Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge. New Jersey 08038-0236 Nuclear Business Unit OCT 3 0 1996 LR-N96343 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

LER 272/96-026-00 SALEM GENERATING STATION -

UNIT 1 FACILITY OPERATING LICENSE NO. DPR-70 DOCKET NO. 50-272 This Licensee Event Report entitled "Inadequate Testing of Residual Heat Removal Hot Leg Flow Path," is being submitted pursuant to the requirements of the Code of Federal Regulations 1 0 C FR 5 0. 7 3 ( a ) ( 2 ) ( i ) ( B ).

Attachment SORC Mtg.96-152 BJT/

C Distribution LER File 3.7 9611130288 961030 PDR ADOCK 05000272 S

PDR Sincerely, rQJ! r: J-i?J~

David F.

1

~~:chow General Manager -

Salem Operations I I 95-2168 REV. 5,94

Document Control Desk LR-N96343 Attachment A The following item represents commitments that Public Service Electric & Gas (PSE&G) made to the Nuclear Regulatory Commission (NRC) relative to this LER (272/96-026-00).

The commitments are as follows:

1. As stated in LER 272/95-018-00, procedure revisions to ensure adequate IST program maintenance and implementation are in progress and will be completed prior to restart of each Salem Unit.

This includes Operations procedures implementing Technical Specification 4.0.5.