ML18113A693

From kanterella
Jump to navigation Jump to search
Forwards Proposed Amend to Oper Lic DPR-32.Proposed Change Is to Extend Oper for Addl Nine Months from Completion of Upcoming Steam Generator Inspec.W/Check for $4,000.00
ML18113A693
Person / Time
Site: Surry 
Issue date: 12/12/1978
From: Stallings C
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton, Schwencer A
Office of Nuclear Reactor Regulation
References
NUDOCS 7812150282
Download: ML18113A693 (5)


Text

. --~

~.* :... >'

~ *~:.,

~~ :* ;. :

VIBGINIA ELECTBIC AND PowEH COMPANY RICHMOND, VIRGINIA 23209 December 12~ 1978

. ~r. Harold. R. Denton, Di rector

  • * *. Off*ice of Nuclear Reactor Regulation Attn: Mr. Albert Schwencer, Chief Operating Reactors Branch 1 Divisio*n of Reactor Licensing
U* :S..
  • Nuclear Regulatory Commissio*n Washi_ngton, DC
  • 20555

Dear Mro Denton:

Seriai No. 703 **.

  • . LQA/JEE:jab Docket No.

50e280

  • License No.* *oPR-32.

SURRY POWER STATION UNIT ONE

  • PROPOSED* AMENDMENT TO: OPERATING' liCENSE.

. Pursuant to 10 CFR 50. 90, the Vi rgi ni a Electric and Power Com-pany hereby requests an amendment to Opera.ting Li c:ense

Surry Power Station Unit ijo. J.

The proposed change is to extend operation for an additional nine months from the completion of the upcoming steam generator inspec-tion with the same conditions and limitations as issued in the June 23,".

1978 Order for Modification of Licen~e.

The Unit No. l steam generator inspection program began on December 11, 1978 and will extend to approximately Jan*uary 2,' 1979...

Following this outage Unit Nao l will operate until approximately

. Novembe*r 1, 1979 at which.time the unit will be shutdown for*refueli_ng

. and replace~ent of stea'I'! generators

  • Details of the inspection program are included in the* att~chment..

The inspection program is based on a d*etermination of those regions of the tube sheet where *s_i gni fi cant deformation of tubes JJ!ig_~t have *occurred.

This determination is based on experience gained in previous inspections and on the growth of the 17.5% strain bou*ndary as developed by finite element an*alysis.

The basic plugging criteria will be the same as used in the previous inspectiqn. 'Additionally,' since subsequent operation will be for a period of nine months, additional pl_uggi_ng will be done based on inspection results..

The Station and System Nuclear Safety and Operating Conmittees have concluded that operation of Unit 1 for an additional nine months of.

equivalent full power operation under current NRC conditions would not be*

inimical to the health and safety of the public.

~- '. ~ *'

.. VIROINIA ELECTRIC AND POWER COMPAl',"Y TO Mr. Harold R. Denton 2

This request has been evaluated in accordance with the criteria*

specified in 10 CFR 170a~2. The requested amendment is a clearly defined

  • issue that has acceptability identified by NRC positions as seen in recent *.
  • Orders involvi_ng stea(J! generator inspections. Consequently, the request is therefore considered to be a Class III, and a check, no. 1056~ in the amount of $4000.00 is attach~d.

cc:* Mr. James:P. O'Reilly, Director Attachments Very truly yours,

?l.m~

C. :Me Stall 1 ngs Vice Presi dent-Po*wer Supply and Production Operations

'I

COMMONWEALTH OF VIRGINIA CITY OF RICHMOND

)

) s. s.

)

Befqre me, a Notary Public~ in and for the City and Common-*

w~aith aforesaid, today personally appeared C. M. Stallings, who being duly sworn, made oath and said (1) that he is Vice President-Power Supply and Production Operations, of the Virginia Electric and Power Company, (2)' that he is duly authorized to execute and file the fore-going Amendment in behalf of that Company, and (3) that the statements in the Amendment are true to the best of his knowledge and belief.,

Given under my hand and nota r i a 1 sea 1 this /2th day of Deceda bee

, ~-

My Commission expires __.,)-o-Y2

....... M~4-v_y,._._2_.._t!'~,..--1_9.__&,_J~-o

~*J?Z:~*

~

Notary-Public I

  • (SEAL)
1.

I

\\

~-*

SURRY UNIT No. 1 STEAM GENERATOR INSPECTION PROGRAM

1.
a.

Unplugged tubes in all steam generators rows, 2-5 columns 1-92 tested at 100 KHZ. using beaded flex probe.

b.

Any tubes which give indications at 100 KHZ should be re-examined at 400 KHZ.

2.* Tube gauging should be conducted in the hot legs of all steam generators utilizing three different eddy current probe sizes (0.540", 0.610", and 0.650 diameters).

Extenl of. gauging is indicated in figure 1 Cs.olid line).

NOTE:

During gauging, 400 KHZ low gain is recommended.

3.

Tube gauging should be conducted in the cold legs of all steam generators utilizing probe sizes 0.610" and 0.540 11

  • Extent of gaguing is as indicated on 'Figure 1 (dotted line).
4.

Wrapper to shell annulus measurements should be performed in steam generator C.

S.

Handhole inspections using TV and/or photographs should be.performed to inspect flow slots.

6.

Preventive plugging based upon inspection results.

\\

~

(,.

1-SER'IES 51

\\*

-(

i-I

?3 9189 87 &35 83 FJI 79 77 15 73 71 Ii} ~7,s "3,1 59 51 55 ~3 5/ 49 414543 4/ 39 37 35 33 3/ 29 27 25 23 21 IY /1 15 13 II 9 1 5 3 /

COLUMNS 94 9Z 90 8~ 8(.. M 82 80 78 1~ 14 72 70 C..S '-'1 t,,4 ~~ ton 5B '5/'1 54 52 50 4! 4t. 44 42 4,, 38 3b 34 32 30 28 2k. 24 2l 20 18 Iii, II/ /2 10 8 /.i, a Z I

i,,

l

~

4 I 3 9

,; 7

3 3 I z 9 I

j, i:

. '**-**