NPDES Discharge Monitoring Rept for Dec 1992 for Salem Generating Station
ML18096B232
Person / Time
Site: Salem  
Issue date: 12/31/1992
From: Vondra C
Public Service Enterprise Group
To: Caporale G
NEW JERSEY, STATE OF
References
NUDOCS 9302020027
Download: ML18096B232 (27)


Text

,:_'".

OPS~G Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038

  • Salem Generating Station Chief George Caporale Bureau of Information Systems CN-029 Trenton, NJ 08625 January 25, 1993 NEW JERSEY POLLUTANT DISCHARGE ELIMINATION SYSTEM DISCHARGE MONITORING REPORTS SALEM GENERATING STATION PERMIT NO. NJOOOS622 Attached is the Discharge Monitoring Report for Salem Generating Station containing the information as required in Permit No.

NJ0005622 for the month of December 1992.

This report is required by and prepared specifically for the Environmental Protection Agency (EPA) and the New Jersey Department of Environmental Protection and Energy (NJDEPE).

It presents only the observed results of measurements and analyses required to be performed by the above agencies.

The choice of the measurement devices and analytical methods is controlled by EPA and NJDEPE, not by the company, and there are limitations on the accuracy of such measurement devices and analytical techniques even when used and maintained as required.

Accordingly, this report is not intended as an assertion that any instrument has measured, or any reading or analytical result represents, the true value with absolute accuracy, nor is it an endorsement of the suitability of any analytical or measurement procedure.

  • tz~
c. A. Vondra General Manager -

Salem Operations

,'i i-CERTIFIED MAIL RETURN RECEIPT REQUESTED ARTICLE NUMBER: P 708 711 341 Mr. Steve Mathis JAN 0 5 1993 NLR-E92384 HANDLED BY ~.._t __ _

DATE COPIED 1 CJ -3 DATE SENT I - :>-CJ.2J OTHER-----

NJ Department of Environmental Protection and Energy Office of Enforcement Policy Southern Bureau of Water and Hazardous Waste Enforcement 20 E. Clementon Road Gibbsboro, NJ 08026

Dear Mr. Mathis:

SALEM GENERATING STATION NJPDES PERMIT NO. NJ0005622 OIL DISCHARGE TO RIVER CASE NO. 92-12-30-0853-00 A discharge of oil to the Delaware River occurred at the Salem Generating* station on December 30, 1992.

The. oil sheen entered the Delaware River through a stormwater out:fa.11, DSN 488. The sheen, which appeared dark and smoky extended approximately 300 feet downstream hugging the shoreline.

The sheen was also reported to the National Response center which assigned Case Number 151-003.

The U.S. Coast Guard dispatched Petty Officers Kilgore and Lee who inspected the discharge and cleanup activitiese Less than five (5) gallons of oil was estimated to be discharged.

The oil sheen was discovered at 0845 hours0.00978 days <br />0.235 hours <br />0.0014 weeks <br />3.215225e-4 months <br /> during a precipitation event and ~~ported to the Senior Shift Supervisor.

Site Protection,,~nd Site Services personnel immediately took action to install oil~absorbent boom in the Delaware River around.the outfall an&~-in* the last inlet of DSN 488 prior to discharge to the River.

Other inlets into DSN 488 were inspected and no source of oil was identified nor was any sheen observed on the water in those inlets.

The discharge was effectively terminated upon placement of the boom in the River at approximately 1100 hours0.0127 days <br />0.306 hours <br />0.00182 weeks <br />4.1855e-4 months <br />.

I' '

r Mr. S. Mathis NLR-E92384 2

JAN 0 51993 Although the investigation identified no source of oil, the probable cause is oil which leaked to the storm drain system during a dry period and was washed from the system during the precipitation event.

If you have any additional comments or questions regarding this matter, please contact Pat McCabe at (609) 339-1245.

Sincerely,

??~~

Manager -

Licensing and Regulation C

Assistant Director of Enforcement; NJ Department of Environmental Protection and Energy 401 East state street CN 029 Trenton, NJ os6i5-0029 Petty Officer G. Kilgore

u. s. Coast Guard 1 Washingtbn Avenue Philadelphia, PA 19147-4395 U. s. Nuclear Regulatory Commission Document Control Desk Washington, D. c.

