ML18121A459

From kanterella
Jump to navigation Jump to search
SMR DC RAI - Request for Additional Information No. 454 Erai No. 9499 (15)
ML18121A459
Person / Time
Site: NuScale
Issue date: 05/01/2018
From:
NRC
To:
NRC/NRO/DNRL/LB1
References
Download: ML18121A459 (3)


Text

1 NuScaleDCRaisPEm Resource From:

Chowdhury, Prosanta Sent:

Tuesday, May 1, 2018 4:24 PM To:

Request for Additional Information Cc:

Lee, Samuel; Cranston, Gregory; Franovich, Rani; Karas, Rebecca; Schmidt, Jeffrey; NuScaleDCRaisPEm Resource

Subject:

Request for Additional Information No. 454 eRAI No. 9499 (15)

Attachments:

Request for Additional Information No. 454 (eRAI No. 9499).pdf Attached please find NRC staffs request for additional information (RAI) concerning review of the NuScale Design Certification Application.

Please submit your technically correct and complete response within 60 days of the date of this RAI to the NRC Document Control Desk.

If you have any questions, please contact me.

Thank you.

Prosanta Chowdhury, Project Manager Licensing Branch 1 (NuScale)

Division of New Reactor Licensing Office of New Reactors U.S. Nuclear Regulatory Commission 301-415-1647

Hearing Identifier:

NuScale_SMR_DC_RAI_Public Email Number:

485 Mail Envelope Properties (BN7PR09MB2609F8895F28710CEC50E9949E810)

Subject:

Request for Additional Information No. 454 eRAI No. 9499 (15)

Sent Date:

5/1/2018 4:24:04 PM Received Date:

5/1/2018 4:24:07 PM From:

Chowdhury, Prosanta Created By:

Prosanta.Chowdhury@nrc.gov Recipients:

"Lee, Samuel" <Samuel.Lee@nrc.gov>

Tracking Status: None "Cranston, Gregory" <Gregory.Cranston@nrc.gov>

Tracking Status: None "Franovich, Rani" <Rani.Franovich@nrc.gov>

Tracking Status: None "Karas, Rebecca" <Rebecca.Karas@nrc.gov>

Tracking Status: None "Schmidt, Jeffrey" <Jeffrey.Schmidt2@nrc.gov>

Tracking Status: None "NuScaleDCRaisPEm Resource" <NuScaleDCRaisPEm.Resource@nrc.gov>

Tracking Status: None "Request for Additional Information" <RAI@nuscalepower.com>

Tracking Status: None Post Office:

BN7PR09MB2609.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 556 5/1/2018 4:24:07 PM Request for Additional Information No. 454 (eRAI No. 9499).pdf 11743 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

Request for Additional Information No. 454 (eRAI No. 9499)

Issue Date: 05/01/2018 Application

Title:

NuScale Standard Design Certification 048 Operating Company: NuScale Power, LLC Docket No.52-048 Review Section: 15 - Introduction - Transient and Accident Analyses Application Section:

QUESTIONS 15-11 10 CFR Part 52.47(a)(3) requires an applicant for a design certification to provide the principal design criteria (PDC) for the facility and the design bases and the relation of the design bases to these principal design criteria. In addition, 10 CFR 52.47(a)(3) notes that Appendix A to 10 CFR part 50, general design criteria (GDC), provides guidance to applicants in establishing principal design criteria. In Final Safety Analysis Report (FSAR) Tier 2, Section 3.1, "Conformance with U.S. Nuclear Regulatory Commission General Design Criteria," the applicant describes how NuScale meets the intent of the GDCs or has developed PDC to address the specific design of the NuScale Power Plant pressurized water reactor.

The applicant has also provided a description of a small subset of the design criteria in Section 15.0.0.3, "Licensing Methodology," stating that these criteria were used in developing the conditions and assumptions for the Chapter 15 safety analysis. However, the staff notes that while some applicable GDCs are listed, a number of GDCs are not listed. Examples include GDCs 10, 15, 20, 25 and 28.

To enable the NRC staff to make a safety finding for FSAR Section 15, the staff is requesting the applicant to provide additional information regarding the intent of Section 15.0.0.3 or, if necessary, revise this section to clearly indicate the relationship between this section, Section 3.1, and the Chapter 15 analyses.