Notifies of Change to Salem Unit 2 ERDS Data Point Library. Changes Affect Conversion Parameters for Four Feedwater Flow Points Defined in Unique Sys Description Field Entry on Data Point Library Form
ML18101A525
Person / Time
Site: Salem 
Issue date: 01/24/1995
From: Hagan J
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
LR-N94290, NUDOCS 9502070168
Download: ML18101A525 (18)


Text

Public Service Electric and Gas Company Joseph J. Hagan Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-1200 Vice President - Nuclear Operations JAN 2 4 1995 LR-N94290 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

EMERGENCY RESPONSE DATA SYSTEM DATA POINT LIBRARY CHANGE SALEM GENERATING STATION UNIT NO. 2 FACILITY OPERATING LICENSE NO. DPR-75 DOCKET NO. 50-311 In accordance with 10CFR50 Appendix E, Section VI.3.a, Public Service Electric & Gas hereby notifies the NRC of a change to the Salem Unit No. 2 Emergency Response Data System Data Point Library (DPL).

Specifically, the changes affect the conversion parameters for four feedwater flow points defined in the "Unique System Description" field entry on the DPL form (Attachment 1).

This change was implemented on December 30, 1994, during Refueling Outage 8 as ?art of a plant modification to feedwater flow nozzles. contains the revised DPL forms which incorporate the changes. contains a copy of Table 4 "Calorimetric Values for Feedwater and Saturated steam," of Salem Unit No.2 Procedure S2.RE-RA.ZZ-0011(Q) which is referenced by the "Unique System Description" field entry.

Should you have any questions regarding this request, we will be pleased to discuss them with you.

Attachments (2) 9502070168 950124 PDR ADOCK 05000311 F

PDR Sincerely,

Document Control Desk LR-N94290 c Mr. T. T. Martin, Administrator - Region I

u. s. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. L. N. Olshan, Licensing Project Manager -

Salem

u. s. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, MD 20352 Mr. c. Marschall (S09)

USNRC Senior Resident Inspector Mr. K. Tosch, Manager IV NJ Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 95-4933

ATTACHMENT 1 EMERGENCY RESPONSE DATA 8-YSTEM DATA POINT LIBRARY CHANGE SALEM UNIT.NO. 2 FACILITY OPERATING LICENSE NO. DPR-75 DOCKET NO. 50-311 LR-N94290

DATA POINT LIBRARY REFERENCE FILE Date:

12/21/94 Reactor Unit:

SA2 Data Feeder:

SPDS NRC ERDS Parameter:

MN FD FL 1 Point ID:

U2FT0510S Plant Spec Point Desc.:

  1. 21 SG FEEDWATER IN FLO CHAN I Generic/Cond Desc.:

STEAM GENERATOR FEED FLOW Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

SQRT OF DP

  • CONST Minimum Instr Range:

12 Maximum Instr Range:

120 Zero Point

Reference:

NA Reference Point Notes:

NA PROC or SENS:

s Number of Sensors:

001 How Processed:

NA Sensor Locations:

BETWEEN FW HEATER & SG Alarm/Trip Set Points:

NONE NI Detector Power Supply Cut-off Power Level:

NA NI Detector Power Supply Turn-on Power Level:

NA Instrument Failure Mode:

LOW Temperature Compensation For DP Transmitters:

Y Level Reference Leg:

NA Record No. 15 Page 1 of 2

DATA POINT LIBRARY REFERENCE FILE CONT.

NRC EROS Parameter:

Point ID:

Plant Spec Point Desc.:

Unique System Desc.:

MN FD FL 1 U2FT0510S

  1. 21 SG FEEDWATER IN FLO CHAN I FLOW < 12% NOT MEANINGFUL; VALUES CLAMPED.

CONVERT % TO LBM/HR:

FLOW LBM/HR = 14498 X THERMAL EXPANSION FACTOR X SQRT(SPECIFIC WT) X FLOW IN PERCENT I 2.85321 FOR EXPANSION FACTOR AND SQRT SPECIFIC WEIGHT, REFER TO TABLE 4 OF PROCEDURE S2.RE-RA.ZZ-001l(Q).

