ML18102A369
| ML18102A369 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 06/30/1996 |
| From: | Garchow D, Leopardi J Public Service Enterprise Group |
| To: | |
| Shared Package | |
| ML18102A368 | List: |
| References | |
| NUDOCS 9609120224 | |
| Download: ML18102A369 (3) | |
Text
--- -**--1.. -...... ~
NAME PSE&G ADDREss=p.0. BOX 236/N21
= =
=
=
=
HANCOCK~RIDGE_,NJ~038 ___ _
FACILITY PSE&G SALEM GENERATING STATION Ol'U\\:I:LUl:"Uil:i rUJ:iLUXAlllll D..a."5Cl'DUCGl!i..,.L1J.T.1..1...&!tA.1.J:Oli SiS1&"1 \\Nl'DES)
DISCllARGE MONITORING REPORT (DMR)
(2-16)
(17-19)
I NJ0005622 I
I 489C I
PERMIT NUMBER I
IDISCUARGE NUMBER MONITORING PERIOD MAJOR LOCATIO~ LOWER ~LLOWAY_e__ CREEK...!...._ NJ _Q_8 0 3 ~
FROM YEAR I MO I DAY I I YEAR I MO I DAY 9 6 I 0 6 I 0 1 I TO I 9 6 I 0 6 l 3 0 SOUTHERN REGION /
SALEM DMR NUMBER: NJ0005622 489C 061996 (20-21) (22-23) (24-25)
(26-27) (28-29) (30-31)
(3 Card Only)
QUANTITY OR LOADING (4 Card Only)
QUALITY OR CONCENTRATION PH PARAMETER (32-37) 00400 1
0 EFFLUENT GROSS SOLIDS, TOTAL SUSPENDED 00530 1
0 (46-53)
(54-61)
(38-45)
UNITS 7.3 NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF LAW TllAT I llAVE PERSONALLY EXAMINED AND AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN; AND BASED DAVID F. GARCHOW ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR OBTAINING THE INFORMATION, I BELIEVE THE SUBMITTED INFORMATION GEN. MGR. SALEM OPERATION s TRUE, ACCURATE AND COMPLETE. I AM AWARE TllAT THERE ARE SIG-NIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION, INCLUDING THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 USC § 1001 AND f----------------j3J USC § 1319. (Penalties under these statutes may include fines up to TYPED OR PRINTED
$10,000 and/or maximum imprisonment of between 6 months and 5 years.)
(46-53)
(54-61)
J NO.
SAMPLE TYPE UNITS 7.3 09 935-6000 96 08 21 AREA CODE NUMBER YEAR MO DAY TOTAL SUSPENDED SOLIDS SHALL NOT EXCEED A 7-DAY AVERAGE OF 45 MG/L.
DSN 489 IN PERMIT THIS DISCHARGE IS DESIGNATED AS EPA Form 3320-1 (Rev. 9-88) Previous editions may be u~ed.
9609120224 960821 PDR ADOC~ 05000272 R
PDR LABS: 17327 08153 82888 PAGE 1
OF 1
Form T-VWX-Q14 2/92
- NEW JERSEY-T. OF ~NVIRO~MENTAL PROTECTION.ENERGY MONITORING REPORT - TRANSMITTAL SHEET NJPDES NO.
REPORTING PERIOD MO.
YR.
MO. YR.
THRU PERMITTEE:
Name Public Service Electric and Gas Company Address P.O. Box 236 Hancock's Bridge, NJ 08038 FACILITY:
Name Salem Nuclear Generating Station Address Alloway Creek Neck Road Hancock's Bridge Telephone (609) 935-6000 FORMS ATTACHED (Indicate Quantity of Each)
SLUDGE REPORTS - Sanitary DT-VWX-007 D T-VWX-008 DT-VWX-009 SLUDGE REPORTS - Industrial 0T-VWX-010A DT-VWX-0108 WASTEWATER REPORTS D T-VWX-011 D
T-VWX-012 D T-VWX-013 GROUNDWATER REPORTS D VWX-015(A,B)
D VMX-016
- [] VMX-017 (County) Salem OPERATING EXCEPTIONS DYE TESTING TEMPORARY BYPASSING DISINFECTION INTERRUPTION MONITORING MALFUNCTIONS UNITS OUT OF OPERATION OTHER (Detail any "Yes" on reverse side in appropriate space.)
YES NO D ~
D ~
D ~
~ D D ~
D ~
NPDES DISCHARGE MONITORING REPORT
[I:) EPA FORM 3320-1 NOTE: The "Hours Attended at Plant" on the reverse of this sheet must also be completed.
AUTHENTICATION-I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment.
LICENSED OPERATOR Name (Printed) JOHN F. LEOPARDI G.rade & ~2 0013703 S*gna~----==----=-----
Date 08/21 /96 PRINCIPAL EXECUTIVE OFFICER or DULY AUTHORIZED REPRESENTATIVE Name (Printed) DAVID F. GARCHOW Title (Printe Date 08/21 /96
~
~~
OPERA1'1NG EXCEPTIONS DETAILED Page 2 Reports for Facility 489C, the Oily Water Seperator, are being corrected due to a flow totalization mismatch between the local totalizer and the Scada computer.
HOURS ATTENDED AT PLANT Mo nth l_Q_L§_j Year~
Day of Month 1
2 3
4 5
6 7
8 9 10 11 12 13 14 15 16 Licensed Operator 0
0 8
8 8
8 8
0 0
8 8
8 8
8 0
0 Others 0
0 4
4 4
4 4
0 0
4 4
4 4
4 0
0 Day of Month 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Licensed Operator 8
8 8
8 8
0 0
8 8
8 8
8 0
0 Others 4
4 4
4 4
0 0
4 4
4 4
4 0
0