20555

.-.(

r Mr. s. Mathis NLR-E92384 JAN 0 51993 3

.jb~l'J*.*

BC General Manager -

Salem Operations (SOS)

General Manager - Nuclear Services (N3S)

General Manager - Environmental Affairs (Newark 17G)

Rad Prot/Chemistry Manager - Salem (S04)

  • Chemistry Engineer -

Salem (S07)

Principal Engineer - Environmental Licensing (N21)

Station Environmental Licensing Engineer -

Salem (N21)

M. F. Vaskis (Newark SC)

R. F. Quinn (S07)

D. K. Hurka (N21)

Microfilm Records Management File 2.1.1 S, 12.1 ATS CLOS:

DEP PM NJOOOS622-06 TASK 0027

~

')...

T *

' r NJPDES' Report December 1992 C EPA-Region II Mr. Gerald M. Ransler - Executive Director USNRC -

Document Control Desk Vice President - Nuclear Operations General Manager -

Salem Operations RP/Chemistry Manager -

Salem Operations Manager-Licensing & Regulations E. Keating M. Vaskis D. Hurka Central Record Facility File RPC93-016

0

,&°JPDES Report Explanation of Deviations December 1992 The following explanations are included to clarify possible deviations from permit conditions.

General -

The columns labeled, "No. Ex.," on the enclos~d DMR, tabulate the number of daily discharge values outside the indicated limits.

Data reporting and accuracy reflect* the working environment, the design capabilities and reliability of the monitoring instruments and operating equipment.

All reported concentrations are based on daily discharge values.

Total residual chlorine is performed three times per week during chlorination unless otherwise indicated.

Analytical values which are less than detectable are reported as zero unless otherwise indicated.

Analytical results for all parameters other than Ph, temperature, TSS, TRC and Bioassay are provided by NET Atlantic, Inc. (NJDEP certification 08153).

Bioassay results are provided by Princeton Testing Laboratories Inc. (NJDEP certification 11118).

Net negative discharge values are reported as negative.

487, 487B-Flow calculated as per permit based on Wilmington NWS 489, 489A Data.

489B 481-486 - Chlorination of the circulation water system normally does not occur except as otherwise noted.

Service water system chlorination is normally continuous and is monitored on the circulating water system outfall.

Chlorination of both systems will be indicated by results reported for both and represents their combined affect upon the circulating water outfall.

COUNTY OF SALEM STATE OF NEW JERSEY I, Calvin A. Vondra, of full age, being duly sworn according to law, upon my oath depose and say:

1.

I am the General Manager of the Salem Generating Station, and as such am authorized to sign Discharge Monitoring Reports submitted to the New Jersey Department of Environmental Protection and Energy pursuant to the station's New Jersey Pollutant Discharge_.Elimination System permit.

2.

I have reviewed the attached Discharge Monitoring Reports.

Pursuant to N.J.A.C. 7:14A-2.4, I certify under penalty of law that I have personally examined and am famillar with the information submitted in this document and all attachments and that based on my inquiry of those individuals responsible for obtaining the information, I believe the submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment.

3.

The signature on the attached Discharge Monitoring Reports is my signature and I am submitting this affidavit in satisfaction of the requirement that my signature be notarized.

Sworn and subscri?T~~~~~~~~ me~

this 1/.,5 day of~r992.

. Ak/IUJ! ;~

My commission.expires tlutJ"/£1/t/'196 Ca v n A. Vondra General Manager -

Salem Operations

  • -*I

., I 4

. *\\'

.ilJJPDES Report Explanation of Deviations December 1992 48C - Non-Radioactive Liquid Waste - This system continues to be operated in a batch mode to treat for hydrazine and ammonia by the addition of sodium hypochlorite.

No hydrazine has been discharged from this outfarl during the reporting period.

Residual chlorine is monitored at the outfalls of DSN's 481, 482, 484, and 485, and has not exceeded the permit limits at these outfalls.

The following excursions are included in the attached report and explained below.

Excursions have not endangered nor significantly impacted public health or the environment.

DMR NO.

DSN-488 EXPLANATION See Attached Report Case No.

92-12-30-0853-00

r

.:.'il2 ** j

...' ~

MONITORING REDQRT TRANSMITTAL SHEET N.Jf'D!S NO.