Record No. 15 Page 2 of 2

DATA POINT LIBRARY REFERENCE FILE Date:

12/21/94 Reactor Unit:

SA2 Data Feeder:

SPDS NRC EROS Parameter:

MN FD FL 2 Point ID:

U2FT0520S Plant Spec Point Desc.:

  1. 22 SG FEEDWATER IN FLO CHAN I Generic/Cond Desc.:

STEAM GENERATOR FEED FLOW Analog/Digital:

A Engr Units/Dig states:

Engr Units Conversion:

SQRT OF DP

  • CONST Minimum Instr Range:

12 Maximum Instr Range:

120 Zero Point

Reference:

NA Reference Point Notes:

NA PROC or SENS:

S Number of Sensors:

001 How Processed:

NA Sensor Locations:

BETWEEN FW HEATER & SG Alarm/Trip Set Points:

NONE NI Detector Power supply cut-off Power Level:

NA NI Detector Power Supply Turn-on Power Level:

NA Instrument Failure Mode:

LOW Temperature Compensation For DP Transmitters:

Y Level Reference Leg:

NA Record No. 16 Page 1 of 2

DATA POINT LIBRARY REFERENCE FILE CONT.

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Unique system Desc.:

MN FD FL 2 U2FT0520S

  1. 22 SG FEEDWATER IN FLO CHAN I FLOW < 12% NOT MEANINGFUL; VALUES CL.~ED.

CONVERT % TO LBM/HR:

FLOW LBM/HR = 14503 X THERMAL EXPANSION FACTOR X SQRT(SPECIFIC WT) X FLOW IN PERCENT I 2.s5409 FOR EXPANSION FACTOR AND SQRT SPECIFIC WEIGHT, REFER TO TABLE 4 OF PROCEDURE S2.RE-RA.ZZ-00ll(Q).

Record No. 16 Page 2 of 2

DATA POINT LIBRARY REFERENCE FILE Date:

12/21/94 Reactor Unit:

SA2 Data Feeder:

SPDS NRC ERDS Parameter:

MN FD FL 3 Point ID:

U2FT0530S Plant Spec Point Desc.~

  1. 23 SG FEEDWATER IN FLO CHAN I Generic/Cond Desc.:

STEAM GENERATOR FEED FLOW Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

SQRT OF DP

  • CONST Minimum Instr Range:

12 Maximum Instr Range:

120 Zero Point

Reference:

NA Reference Point Notes:

NA PROC or SENS:

S Number of Sensors:

001 How Processed:

NA Sensor Locations:

BETWEEN FW HEATER & SG Alarm/Trip Set Points:

NONE NI Detector Power Supply cut-off Power Level:

NA NI Detector Power Supply Turn-on Power Level:

NA Instrument Failure Mode:

LOW Temperature Compensation For DP Transmitters:

Y Level Reference Leg:

NA Record No. 17 Page 1 of 2

DATA POINT LIBRARY REFERENCE FILE CONT.

NRC EROS Parameter:

Point ID:

Plant Spec Point Desc.:

Unique System Desc.:

MN FD FL 3 U2FT0530S

  1. 23 SG FEEDWATER IN FLO CHAN I FLOW < 12% NOT MEANINGFUL; VALUES CLAMPED.

CONVERT % TO LBM/HR:

FLOW LBM/HR = 14498 X THERMAL EXPANSION FACTOR X SQRT(SPECIFIC WT) X FLOW IN PERCENT I 2.85338 FOR EXPANSION FACTOR AND SQRT SPECIFIC WEIGHT, REFER TO TABLE 4 OF PROCEDURE S2.RE-RA.ZZ-00ll(Q).

Record No. 17 Page 2 of 2

DATA POINT LIBRARY REFERENCE FILE Date:

12/21/94 Reactor Unit:

SA2 Data Feeder:

SPDS NRC EROS Parameter:

MN FD FL 4 Point ID:

U2FT0540S Plant Spec Point Desc.:

  1. 24 SG FEEDWATER IN FLO CH I Generic/Cond Desc.:

STEAM GENERATOR FEED FLOW Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

SQRT OF DP

  • CONST Minimum Instr Range:

12 Maximum Instr Range:

120 Zero Point

Reference:

NA Reference Point Notes:

NA PROC or SENS:

s Number of Sensors:

001 How Processed:

NA Sensor Locations:

BETWEEN FW HEATER & SG Alarm/Trip Set Points:

NONE NI Detector Power Supply Cut-off Power Level:

NA NI Detector Power Supply Turn-on Power Level:

NA Instrument Failure Mode:

LOW Temperature Compensation For DP Transmitters:

Y Level Reference Leg:

NA Record No. 18 Page 1 of 2

I DATA POINT LIBRARY REFERENCE FILE CONT.

