ML18101A798

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-272/95-06 & 50-311/95-06 on 950313-17 & 0327-31.No Violations Noted
ML18101A798
Person / Time
Site: Salem  PSEG icon.png
Issue date: 06/21/1995
From: Modes M
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Eliason L
Public Service Enterprise Group
Shared Package
ML18101A800 List:
References
NUDOCS 9506280644
Download: ML18101A798 (1)


See also: IR 05000272/1995006

Text

June 21, 1995

Mr. Leon R. Eliason

Chief Nuclear Officer & President

Nuclear Business Unit

Public Service Electric and Gas Company

P. 0. Box 236

Hancocks Bridge, New Jersey 08038

SUBJECT:

COMBINED INSPECTION REPORT NOS. 50-272/95-06 AND 50-311/95-06

Dear Mr. Eliason:

This letter refers to an inspection conducted by Mr. S. K. Chaudhary of this

office during the periods of March 13-17 and March 27-31, 1995, at the

Salem. Nuclear Generating Station, Units 1 and 2, Hancocks Bridge, New Jersey.

Mr. Chaudhary discussed the findings of this inspection by telephone with your

staff on April 11, 1995.

The telephone exit was organized by Mr. R. Villar of

your staff.

The inspection was intended to promote public health and safety and focused on

the piping and pipe support modification and design changes in both units.

Within these areas, the inspection consisted of selective examination of

procedures and representative records, interviews with personnel, and

observation by the inspector.

Within the scope of this inspection, we noted that the configuration baseline

documentation program is satisfactory; however, a PSE&G internal evaluation of

safety concerns raised by a former employee was still in progress, thus this *

item remains open for further review by the NRC.

No reply to this letter is necessary, and your cooperation with us is

appreciated.

Docket Nos. 50-272; 50-311

Sincerely,

Michael C. Modes, Chief

Materials Section

Division of Reactor Safety

Enclosure:

Combined Inspection Report Nos.

50-272/95-06 and 50-311/95-06

9506280644 950621

PDR

ADOCK 05000272

G

PDR