  • ll'IEl'Oll'ITING PEll'llOO

.. o.

y "*

.. o. ""*

10:01015161212

,ERMITTEE:

Nimi Public Service Electric and Gas Company Hancnbk's Bridge. New Jersey FACILtTY:

N1tnt Salem Generating Station

  • Addms Al 1 QWflJl Creek Neck Road Hancock's prjdqe Telephone (609 l 935-6000 FORMS ATTACH EC (/Nlimt~ Qua1Trirv of Each)

SLUDGE l'IEPORTS

  • SANITAl'IV DT-VWX-007 DT*VWX-008 DT*VWX.()09 SLUDCiE AEl"Ol'ITS *INDUSTRIAL DT-VWX*010A DT*VWX-0108 WASTEWATER REPORTS Or-vwx-011 DT-vwx-012 Dr-vwx-013 GROUNDWATER l'IEl'Ol'ITI

!County! Salem OPERATING EXCEPTIONS DYE TESTING TEMl'OlllAl'IY IYPASSINCi DISINFECTION INTEAAUPTION MONITOl'llNCi MALFUNCTIONS UNITS OUT OF OPERATION CTHE,.

(DerlJiJ MY.. Ya" on n~r sid~

In llPPrDPrillt~ rpoa.J Frgi..;ra 3 YH HO CJ EJ D

!El D

lEJ D

mJ D

El 0

I!l Ovwx.01s1A,BI Ovwx-01&

Ovwx-011 Nl'DES DISCHAAGi; MONITORING REPOAT..

I 111 EPA FORM 3320-1 NO'l'E: The.. Ho:.rn AnmdM m lltmr" on iM

-;;;;;;;'of tis.ii lh<<t maut obo k compln1d.

AUTHENTICATION

  • I certify under penalty of law. that I have personally examined and am familiar with the information submitted in this document and all attachments and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting false information including the possibility of fine and imprisonment.

LICENSED OPERATOR N1me (Printtd)

David K. Hurka

. d G"d' & R*g;V,_** :::z.._N-684-Y Si;n1turt 6,....:__

~ /274 om J-o ?('

7.5" 19 2 3

)

I PRINCIPAL EXECUTIVE OFFICER or OULY AUTHORIZED REPRESENTATIVE N1mt (Print<</} _c_._A_._v_o_n_d_r_a ________ _

Titlt (Print<</}

erations 24

I IL

./

OPERATING EXCEPTIONS DETAILED

.DSN 487 and 489 -

Sample5 were obtained and* reSults reported fqr COP Iptake. Net, and Effluent Haweyer chlqrjde iriterference with the analysis renders the resftits

  • meaningless for practical purposes PSN 4897\\ -

Wa5 put pf seryjce for wejr repajr. there were nq discharges during the reporting period IiSN 489B -

Page 17 << *parameter 32 I cop; 5amp] e was obtaj ned anrj ng the reaorting period for COD. Valid results we~e not obtained due to chloride interference in excess of lOOO*ppID.

Sample was also.obtained for TbC analysis.. the result was 4 ppm.

DSN482A *and 483A - Thermal RTD's were* out of service for part of the reporting perjgd. Data used was taken from Operations hourly logs.

DSN 485A - Thepnal RTD was out of service for the entite0reportinq period. Data used was takep frpm-Operations hourly Jggs.

HOURS ATTENDED AT PLANT Month l.JJLI.

Year lillJ Day of Month*

1 2

3 4

5 8

7 8

9 10 11 12 13 14 15. 16 Licensed Oper1tor 8

8 8

8 8

8 8

8 8 8

8 8

  • Others 4

4 4

4 4

4 4

4 4 4

4 4

Day of Month 17 018 19 20 21 22 23 2* 25 26 27. 28 29 30 31 Licensed Operator 8 8 8

8 8

8 H 8

8 8

8 Othen 4 4 4

4 4

4 4 4

4 4

4 25

PERMITTEE NAMlt/ADDRltSS {Include Facility Name/Location if dlff~rent)

NATIONAL P'OLLUTANT DISCHA"GIE !ELIMINATION ll:YSTIEM (NPDESJ DISCHARGE MONITORING RIZPOl'lT fDMRJ

~Ma: __ _f_SE&G _. -------------------------

ADDft!!! _ _f_!J!.'!-....BO>i_23~N2~-----~~

____ _l!ANCOCKLBRIDGE:t.N_.J--'08038_; __

2-16 17-19 NJ0005622..

FACA PERMIT NUMBl!i:R ::

t---------t PARAMETER (32-37)

EMPERATURE, WATER EG* CENTIGRADE 0010 1 l EFFLUE~fT GROSS VALUE,.

EMPEH.ATUREt WATER EG* CENTIGRADE 00010 2 1 EFFLUENT NET VALUE EMPERATURE, WATER DEG. CENTIGRADE';

00010 7 1 INTAK~ FROM STREAM MONITORlfiG PERIOD I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY. EXAMINED.'

AND AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN: AND':BASED' ON MY INQUIRY, OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FO!f*;

OBTAINING THE INFORMATION.

