ML18100B032

From kanterella
Jump to navigation Jump to search
Forwards ISI Activities 90 Day Rept for 11th Refueling Outage Salem Generating Station Unit 1,consisting of Form NIS-1, Owners Data Rept for ISI, Outage ISI Exam Results & Forms NIS-2 &/Or NR-1, ...Rept for Repairs Or..
ML18100B032
Person / Time
Site: Salem 
Issue date: 04/20/1994
From: Hagan J
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18100B033 List:
References
NLR-N94-68, NUDOCS 9404260395
Download: ML18100B032 (3)


Text

Public Service Electric and Gas Company Joseph J. Hagan Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-1200 Vice President - Nuclear Operations APR 2 0 1994 NLR-N94068 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

INSERVICE INSPECTION ACTIVITIES -

90 DAY REPORT ELEVENTH REFUELING OUTAGE SALEM GENERATING STATION UNIT NO. 1 DOCKET NO. 50-272 Public Service Electric & Gas Company (PSE&G) hereby provides in the enclosure to this letter, the Ninety (90) Day Report for Inservice Inspection (ISI) activities conducted at Salem Generating Station Unit No. 1 during the eleventh refueling outage.

This report is submitted in accordance with Section 4.0.5 of Appendix A to the Technical Specifications for Salem Generating Station Unit No. 1 and Article IWA-6230 of Section XI of the ASME Boiler and Pressure Vessel Code 1983 Edition through Summer of 1983 Addenda. of this submittal consists of Form NIS-1,"0wners Data Report for Inservice Inspection",* "Outage ISI Examination Results" for the second interval, second period, second outage and Forms NIS-2 and/or NR....;1 "Owner's Report for Repairs or Replacements".

Should there be any questions with regard to this submittal, please do not hesitate to contact us.

/~--9-4_0_4_2_0_0_3_9-=5c-.=9-=4--=o-=4-=2-=-o-,*. --\\

PDR ADOCK ** O~Q00272*

G

  • **PDR.

Sincerely, I

Document Control Desk NLR-N94068 C

Mr. J. C. Stone Licensing Project Manager Mr. c. Marschall Senior Resident Inspector 2

Mr. T. Martin, Administrator Region I Mr. Kent Tosch, Manager IV APR 2 0 1994 New Jersey Department of Environmental Protection pivision of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 Assistant Director New Jersey Department of Labor and Industry Office of Boiler and Pressure Vessel Compliance PO Box 1503, Labor and Industry Building CN 932 Trenton, NJ 08625

Document Control Desk NLR-N94068 ENCLOSURE 1