ML18101A469

From kanterella
Jump to navigation Jump to search
Comments on Licensee 941118 Application for Amends to Licenses DPR-70 & DPR-75,revising Reactivity Control Sys TS for Boration Flow Paths & Cps,By Reducing Min Number of Operable CPs Required for Boron Addition in Mode 4
ML18101A469
Person / Time
Site: Salem  
Issue date: 01/12/1995
From: Tosch K
NEW JERSEY, STATE OF
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
LCR-93-19, NUDOCS 9501240145
Download: ML18101A469 (2)


Text

1.

C.*

~

t,"

~*

State of New Jersey Department of Environmental Protection Robert C. Shinn, Jr.

Commissioner Division of Environmental Safety, Health, and Analytical Programs Radiation Protection Programs Bureau of Nuclear Engineering CN 415 Trenton, New Jersey 08625-0415 Tel (609) 987-2032

  • Fax (609) 987-6354 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555 Ladies & Gentlemen:

January 12, 1995

Subject:

Salem Units 1 & 2 -- Reactivity Control System Technical Specifications Limiting Conditions of Operation (LCO)

Request for License Amendment to Facility Operating License Nos DPR-70 & DPR-75 -- LCR 93-19 By letter to the U.S. Nuclear Regulatory Commission (NRC),

dated November 18, 1994, Public Service Electric and Gas Company (PSE&G) proposes to revise said Technical Specifications for boration flow paths and charging pumps, by reducing the minimum number of operable charging pumps required for boron addition in Mode 4 (hot shutdown) from two to one as permitted in the cases of Mode 5

(Cold Shutdown)

& Mode 6

(Refueling).

The stated justification for the PSE&G change request is to make the technical specifications consistent with (a) the current specifications for the Emergency Core Cooling System (ECCS), (b) with the limitations

_of the Cold Overpressure Protection analysis, and (c) consistent with the LCO of Salem Unit 2.

The boron injection system ensures that negative reactivity control is available during each mode of facility operation.

Per current licensing basis, at Reactor Cooling System (RCS) average temperature ~ 200°F a minimum of two injection flow paths are required to ensure single functional capability in the event an assumed failure renders one of the flow paths inoperable.

During Mode 4, the RCS average temperature is between 200° and 350° F. For RCS average temperature ~ 200°F, { Mode 5 (Cold Shutdown) & Mode 6 (Refueling)} a minimum of one of the boron injection flow path options is required to be operable.

The 350° F RCS average temperature corresponds to an operation status where the reactor reverts from critical to subcritical.

The proposed changes will impose additional conditions, provide clarifications, and bring consistency to the technical specifications documents of both Salem units.

950124oi45-95oi 12---1 PDR ADOCK 05000272 J

P PDR New jersey Js an Equal Opportunity Employer Recycled Paper

The New Jersey Bureau of Nuclear accordance with the following comment:

2 -

Department of Environmental Protection's and Engineering has reviewed the request in requirements of 10 CFR 50.9l(b) and has the Page 4.

2nd paragraph of Attachment 1

of the Proposed Technical Specification Change Request.

In the middle of the page, reference to "Table 3.1-2" probably meant to be to Figure 3.1-2, as no Table 3.1-2 could be located in the current Salem Unit 1 Technical Specifications document.

If you have any questions,

- please contact Ariadni Kapsalopoulou at (609) 987-2052 or Suren Singh at (609) 987-2039.

sincerely, Kent Tosch, Manager Bureau of Nuclear Engineering

c.

J. Lipoti, Ph.D., Assistant Director Radiation Protection Programs, NJDEP D. Chawaga, State Liaison Officer - Region I U.S. NRC L. Olshan, Licensing Project Manager, NRR U.S. NRC

c. Marschall, Artificial Island Senior Resident Inspector U.S. NRC F. Thomson, Manager Licensing and Regulation, PSE&G D. Zannoni, Supervisor NES, Bureau of Nuclear Engineering Radiation Protection Programs, NJDEP