I BELIEVE THE SUBMITTED INFORMATION*'

IS TRUE. ACCURA.TE AND COMPLETE. I AM AWARE THAT THERE ARE.SIG;*,

Form Approved.

OMB No. 2040-0004.

Approval expires 6-30-91.

THeRMAL DSCHG f.OR.DSN.. 481-483 MA~OR

  • SALEH l.,.*

SOUTHERN R:EGIO~

NOTE: Read instructions ~fote co~pletihil'fhis fO'rm.

(69-70)

c. Vondra G.M.- Salem Ops.

~~~c~~~s1~~7;; T~i FiN~R A~g~;;:~gN::;~E s~~F~~M~-~~N. I l~~,u~~g: 1-'-'~Y:--Ll!:i-.r-(:-.:.......::..;,.:.=--==---i o I 25"

'33 USC § 1 319. f P;1naltic*,.., Ufl(Jt'r tht>flf' atatutt'H nra,v inrludr finrH up (fl l/fJ.fHHI a1ul ur maximum inrprism1nr1*11f of ht*fu*t',..n 6 mtmths and.5.\\'t'Ortf..J YEAR MO DAY TYPED OR PRINTED OFFICER OR AUTHORIZED AGENT NUMBER

~~EtJeN'T E'f'~T 1 i"S 0 'TtrvB'f?Lt1At."eUf."~'T'E"D' 11 l{Sc"TffE"*'ctOMBINED AVERAGE OF EACH OF THE SEPARATE DISCHARGES 481-483.

NET TEMP DIF IS THE DIFFERENCE BETWEEN THE AMBIENT RIVER WATER TEMP AND THE AVE EFFLUENT TEfllP OF 481-483*

EPA*Form 3320-1 (Rev. 9*88) Previous editions may be used.

P'AGE 1 Of 17

PERMITTEE NAME/ADDRESS (Include Faciliry Name/Locarion ~different)

NATIONAL POLLUTANT DISCHAftGE l!:LIMIN"'!ION *Y*TKM,,,ru~~I DISCHARGE MONITORING REPORT fDMRJ

!!.J>,ME __ ~~~b~--~~-----~-

ADE_!!!!!~__f_*0!__BQ~23fi[N2~---~~-*---

~6 1~n N.J0005622 FACB


1 Form Approved.

OMB No. 2040-0004.

      • Approvarexpire's 6-30-91.

____ _liANCOCKLBRID6EdJ_0803f!._:-___

  • PERMIT NUMBER PARAMETER (32-37)

EMPERATURE7 WATER DEG* CENTIGRADE 00010 1 1 FFLUENT GROSS VALUE,,rn~~~,

TEMPERATURE, WATER E.G* CENTIGRADE 0010 2 1 FFLUENT NET VALUE EM?ERATURE, WATER DEG* CENTIGRADE*

00010 7 1*

INTAKE FROM STREAM

c. Vondra G. M. -

Salem Ops.*

.. TYPED OR PRINTED THERMAL MAJOR SOUTHERN DSCHG FOR.DSN 484-486

  • .SALEM REGION NOjE: Read instruction*before completihg'this ~rm.

(3 Card Only)

QUANTITY OR LOADING (4 Card Only)

QUALITY OR CONCENTRATION (JS-45)

(4~3)-..

(S_4-6_J~)--~----l NO. FREo:;:NCY SAMPLE (4~53)

(54-61)

EX ANALYSIS TYPE xx.M.f ~aM::xx xx.~e-¥~xx x~~xx uN1Ts 62-03>

<69_70>

.. I :CERTIFY UNOER**PENALTY: OF LAW THAT I HAVE PERSONALLY.:EXAMINEQ... '

ANO AM FAMILIAR WITH. THE INFOR!AATION SUBMITTED HEREIN: AND' BASEO,;o.

ON... MY INQUIRY :*oF Tt!OSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR'c*:'

.. OBTAINiNG THE *iNFORMA'rlON, I BELIEVE THE.SUBMITTED INFORMATION

  • 20.9.

IS TRUE. ACCURATE ANo:*coMPLETE. l***AM *AWARE THAT THERE.* ARE SIG*:-

NIFICANT. PENALT:IES );'Oli:, SUBMITTINCf FALSE **INFORMATION._ INC(:UDING:':'.~~~~.,_,_¥-,/..it~~~~~.... =.-~

THE POSSIBIUTY *oF FINEANO IMPRISONMENT. SEE 16 U.S.C

§ 1001 ANO*:

33 USC § 1 319.. f Pt>naltic>.'I undt>r thf'sf' atatutt's ma.v inrludf' fint>H up '" llO,lHHI 609 a1u:I ur ma.rim um i~ipriHcmmn1/ of hf'tU*ffn 6 monthH and S,\\'f'GrN.I OFFICER OR AUTtlORIZF.:D AGENT 0/ '25""

NUMBER