NRC EROS Parameter:

Point ID:

Plant Spec Point Desc.:

Unique System Desc.:

MN FD FL 4 U2FT0540S

  1. 24 SG FEEDWATER IN FLO CH I FLOW < 12% NOT MEANINGFUL; VALUES CLAMPED.

CONVERT % TO LBM/HR:

FLOW LBM/HR = 14488 X THERMAL EXPANSION FACTOR X SQRT(SPECIFIC WT) X FLOW IN PERCENT I 2.05141 FOR EXPANSION FACTOR AND SQRT SPECIFIC WEIGHT, REFER TO TABLE 4 OF PROCEDURE S2.RE-RA.ZZ-00ll(Q).

Record No. 18 Page 2 of 2

ATTACHMENT 2 TABLE 4 OF PROCEDURE S2.RE-RA.ZZ-001l(Q)

SALEM UNIT NO. 2 FACILITY OPERATING LICENSE NO. DPR-75 DOCKET NO. 50-311 LR-N94290

FW Temp (°F}

32 33 34 35 36 37 38 39....

40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 Salem 2 TABLE4 Page 1 of6 s2.RE-RA.ZZ-001 l(Q)

CALORIMETRIC VALUES FOR FEEDWATER AND SATURATED STEAM Enthalpy Square Rt Exp an FW Enthalpy Square Rt Exp an (Btu/lbm)

Sp Wt Factor Temp (°F)

(Btu/lbm)

Sp Wt Factor 2.7 7.9131 73 43.53 7.9017 1.0001 3.7 7.9131 74 44.53 7.9013 1.0001 4.7 7.9131 75 45.52 7.9008 1.0001 5.7 7.9131 76 46.51 7.9003 1.0002 6.7 7.9131 77 47.51 7.8998 1.0002 7.69 7.9131 78 48.5 7.8993 1.0002 8.69 7.9131 79 49.5 7.8988 1.0002 9.69 7.9131 80 50.49 7.8983 1.0002 10.69 7.9131 81 51.48 7.8978 1.0003 11.69 7.9126 82 52.48 7.8973 1.0003 12.68 7.9126 83 53.47 7.8968 1.0003 13.68 7.9124 84 54.47 7.8963 1.0003 14.67 7.9121 85 55.46 7.8958 1.0003 15.67 7.9119 86 56.45 7.8953 1.0003 16.67 7.9116 87 57.45 7.8948 1.0004 17.66 7.9114 88 58.44 7.8944 1.0004 18.66 7.9111 89 59.44

. 7.8939 1.0004 19.65 7.9109 90 60.43 7.8934 1.0004 20.65 7.9106 91 61.42 7.8924 1.0004 21.65 7.9104 92 62.42 7.8914 1.0005 22.64 7.9101 93 63.41 7.8904 1.0005 23.64 7.9099 94 64.41 7.8894 1.0005 24.63 7.9096 95 65.4 7.8885 1.0005 25.63 7.9094 96 66.39 7.8875 1.0005-*

26.62 7.9092 97 67.39 7.8865 1.0006 27.62 7.9089 98 68.38 7.8855 1.0006 28.61 7.9087 99 69.38 7.8845 1.0006 29.61 7.9084 100 70.37 7.8836 1.0006 30.6 7.9082 101 71.36 7.882" 1.0006 31.6 7.9077 102 72.36 7.881 1.0007 32.59 7.9072 103 73.35 7.881 1.0007 33.59 7.9067 104 74.35 7.88 1.0007 34.58 7.9062 105 75.34 7.879 1.0007 35.58 7.9057 106 76.33 7.878 1.0007 36.57 7.9052 107 77.33 7.878 1.0008 37.57 7.9047 108 78.32 7.877 1.0008 38.56 7.9042 1.0000 109 79.32 7.876 1.0008 39.56 7.9037 1.0000 110 80.31 7.876 1.0008 40.55 7.9032 1.0000 111 81.31 7.875 1.0008 41.54 7.9027 1.0001 112 82.3 7.874 1.0009 42.54 7.9022 1.0001 113 83.3 7.873 1.0009 Page 6of11 Rev. 41

FW Enthalpy Square Rt Ex pan Temp (°F)

(Btu/Ihm)

Sp Wt Factor 114 84.29 7.872 1.0009 115 85.29 7.871 1.0009 116 86.28 7.87 1.0009 117 87.28 7.869 1.0009 118 88.27 7.868 1.0010 119 89.27 7.867 1.0010 120 90.26 7.866 1.0010 121 91.26 7.865 1.0010 122 92.25 7.865 1.0010 123 93.25 7.864 1.0011 124 94.24 7.863 1.0011 125 95.24 7.862 1.0011 126 96.24 7.861 1.0011 127 97.23 7.86 1.0011 128 98.23 7.859 1.0012.

