Public Service Electric and Gas Company Stanley LaBruna Public Service Electric and Gas' Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-1700 Vice President - Nuclear Engineering JUL 2 9 1993 NLR-N93122 U.S. Nuclear Regulatory Commission Attention:

Document Control Desk Washington, DC 20555 Gentlemen:

RESPONSE TO GENERIC LETTER 93-04 ROD CONTROL SYSTEM FAILURE AND WITHDRAWAL OF ROD CONTROL CLUSTER ASSEMBLIES SALEM GENERATING STATION UNITS 1 AND 2 DOCKET NOS~ 50-272 AND 50-311 This letter is to provide Public Service Electric and Gas's (PSE&G) response to the subject generic letter concerning the Rod Control System failure and withdrawal of a rod control cluster assembly which occurred at our Salem Unit 2 facility.

This response is submitted in accordance with the requirements of 10CFR50.54(f).

As a result of the failure detailed in the subject generic letter, PSE&G submitted a request for Emergency License Amendment on June 17, 1993, (Ref. LCR 93-21, PSE&G letter number NLR-N93098).

Attach~ent 1 of this amendment request included the information that the generic letter requests for submittal within 45 days; that is, assessment of the single failure on the rod control system, impact on the current licensing basis, and compensatory short-term actions to address the degraded or nonconforming conditions.

PSE&G will provide a plan and schedule for the long-term resolution of this issue by September 20, 1993 as required by the generic letter.

If you have any questions on this response, please do not hesitate to call.

Sincerely,

/&

100065

-~. *-:. ~..

cDocument Control Desk 2 -

NLR-N93122 Affidavit C

Mr. T. T. Martin, Administrator - Region I

u. s. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. J. c. Stone, Licensing Project Manager
u. s. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, MD 20852 Mr. T. P. Johnson (S09)

USNRC Senior Resident Inspector Mr. K. Tosch, Manager, IV NJ Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 JUL 2 9 1993

REF: NLR-N93122 STATE OF NEW JERSEY SS.

COUNTY OF SALEM

s. LaBruna, being duly sworn according to law deposes and says:

I am Vice President - Nuclear Engineering of Public Service Electric and Gas Company, and as such, I find the matters set forth in the above referenced letter, concerning the Salem Unit Nos. 1 and 2 are true to the best of my knowledge, information and belief.

Subscribed and Sworn to before me this c:f<f ls/.,_

dayof :er 4, 1993

~l;tt~e~

My Commission expires on KIMBERLY JO BROWN NOTARY PUBLIC OF NEW JEftSEY My Commission Expires April 21. 19!18