  • YEAR*

MO

.DAY

~P'Etleflif"EXf~T*CfS 011"tflYl)'f=>Lt'"M.~Uf!ATeD' 11 ft51'"fffFe'COM.BINED AVERAGE OF EACH OF THE SEPARATE DISCHARGES 464-486.

NET TEMP DIF IS THE DIFFERENCE BETWEEN THE AMBIENT RIVER WATER TEMP*AND THE AVE EFFLUENT TEMP OF 484-486*

EPA*Form 3320-1 (Rev. 9-88) Provious editions may be used.

L lfc:.EPJ.ACES EPA FORM T*CO WHICH MAY NOT. EE.USED.)

/ 73~ 7 AB:>:

PAGE 2 OF' 17

PERMITTEE NAME/ADDRESS {Include Facility Nam,e/Locatlon if different)

~----....f..s.E~---------------*---------

ADDftEn_....:e_~~-]!.Q~~~N2.l._ ____________ _


~~m~~_RIDGE~L0803L ____ ~

NATIONAL POLLUTANT DISC:HAllGlll: IELiMINATIOI~ SYSTEM (NPDESJ DISCHARGE* MONITORING REPORT fDMRJ

~~

JN9 NJOOD5622 FACC 1--------1

  • PERMIT NUMlllER;'.*
  • THERMAL MA~OR Form Approved.

OMB No. 2040-0004.

  • Approval expires S.:30-91.

DSCHG FOR DSN.481-486

> SALEM FACIL!r! __ _f_SEf;.G2ALEM. GENERAT:IN~STATIOL LOCATIO~..J...Oi!!ER_ALLOWAYLCREE.NL0803L_

SOUTHERN ~EG:ION mm NUf'lBER: 9.2120268 NOTE: Read instruction~ before ccimpletihi11his fe)rm.

PARAMETER (32-37)

HERMAL DISCHARGE MILLION BTUS PER HR*

00015 2 0 EFFLUENT NET VALUE

c. Vondra G.M.- Salem Ops.

TYPED OR PRINTED (3 Card.Only)

QUANTITY OR LOADING (4 Card Oniy)"

QUALITY OR CONC!l:NTRATION (46-53)

(54-6/)

(38-45)

(46-53):.

(54-61)

NO *. FRE~:NC:Y SAMPLE t-----~---r------:--.------t-----~--.------.. ---.---. -----.--.------; EX.": ANALYSIS TYPE v:~~il<XX X~°4><"J>Oa:~>~x uN1Ts X'AM~)(fl@(XX x~~li.$<XX.. x~j~~x 25106 I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED AND AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN: AND BASED ON MY INQUIRY. OF *:J'HDSE INDIVIDUALS IMMEDIATELY RESPONSIBLE. FOR OBTAINING *THE INFORMATION.

I.BELIEVE THE* SUBMITTED INFORMATION

    • .t

~Fl~~~~ ~~~~~~~~ A~gR C~~~~~N~ A~AL~~A~~F~~~:T;~~.REIN~~~;;~~ h/:i>/,l.'U'/!J.'-:.?..J.~CL.'#1-~~~~~_::i THE POSSIBILITY :oF FINE AND IMPRISONMENT. 'SEE 1 B U.S.C

§ I 00 I AND 33 USC § 1319. f Pf'na/tit*,., untit>r tht'HP atatulf'H nra,v inrludr finf'H up '" I lfl,Otltl and ur maximum impriHtmn11*111 u{ h1*tu*t't'n fi m11nthr1 and.~,\\'f'dfH,J AUTHORIZED AGENT O I 25" NUMBER YEAR MO DAY COMMENT AND EXPLANATION OF ANY VIOLATIONS (Reference t1ll uttachmenls here)

EPA*Form 3320-1 (Rev. 9-88) Provious editions may be used.

(REPLACES EPA FORM T-*o WHICH MAY NOT BE USED,J /1 "!12 7

_o_~_, ~ 3 __

LABS:

PAGE 3 Of' 11

FA.c1L1TY_...f.SEE;G ~ALEH :J!.ENERATING._STATIO?L_

LOCATIO~....!::.OWER.....B_LLOWAYLCREE:t!i.J_:._0803L_

DMR NUMBER: 92120263 NATIONAL f'OLLUTANT DISCHAftOE ELIMINATION SYSTEM (NPD£S)

DISCHARGE MONITORING REPORT fDMRJ FROM 2-J6 17-19 NJ0005622 48CA PERMIT NUMltli:ll

~DISCHA"GE NUMal:R_

Form Approved.

OMB No. 2040-0004.

App.roval expires S:.30--91.

~---M-O_N_l_T_O_R"""l-N-.G-P_E_R-I0-0----. NON-RAD IO LOGICAL WASTE TREAT**

