ML18100A307

From kanterella
Jump to navigation Jump to search
Submits Suppl Info to Support License Change Request 92-14 Re Reactor Trip Sys Instrumentation,Per NRC 930323 Telcon Request.Procedure Will Be Generated to Test Median Signal Selector Once Per Refueling Outage.W/O Listed Encls
ML18100A307
Person / Time
Site: Salem  
Issue date: 04/13/1993
From: Hagan J
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NLR-N93056, NUDOCS 9304190181
Download: ML18100A307 (2)


Text

10PS~

Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038 Nuclear Department APR'1 ~ 1993 NLR-N93056 LCR 92-14 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

REQUEST FOR AMENDMENT SUPPLEMENTAL INFORMATION REACTOR TRIP SYSTEM INSTRUMENTATION SALEM GENERATING STATION UNITS NOS 1 AND 2 DOCKET NOS. 50-272 AND 50-311 Public Service Electric & Gas Company (PSE&G) hereby submits supplemental information to support the review of License Change Request 92-14 which was submitted February 5, 1993.

This information was requested during a telecon with the NRC on March 23, 1993.

The following documents are contained as enclosures to this letter: -

WCAP-7509-P-A, Isolation Tests Process Instrumentation Isolation Amplifier, Westinghouse Hagan Computer Systems Division, Model 131-110 -

WCAP 11313 - Results of Electromagnetic Interference Tests Applied to the Westinghouse Distributed Processing Family - Westinghouse Letter PSE-ADFCS-93-006, Response to MSS Issue -

PSE&G Nuclear Department Procedure NC.NA-AP.ZZ-0064(Q) Rev. 1, Process Computer Maintenance and Modification Contr.ol Program -

PSE&G Nuclear Administrative Procedure NC.NA-AP.ZZ-0064(Q) Rev. O, Software Quality Assurance 190073 The power is in your hands. <--93o4 i cjc)iaf 930413--

1 PDR ADDCK 05000272 p

~\\

95-2168 REV. 11/91

  • Document control Desk NLR-N93056 LCR 92-14 APR 13 1993 2

Please note that WCAP-7509-P-A is the NRC approved version of WCAP-7509-L which was references in the March. 23 telecon.

A procedure will be generated to test the Median Signal Selector once per refueling cycl~. This procedure will be developed during the d~~igri change installation and technical specification

_amendment implem~ntation.

Should there be' any questions with regard to this submittal, please do not hesitate to contact us.

c Mr. J. c. Stone Licensing Project Manager an ident -

perations Mr. T. Johnson

, Senior Resident Inspector Mr. T. Martin, Administrator Region I Mr. Kent Tosch, Chief New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering

  • CN 415 Trenton, NJ 08625