Provides Addl Explanation & Justification for Deleting Calculated Peak Containment Pressure Value from TS Bases Contained in License Change Request 91-03.Parameter of Importance Is Allowed Design Pressure of 47 Psig
ML18096B253
Person / Time
Site: Salem  
Issue date: 02/02/1993
From: Labruna S
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NLR-N93017, NUDOCS 9302120011
Download: ML18096B253 (3)


Text

.,..

Public Service Electric and Gas Company Stanley LaBruna Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-1200 Vice President - Nuclear Operations FEB 0.2 1993 NLR-N93017 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

ADDITIONAL INFORMATION TO SUPPORT LCR 91-03 BASES CHANGES SALEM GENERATING STATION FACILITY OPERATING LICENSES DPR-70 AND DPR-75 DOCKET NOS. 50-272 AND 50-311 This letter provides additional explanation and justification for deleting the calculated peak containment pressure value from the Technical Specification (TS) Bases as proposed in LCR 91-03.

Our justification contained in LCR 91-03 stated:

"Deletion of the analysis limit for containment pressure does not eliminate any requirement but simply removes the analytical number to avoid the need to modify the Technical Specification Bases every time the peak containment pressure changes.

The parameter of importance is the allowed design pressure of 47 psig, and the Bases still specify that the peak pressure must remain below this value."

The provisions of 10CFR50.36(a) state the following:

"Each applicant for a license authorizing operation of a.

production or utilization facility shall include in his application proposed technical specifications in accordance with the requirements of this section.

A summary statement of the bases or reasons for such specifications, other than those covering administrative controls, shall also be included in the application, but shall not become part of the technical specifications."

As stated in 10CFR50.36, the intent of the TS Bases is to provide the reasons or basis for the associated TS.

The two affected TS Bases sections are those for internal pressure and. for containment structural integrity.

We believe the basis or reason 110037

.. ----~~~21~gg~l' ~~g~g~7;*----~

p PDR

Document Control Desk NLR-N93017 2

FEB 0 2 1993 for the internal pressure TS is to ensure that the containment pressure does not exceed the design pressure of 47 psig during limiting pipe break conditions and that the basis or reason for the structural integrity TS is to ensure that the containment can withstand the design pressure.

The design pressure, not the calculated peak pressure, is the value of significance relative to the basis or reason for the applicable TSs.

The current calculated peak pressure is significant only as it relates to the design value (i.e., the calculated value must be less than the design value).

The. proposed Bases change therefore removes unnecessary information from the Bases and avoids the need to modify the TS Bases every time the peak containment pressure changes.

It should be noted that the Hope Creek TS Bases currently include the calculated peak pressure, and our intention is to remove this calculated value from the Hope Creek TS Bases at the next convenient opportunity.

Should you have any questions or comments on this transmittal, do not hesitate to contact us.

Sincerely, Affidavit C

Mr. T. T. Martin, Administrator - Region I

u. s. Nuclear Regulatory Commission Mr. J. C. Stone, Licensing Project Manager -

Salem U. S. Nuclear Regulatory Commission One White Flint North Mr. T. P. Johnson (S09)

USNRC Senior Resident Inspector Mr. K. Tosch, Chief NJ Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering

I, STATE OF NEW JERSEY COUNTY OF SALEM

)

SS.

)

REF:

NLR-N93017

s. LaBruna, being duly sworn according to law deposes and says:

I am Vice President - Nuclear Operations of Public Service Electric and Gas Company, and as such, I find the matters set forth in our letter dated

, concerning the Salem Generating Station, Unit Nos. 1 and 2, are true to the best of my knowledge, information and belief.

Subscribed this )_hd

/

and Sworn to before me day of k_h r-uo..r~

1993 qfm~ Gl.+lcU My Commission expires on

" (

KIMBERLY A. HILL NOTARY P!_il.1 1 IC OF NEW JERSEY My Corn**

  • **. March 9, 1997

~~~~~~~~~~~~~~~