129 99.22 7.858 1.0012 130 100.22 7.857 1.0012 131 101.22 7.856 1.0012 132 102.21 7.854 1.0012 133 103.21 7.853 1.0013 134 104.2 7.852 1.0013 135 105.2 7.851 1.0013 136 106.2 7.849 1.0013 137 107.19 7.848 1.0013 138 108.19 7.847 1.0014 139 109.18 7.846 1.0014 140 110.18 7.845 1.0014 141 111.18 7.843 1.0014 142 112.17 7.842 1.0014 143 113.17 7.841 1.0015 144 114.16 7.84 1.0015 145 115.16 7.839 1.0015 146 116.16 7.837 1.0015 147 117.15 7.836 1.0015 148 118.15 7.835 1.0015 149 119.14 7.834 1.0016 150 120.14 7.833 1.0016 151 121.14 7.831 1.0016 152 122.14 7.83 1.0016 153 123.13 7.829 1.0016 154 124.13 7.828 1.0017 155 125.13 7.827 1.0017 Salem2 TABLE4 p

2 f6 age 0

FW Temp (°F) 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 Enthalpy (Btu/lbm) 126.13 127.13 128.12 129.12 130.12 131.12 132.12 133.11 134.11 135.11 136.11 137.11 138.1 139.1 140.1 141.1 142.1 143.1 144.1 145.1 146.09 147.09 148.09 149.09 150.09 151.09 152.09 153.09 154.09 155.09 156.09 157.09 158.09 159.09 160.09 161.09 162.09 163.09 164.09 165.1 166.1 167.1 Page 7of11 s2.RE-RA. ZZ-0011 (Q)

Square Rt Exp an Sp Wt Factor 7.825 1.0017 7.824 1.0017 7.823 1.0017 7.822 1.0018 7.821 1.0018 7.819 1.0018 7.818 1.0018 7.817 1.0018 7.816 1.0019 7.815 1.0019 7.813 1.0019 7.812 1.0019 7.811 1.0019 7.81 1.0020 7.809 1.0020 7.807 1.0020 7.806 1.0020 7.804 1.0020 7.803 1.0021 7.802 1.0021 7.8 1.0021 7.799 1.0021 7.797 1.0021 7.796 1.0021 7.794 1.0022 7.793 1.0022 7.792 1.0022 7.79 1.0022 7.789 1.0022 7.787 1.0023 7.786 1.0023 7.785 1.0023 7.783 1.0023 7.782 1.0023 7.78 1.0024 7.779 1.0024 7.777 1.0024 7.775 1.0024 7.774 1.0024 7.772 1.0025 7.77 1.0025 7.769 1.0025 Rev. 41

FW Enthalpy Square Rt Exp an Temp {°F)

(Btu/lbm)

Sp Wt Factor 198 168.1 7.767 1.0025 199 169.1 7.765 1.0025 200 170.l 7.764 1.0026 201 171.1 7.762 1.0026 202 172.11 7.761 1.0026 203 173.11 7.76 1.0026 204 174.11 7.758 1.0026 205 175.12 1.151 1.0027 206 176.12 7.755 1.0027 207 177.12 7.754 1.0027 208 178.12 7.753 1.0027 209 179.13 7.751 1.0027 210 180.13 7.75 1.0027 211 181.13 7.748 1.0028 212 182.14 7.747 1.0028 213 183.14 7.745 1.0028 214 184.15 7.743 1.0028 215 185.15 7.742 1.0028 216 186.15 7.74 1.0029 217 187.16 7.738 1.0029 218 188.16 7.737 1.0029 219 189.17 7.735 1.0029 220 190.17 7.734 1.0029 221 191.18 7.732 1.0030 222 192.18 7.73 1.0030 223 193.19 7.728 1.0030 224 194.19 7.726 1.0030 225 195.2 7.724 1.0030 226 196.21 7.723 1.0031 227 197.21 7.721 1.0031 228 198.22 7.719 1.0031 229 199.22 7.717 1.0031 230 200.23 7.715 1.0031 231 201.24 7.714 1.0032 232 202.24 7.712 1.0032 233 203.25 7.71 1.0032 234 204.26 7.709 1.0032 235 205.27 7.707 1.0032 236 206.27 7.706 1.0033 237 207.28 7.704 1.0033 238 208.29 7.702 1.0033 239 209.29 7.701 1.0033 Salem 2 TABLE4 p