MAjOR 1

SALEM r-c;.,,.-t-'t..,._t--"!~ SOUTHERN R~GION NOTE: Read instructions.before c:Ompletih*irth'is Jo.rm.

,I:./

(3 Card Only)

QUANTITY OR LOADIN'G (4 Card Only)'*

QUALITY OR CONCENTRATION (46-53)

(54-61)

(38-45)

(46-53)..

(54-61)

NO. FRE~;NCY SAMPLE PARAMETER (32-37)

XYGEN DEMAND, (HIGH LEVEL) (CUD) 00340 1 1 EFFLUENT GROSS OLIDS, TOTAL SUSPENDED 00530 1 0 EFFLUENT GROSS VALUE YDROCARBONS,IN~Hzo, IR,CC14 EXT* CHROMA 00551 1 0 EFFLUENT GROSS.VALU FLOWy IN CONDUIT OR HRU TR.EATjqENT 'PLA 50050 1 0 EFFLUENT GRDSS BIO ASSAY (96 HR.)

61402 *1 l EFFLUENT GROSS VALU NITROGEN,.AMMONIA TOT.AL (AS NHlf) 71845 1 0 EFFLUENT GROSS

c. Vondra G.M.- Salem Ops~

'TYPED OR PRINTED l----'--~-~------_;..--~---~--'-----'---~------'----.---'*--'---~----1 EX ANALYSIS TYPE xxw~6~xx X'A.Y.u<!Nli~~xx

  • uN1Ts X~.t!N.~M~xx XY..4*~~xx.x~l'.M:XX UN,iTS 24 27

~NE'!! AO~f.VL~JtR't~t.'Y v~PmfrI<<ffi'e'TS'"F<EQu'IWfD FOR BIOASSAYt ENTER* "NODI" FOR MONTHS WHEN BIOASSAY NOT TAkEN*

EPA*Form 3320*1 (Rev. 9*88) Pfflvious editions may be used.

PAGIC 4 OI' 17

PE:RMITTEE l'tAME/ADDIUtSS (Jncluae FacUlty Name/Location i dlffoent)

~--_f.~&G_*-------------------------

ADD"!!!_-.f.*O~B0~23~N2!_ ______ _

.J!ANCOCKLBRID6Etf!.J~0803iL_ __ _

NArlUNAL P'OLLUTArtT Ltla\\.::rt,..H'iill. a.L.1Ml,.A"l'IOh *Y*l.*M 11*rUCJJ DISCHARGE MONITORING RE:PORT fDMRJ 2~6 1N9 N-10005622 lf81A 1--------

PERMIT NUMBE" MONITOR.ING*PERIOD Form Approved.

OMB No. 2040-0004.

Approval ex.pires 6-30-91.

N01'~CONTACT-COOLING.WATER MAJOR

. **SALEM SOUTHERN.REGION NOTE: Read instructions before completiktjfthis fe)rm.

..I:

PARAMETER (32-37)

(3 Card Only)

QUANTITY OR LOADING (4 Card Oiify)

  • QUALITY OR CONCENTRATION *

(46-53)

(54-61)

(38-45}.

(46-$3)*..

(54-61}

NO. FRE~:NCY SAMPLE l----'---'-----,.--'---'----,-----+--'----'----,....------'----.-----'*--'---~-----1 EX ANALYSIS TYPE

-.,.~x,w:l{~~xx x~~m~ uN1Ts XY.Mc~ii,n~:.xxx :<~'!Vitfff'A~xx -X~lOfl.¥.XX uN1Ts (69-70)

PH 00400 1 0 EFFLUENT GROSS VALU PH 00400 7 0 INTAKE FROM STREAM FLOW, IN CONDUIT OR HRU TREATMENT PLAN 50050 1 0

  • EFFLUENT GROSS VALUEkt HLORINE, TOTAL RESIDUAL 0060 R 1 EE COMMENTS BELOW CHLORINE, TOTAL RESIDUAL 50060 s 1 SEE COMMENTS £ELOW CHLORINE, TOTAL P.ESIDUAL 50060 T 1 SEE COMMENTS BELOW
  • c. Vondra G.M.- Salem Ops.
  • _TYPED OR PRINTED 6.5 I CERTIFY UNDER PENALTY. OF LAW THAT I HAVE PERSONALLY. EXAMINED":*

AND AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN: AND-*OASED ON MY. INQUIRY "OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR.

OBTAINING THE iNFORMATION." I BELIEVE THE SUBMITTED INFORMATION 6.8 IS TRUE. ACCURATE AND COMPLETE. I AM AWARE THAT THERE ARE SIG-*:1 _,~~u,_~~Zt;~~~~-~~

NIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION. *INCLUDING !-

THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 16 U.S.C

§ 1001 AND 33 USC § 1 319. f Pt'nalti<'."I untit'r tht.*f' statult's ma,v inC'ludt' f,'nn1 1.JP to $J(J,(HHI 011.d ur maximum iriipri:w11nw11t uf hf'IU. 1t"f'n 6 munt.h1' and /j :i*ParH.I C?fFIC.ER ~R AUTHORIZED AGENT Cf9!l'~m.fe""fl:l'{xP5'00f;I~ f.'OCA""'fll1l~sn~re1!fe "SlUS'""'USCRG (NO CWS FLOW)

ENTER "NODI" FOR LOCATIONS THAT DO NOT APPLY*

  • s* = SWS DSCHG"(NORMAL COND)

NUMBER YEAR MO DAY 11T" = CWS DSCHG WHEN MAIN CONDENSERS ARE CHLORINATED, MONITOR TRC 3 TIMES PER WEEK DURING 2~HR PERIODS Of CHLORINATION.

EPA*Form 3320-1 (Rev. 9-88) Provious editions may be used.

P'AGI!

5 OI' 1"1

PERMITTEE NAME/ADDRESS (Jncluae FacUity Name/Location If different)

~---~s_f~G--------~~--

ADDftEn _

__f_eO!_BOK._~Ql.N21.___~~-~~-


~~rncKLBRIDGE~L0803L __ _

FACILl~-~~&G~ALEM~ENERAUN~STATIU~

~ocAT10~...1..!J.MEL..8.LLOWAYS....CREEt_N-!_080 3L_

DMR NUMBER: 92120268 NATIONAL. POLLUTANT DIS\\;H.... NU& &LIMINA~ION aYa.l&M f"TU~.J/

DISCHARGE MONITORING REPORT (DMRJ 2-16 17-19

    • NJ0005622 lt82A PERMIT NUMllER
  • or*CHARGE HUM*~~:

Form Approved.

OMB No. 2040-0004.

Approval expires 6-30-91.

NON-CONTACT CO.CLING WAT.ER 1----.--M_O~N_I T_O~R"'-.-*. _IN_. G..,..;:-_:P_E"""R_l~O..... o_-.---....1**'

  • MAJOR SALEM r.-a_,,.--t""'.,-;---=t1..., *SOUTHERN REGION.

~*

NOTE: Read inltructioni before ccimpletln-g'this fOi.m.

PARAMETER (32-37)

(3 Card Only)

"QUANTITY OR LOADING

  • (4 Card Ohly).'*_

QUALITY OR CONCENTRATION NO.. FREQOUFENCY (46-53)

(54-61)

(38-45).:-.

(46-53)'.-

(54-61) 1----'--"'---~--'----'-----.-----+--"'----"--"""T""--'-------r---*-~--..----~ EX._*: ANALYSIS SAMPLE TYPE PH 00400 1 0 EFFLUENT GROSS VALU PH 00400 7 0 INTAKE FROM STREAM FLOW, IN CONDUIT OR THRU TREATMENT.',~PLAN 50050 1 o.

EFFLUENT~~OSS~VALU

.HLORINE7 TOTAL ESIDUAL.-

50060 R 1 SEE COMMENTS BELOW CHLORINE, TOTAL RESIDUAL 50060 5 1 EE COMMENTS DELOW CHLORINE.,. TOTAL RESIDUAL 50060 T 1-SEE COMMENTS BELOW

c. Vondra G. M. -

Salem Ops*.

TYPED *OR PRINTED

>~X#)!fa~'lo~xx X~t'!l1l:tb~(XX uN1Ts

  • x~_j(,)(w~xx x~~~xx. X>@4x.uow.xx uN1Ts I CERTIFY UNDER PENALTY OF LAW THAT** I HAVE *~ERSONALL:v E.~AMiNED; AND AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN: AND. BASED" ON MY INQUIRY OF '.THOSE INDIVIDUALS IMMEDIATELY RESPciNSIBLE..'FOR:

OBTAINING THE INFORMATION.

I BEllEVE THE. SUBMITTED INFORMATIOril 6.7 IS TRUE. ACCURATE "ANO *COMPLETE. I AM AW... RE:.THAT.THERE ARE::s1a:;* F~~~~~~~~~~~~..;;..---1 NIFICANT PENALTIES :"FOR SUBMITTING FALSE: INFORMATION,

  • INCLUDING r THE POSSIBILITY OF FINE ANO IMPRISONMENT. SEE -18 U.S.C t 1001 ANO 33 USC§ 1319.

IPt'naltir.~ undt>r thr.11e statult'a ma,v inrludr finf'H up to SWJHHI at&d or maximum impri.'ltmm.-111 uf ht'lu*t'f'n fi month11 and,:;.\\~Orfll.I

. NUMBER YEAR MO DAY

