912 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 PRIMARY/UNDERFREQUENCY GENERATOR LOCKOUT RELAYS PRIMARY GENERATOR LOCKOUT RELAY 1

PRIMARY BACK-UP GENERATOR LOCKOUT RELAYS BACK-UP GENERATOR LOCKOUT RELAY GENERATOR BREAKERS 1E dc IM LOAD FREO CONTROL RACK INTERCONNECTIONS GENERATOR AUTO dr MAN SYNCHRONIZING AUXIUARY SYNCHRONIZING GENERATOR k TRANSFORMERS TEMP RECORDER TR-22-30 (GENERATOR COHTINUED OH 1790)

UNE REPEAT PANEL ANNUNOATOR 240 KV BREAKERS 1W, 2M. & 2W MOTOR OPERATED DISCONNECT SNTCHES gl. f2, g5 & g7 MIDWAY fl METERING MIDWAY g2 METERING & MISC. ALARMS SWYD SYH LINE REPEAT PNL VOID VOID PRIMARY GEN LOCKOUT RELAY3 START-UP STANDBY TRANSFORMER IA DIFF RELAY STARTUP STANDBY TRANSFORMER 1A LOCKOUT RELAY START-UP STANDBY TRANSFORMER 18 DIFF RELAY STARTUP STANDBY TRANSFORMER 18 LOCKOUT RELAY START-UP TRANSFORMER 1A1 BREAKER START-UP TRANSFORMER 181 BREAKER STARTUP TRANSFORMER 1A2 BREAKER I

STARTUP TRANSFORMER 182 BREAKER START-UP STANDBY TRANSFORMERS 1A & 1B UNIT AUXIUARY TRANSFORMER 1A & 1B UNIT AUX TRANSF lA DIFF RELAYING & GRD RELAYING UNIT AUX TRANSF-IB DIFF RELAYING & GRD RELAYING UNIT AUX TRANSF IA1 BREAKER UNIT AUX TRANSF 181 BREAKER UNIT AUX TRANSF IA2 BREAKER UNIT AUX TRANSF 1B2 BREAKER 4160V SWGR 1A2 METERING 4160V SWGR 182 METERING 6900V SWGR 1A1 METERING 6900V SWGR 181 METERING 6900V SWGR 1A1 DIFF RELAY 6900V SWGR 181 DIFF RELAY 4160V SWGR 1A2 DIFF RELAY 4160V SWGR 182 DIFF REI AY 4160V SWGR 1A3 DIFF RELAY 4160V SWCR 183 DIFF RELAY 4160V SWGR 1AB DIFF RELAY 6900V SWGR IA1 ACDC DISTR & HEATERS 6900V SWGR 1B1 ACDC DISTR & HEATERS 4160V SWGR 1A2 AC-DC DISTR & HEATERS R52-PCM 00077 930 931 932 933 934 935 936 937 939 940 941 942 943 944.

945 947 948 949 950 951 952 953 955 956 957 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 REV DATE BV 460V SWGR SPACE COMPARTMENTS 480V SWGR lA1 ~

181 TIE 480V SWGR 181 FDR 48CV SWGR lA2 FDR 480V SWGR lA2, 1AB TIE 460V SWGR 1AB, 1A2 TlE 480V SWGR 182 FDR 480V SWGR 182.

1AB llE 480V SWGR 1AB, 182 TIE 480V SWGR SPARE COMPARTMENTS 460V SWGR 1A2 FDR TO FUEL HANDUNG MCC 1A8 480V SWGR 182 FDR TO FUEL HANDUNG MCC 188 480V SWGR lA1 MET REL & HTR S 480V SWGR 1A1 MCC FEEDERS 480V SWGR 181 MET. REL & HTR S 460V SWGR 181 MCC FEEDERS 480V SWGR lA2 MET, REL & HTR'S 480V SWGR 1A2 MCC FEEDERS 480V SWGR 1B2 MET, REL & HTR'S SH 1

480V SWGR 182 MCC FEEDERS 460V SWGR lAB MET, REL & HTR'S 460V SWGR lAB FEEDER TO REACTOR AREA MCC 1AB EMERGENCY DIESEL GEN NO 1A LOADING LIGHTS EMERGENCY DIESEL GEN NO 18 LOADING LIGHTS EMERGENCY DIESEL GEN'S NO 1A & NO IB LOADINC LIGHTS BATTERY 1C & BATTERY CMARCER 1C 125V DC BUS TRANSFER CONTROL BATTERY 1A & BATTERY CHARGER 1A BATTERY 18