3 f6 age 0

FW Temp {°F) 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 Enthalpy (Btu/lbm) 210.3 211.31 212.32 213.33 214.34 215.35 216.36 217.37 218.38 219.39 220.4 221.41 222.42 223.44 224.45 225.46 226.47 227.48 228.5 229.51 230.52 231.53 232.55 233.56 234.58 235.59 236.6 237.62 238.63 239.65 240.66 241.68 242.69 243.71 244.73 245.75 246.76 247.78 248.8 249.81 250.83 251.85 Page 8of11 s2.RE-RA.ZZ-001l(Q)

Square Rt Ex pan Sp Wt Factor 7.699 1.0033 7.697 1.0033 1.695 1.0034 7.694 1.0034 7.692 1.0034 7.69 1.0034 7.688 1.0034 7.686 1.0035 7.685 1.0035 7.683 1.0035 7.681 1.0035 7.679 1.0035 7.677 1.0036 7.676 1.0036 7.674 1.0036 7.672 1.0036 7.67 1.0036 7.668 1.0037

. 7.666 1.0037 7.665 1.0037 7.60 1.0037 7.661 1.0037 7.659 1.0038 7.657 1.0038 7.655 1.0038 7.653 1.0038 7.651 1.0038 7.649 1.0039 7.647 1.0039 7.645 1.0039 7.643 1.0039 7.641 1.0039 7.639 1.0039 7.637 1.0040 7.636 1.0040 7.634 1.0040 7.632 1.0040 7.63 1.0040 7.628 1.0041 7.627 i.0041 7.625 1.0041 7.623 1.0041 Rev. 41

FW Enthalpy Square Rt Ex pan Temp (°F)

(Btu/lbm)

Sp Wt Factor 282 252.87 7.62 1.0041 283 253.89 7.618 1.0042 284 254.91 7.616 1.0042 285 255.93 7.614 1.0042 286 256.95 7.612 1.0042 287 257.97 7.609 1.0042 288 258.99

. 7.607 1.0043 289 260.01 7.605 1.0043 290 261.03 7.603 1.0043

- 291 262.05 7.601 1.0043 292 263.08 7.599 1.0043 293 264.1 7.597 1.0044 294 265.12 7.595 1.0044 295 266.15 7.593 1.0044 296 267.17 7.591 1.0044 297 268.19 7.589 1.0044 298 269.21 7.587 1.0045 299 270.24 7.585 1.0045 300 271.26 7.583 1.0045 301 272.29 7.581 1.0045 302 273.31 7.579 1.0045 303 274.34 7.577 1.0045 304 275.36 7.574 1.0046 305 276.39 7.572 1.0046 306 277.42 7.57 1.0046 307 278.44 7.568 1.0046 308 279.47 7.566 1.0046 309 280.49 7.564 1.0047 310 281.52 7.561 1.0047 311 282.55 7.559 1.0047 312 283.58 7.557 1.0047 313 284.61 1.555 1.0047 314 285.64 7.553 1.0048 315 286.67 7.551 1.0048 316 287.7 7.549 1.0048 317 288.73 7.546 1.0048 318 289.76 7.544 1.0048 319 290.79 7.542 1.0049 320 291.82 7.54 1.0049 321 292.85 7.538 1.0049 322 293.89 7.535 1.0049 323 294.92 7.533 1.0049 Salem 2 TABLE4 p

4 f6 aJ?:e 0

FW Temp (°F) 324.

325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 Enthalpy (Btu/lbm) 295.95 296.99 298.02 299.05 300.08 301.12 302.15 303.19 304.23 305.26 306.3 307.34 308.38 309.42 310.45 311.49 312.53 313.57 314.61 315.66 316.7 317.74 318.78 319.82 320.87 321.91 322.95 324 325.04 326.09 327.14 328.19 329.23 330.28 331.33 332.37 333.42 334.47 335.52 336.58 337.63 338.68 Page 9of11

. s2.RE-RA.ZZ-001l(Q)

