e REGULATORY DOCI\\ET FHF r,(JDY *... **
VIRGINIA ELECTRIC AND POWER COMPANY.*-
ij RICHMOND,VIBGINIA 23261 January 3,' 1979:
Mr. A. Schwencer, Chief Operating Reactors Branch 1 Division of Operating Reactors U.S. Nuclear Regulatory Commission.
Washington, D. C.
20555
Dear Mr. Schwencer:
Serial No.
690/112878*
PO/DAC:scj Docket No.: 50-280 50-281 License No.: DPR-32
. DPR-37
Subject:
Containment Purging During Normal Plant Operation Surry Power Station Unit Nos. 1 and 2
.. This is. in response to your letter of November 28,
- 1978 regaz:ding.
containment purging during 'operation.
Since both Surry units operate with sub-atmospheric containments as.
specified *in' the' Technical Specifications, containment purging* operations are not all.owed during power operat_ion, hot standby' or hot shutdown conditions.
The Technical Specifications require that containment integrity be established prior to increasing reactor coolant temperature above 200F and that containment *air partial pressure be within specification before exceeding 350F. Operation of the purge inlet and-outlet valves above 350F would result in a violation of the Technical Specification concerning containment internal pressure.
Current Technical Specifications require that containment vacuum be maintained for all plant conditions for which engineered safeguards systems are required operational. Physical limitations prohibit containment purging unless containment vacu~m is broken.
Furthermore, purge valves receive an automatic signal to close on a high radiation signal and there is no install-ed override capability for this function.
For these reasons, we do not feel that an amendment to Technical Specifications is required. in regard to
- -:;~
purging operations.
In addition, a review of safety injection override circuitry at Surry was conducted. On the basis of this study, it is our position that sufficient physical features, administrative controls, and procedures are provided at Surry to prevent an unsafe override of equipment important to safety.
t<l901()8 Cl ~ \\
cc:. Mr. James P. O'Reilly Very truly yours,
.* -/**. ) ) ;*.. ;.._, *,
c/\\.,:1/..,... ' '~.df::i'ttc ~ C.;-*;2~--.
. C. M. Stallings Vice President-Power Supply and Production Operations p