  • BATTERY CHARCER 1B BATTERY CHARGER 1AB SWITCHYARD BATTERIES A & B & BATTERY CHARGERS A, B. & AB MOTOR SPACE HEATER FEEDERS
CCWP, ICWP THIRD PUMP INTERLOCKS MISC ANNUNCIATIONS RTCB 102 VITAL AC BUS POWER SUPPLY INSTRUMENT BUSES & INVERTERS 1MA k 1MC INSTRUMENT BUSES & INVERTERS 1MB & 1MD 480V MCC 1A5 NON ESSENTIAL LOADS BREAKER 460V MCC 1A6 NOH-ESSENTIAL LOADS BREAKER 480V MCC 185 NON-ESSENTIAL LOADS BREAKER 480V MCC 186 NQN-ESSENTIAL LOADS BREAKER 480V MCC 1A8 NON-ESSENTIAL LOADS BREAKER 480V MCC 1B6 NON ESSENTIAL LOADS BREAKER SWITCHYARD 480V AC SUPPLY EBASCO SERVICES INCORPORATED NEW YORK FLORIDA POWER 8c LIGHT COMPANY ST LUCIE PLANTEXTENSION UNIT 1

CONTROL WIRING DIAGRAM APPROVED R

C HAEKLER INDEX V,O.

M.M.

4160V SWCR 182 AC-DC DISTR & HEATERS 4160V SWGR lA3 ACDC DISTR & HEATERS 4160V SWGR 183 AC-DC DISTR & HEATERS 4160V SWGR 1AB ACDC DISTR & HEATERS 4160V SWGR 1A2 FDR TO BUS 1A3 4160V SWGR 1B2 FDR TO BUS 183 4160V SWGR 1A3 INCOMING FEEDER FROM BUS 1A2 4160V SWCR 183 INCOMING FEEDER FROM BUS 182 4160V SWGR lA3 FDR TO BUS 1AB 4160V SWGR 182 FDR TO BUS lAB 4160V SWCR 1AB INCOMING FOR FRDM BUS 1A3 4160V SWGR 1AB INCOMING FDR FROM BUS 183 4160V SWGR 1AB RELAYING & METERING PRESS HTR TRANSF 1A3 4160V FDR BKR PRESS HTR TRANSF 183 4160V FDR BKR 480V SWGR 1A1 4160V FDR BKR 480V SWGR 1A2 4160V FDR BKR 460V SWGR 181 4160V FDR BKR 480V STA SERV XFMR 1B2 4160V FOR BKR 4160V SWGR 1A3 LOAD SHEDDING RELAYS 4160V SWGR 183 LOAD SHEDDING RELAYS 4160V SWGR 1AB LQAD SHEDDING RELAYS 6900V SWGR 1Al & 181

& 4160V SWGR 1A2 & 182 UNDERVOLTAGE RELAYING DIESEL GENERATOR 1A BREAKER DIESEL GENERATOR lA RELAYING & METERING DIESEL GENERATOR 1A GRD & DIFF RELAYING DIESEL GENERATOR 1A LOCKOUT RELAY DIESEL GENERATOR 1A START CKT'S DIESEL GENERATOR 1A REMOTE CQNTROI DIESEL GENERATOR 1A-START SOLENQIDS DIESEL GENERATOR 1A-ANN EXT WIRING DIESEL GENERATOR 1A-ANN FRONT VIEW DIESEL GENERATOR 1A EXHAUST DIFFERENTIAL TEMPERATURE ALARM DIESEL GENERATOR 18 BREAKER DIESEL GENERATOR 1B RELAYING & METERING DIESEL GENERATOR 18 GRD & DIFF RELAYING DIESEL GENERATOR 1B LOCKOUT RELAY DI SEL GENERATOR 18 STA T CKTS DIESEL GENERATOR 1B REMOTE CONTROL VOLTAGE DIESEL GENERATOR 1B START SOLEN S

DIESEL GENERATOR 18 ANN EXT WIRING DIESEL GENERATOR 18 ANN FRONT VIEW DIESEL GENERATOR 1B EXHAUST DIFFERENIlAL TEMPERATURE ALARM 480V SWGR lA1 FDR 8/21/96 7/26/93 9/21/92 DATE TW MZ RFR JPP R F RSC CAA VJC 50 DR:

BT DIV: l&C RM DATE 05 26 2

APPROVED REV BY APPROVED R.L.

975 974 976 977 978 979 980 981 982 983 965 984 986 987 988 969 990 991 992 993 994 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1006 1009 1010 1011 1012 1013 1014 1015 1016 1017 8770- B-327 SHEET 7