Square Rt Ex pan Sp Wt Factor 7.531 1.0050 7.528 1.0050 7.526 1.0050 7.523 1.0050 7.521 1.0050 7.519 1.0051 7.516 1.0051 7.514 1.0051 7.512 1.0051 7.509 1.0051 7.507 1.0051 7.505 1.0052 7.502 1.0052 7;5 1.0052 7.498 1.0052 7.496 1.0052 7.493 1.0053 7.491 1.0053 7.489 1.0053 7.486 1.0053 7.484 1.0053 7.482 1.0054 7.479 1.0054 7.477 1.0054 7.475 1.0054 7.472 1.0054 7.47 1.0055 7.468 1.0055 7.465 -

1.0055 7.463 1.0055 7.46 1.0055 7.458 1.0056 7.455 1.0056 7.453 1.0056 7.45 1.0056 7.448 1.0056 7.445 1.0057 7.443 1.0057 7.44 1.0057 7.438 1.0057 7.435 1.0057 7.433 1.0057 Rev. 41

FW Enthalpy Square Rt Ex pan Temp {

0 F)

(Btu/lbm)

Sp Wt Factor 366 339.73 7.43 1.0058 367 340.78 7.428 1.0058 368 341.84 7.426 1.0058 369 342.89 7.423 1.0058 370 343.94 7.421 1.0058 371 345 7.418 1.0059 372 346.05 7.415 1.0059 373 347.11 7.413 1.0059 374 348.17 7.41 1.0059 375 349.23 7.407 1.0059 376 350.28 7.405 1.0060 377 351.34 7.402 1.0060 378 352.4 7.399 1.0060 379 353.45 7.397 1.0060 380 354.51 7.394 1.0060 381 355.57 7.392 1.0061 382 356.64 7.389 1.0061.

383 357.7 7.386 1.0061 384 358.77 7.384 1.0061 385 359.83 7.381 1.0061 386 360.89 7.379 1.0062 387 361.96 7.376 1.0062 388 363.02 7.373 1.0062 389 364.09 7.371 1.0062 390 365.15 7.368 1.0062 391 366.22 7.365 1.0063 392 367.29 7.363 1.0063 393 368.36 7.36 1.0063 394 369.43 7.357 1.0063 395 370.5 7.354 1.0063 396 371.56 7.351 1.0063 397 372.63 7.349 1.0064 398 373.7 7.346 1.0064 399 374.77 7.343 1.0064 400 375.84 7.34 1.0064 401 376.92 7.337 1.0064 402 377.99 7.334 1.0065 Salem2 TABLE4 p

5 f6 age 0

FW Temp {°F) 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 Enthalpy (Btu/lbm) 379.07 380.15 381.23 382.3 383.38 384.46 385.53 386.61 387.69 388.78 389.86 390.95 392.03 393.11 394.2 395.28 396.37 397.45 398.54 399.63 400.73 401.82 402.91 404 405.09 406.19 407.28 408.37 409.47 410.57 411.67 412.77 413.88 414.98 416.08 417.18 418.28 Page 10of11 s2.RE-RA.ZZ-001 l(Q)

Square Rt Ex pan Sp Wt Factor 7.331 1.0065 7.328 1.0065 7.325 i.0065 7.323 1.0065 7.32 1.0066 7.317 1.0066 7.314 1.0066 7.311 1.op66 7.308 1.0066 7.305 1.0067 7.302 1.0067 7.299 1.0067 7.296 1.0067 7.293 1.0067 7.29 1.0068 7.287 1.0068 7.285 1.0068 7.282 1.0068

. 7.279 1.0068 7.275 1.0069 7.272 1.0069 7.269 1.0069 7.266 1.0069 7.263 1.0069 7.26 1.0070 7.257 1.0070 7.254 1.0070 7.251 1.0070 7.248 1.0070 7.245 1.0070 7.242 1.0071 7.239 1.0071 7.236 1.0071 7.233 1.0071 7.23 1.0071 7.227 1.0072 7.224 1.0072 Rev. 41

SIG Pressure 750 760 770 780 790 800 810 820 830 840 850 860 870 880 890 900 910 920 930 940 950 960 970 980 990 1000 1010 Salem 2 Enthalpy (Btu/lbm) 1200.7 1200.4 1200.2 1199.9 1199.7 1199.4 1199.1 1198.8 1198.5 1198.2 1198.0 1197.7 1197.3 1197.0 1196.7 1196.4 1196.1 1195.7 1195.4 1195.1 1194.7 1194.4 1194.0 1193.7 1193.3 1192.9 1192.6 TABLE4 Page 6 of6 Page 11of11 s2.RE-RA.ZZ-0011 (Q)

Rev. 41