~~~'11E"r~~xP5tttlfJBN f.'OeA'YfONis<:' 5*~re~ Sllf!:f"T15CHS (NO CWS FLOW)

ENTER "NODI" FOR LOCATIONS THAT DD* NOT APPLY*

n5* = SWS DSCHG.

"T" = CWS DSCHG

~lHEN MAIN CONDENSERS ARE CHLORINATED, MONITOR TRC 3 TIMES PER WEEK DURING 2-HR PERIODS Of CHLORINATION.

EPA*Form 3320-1 (Rev. 9*88) Previous editions may be used.

(R_EPLACES EPA FORM T*40 WHICH MAY NOT BE USED,) Ll"':l. :2. 7

() 't Is 7..

LABS:

~---- ------- -

~---

---~-~-

-~--~

l'AGE 6 OI'" 17

P'ERMITTEI!: NAME/ADDRl!:SS {lncludt Fac/Jlty /{amt/Location If dlfftrtnt)

~~~-.f.SE&6~~~~~-~--~--

ADDftEn _

_f_'!J!.~B0!_.23t!l_N2~-----~-

____.J!ANCOCKLBRIDGEt.N_J---'-0803i!L_: __ _

NATIONAL P'OLLUTANT DISCHARGE ELIMINATION SVSTll:M (NPDESJ DISCHARGE MONITORING REPORT fDMRJ

~16

/~19 N~0005622

~83A

  • PERMIT NUM115:R i----------1 "DllCHARGE NUMal:lt NON-CONTACT HAJ.OR MONITORING*PERIOD Form Approved.

OMB No. 2040-0004.

Approval expires 6-30~91.*.

  • COOLING WATER
  • .SALEH SOUTHERN REGION NOTE: Read instructions before co.Jlplatihi11his to"rm.

H PARAMETER (32-37) 0400 1 0 EFFLUENT GROSS PH 00400 7 0 INTAKE FROM STREAM FLOW, IN CONDUIT OR THRU TREATMENT PU\\

50050 l 0 EFFLUENT GROSS VALU CHLORINE, TOTAL RESIDUAL 50060 R 1 SEE COMMENTS BELOW CHLORINE, TOTAL RESIDUAL 50060 s 1 SEE COMMENTS BELOW HLORINE,.TOTAL RESIDUAL 50060 T 1 SEE COMMENTS BELOW

c. Vondra G.M."'."' Salem Ops.

'TYPED OR PRINTED (3 Card,_;Only)

.QUANTITY OR LOADING (4 Card:OnJyF.'

QUALITY OR' CONCENTRATION N. :

0

F~~Q-UENCY (46-53)
      • "(54-61:)
  • .* (fB-45)
~

(46-53)/

(54-61)

OF I---'--"'-----.--'----'---'--,..-.....;.;_--+-,--::...,,... --=----r-------_..;..__,..;.; _ __; __....:..,. __

T"'"" __ --t EX ANALYSIS

"'<XW~((XX x~.M~>~x ~.N1Ts XYM~)(M{XX

  • X~)(ff4~Xx.*x~~xx I CERTIFY UNDER PENALTY OF. LAW THAT I HAVE PERSONALLY EXAMINED*

AND AM* FAMILIAR WITH THE INFORMATION **SUBMITTED HEREIN, AND BASED.

ON MY INQUIRY. OF THOSE. INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR':

6.7 UNITS OBTAINING THE' INFORMATIO;\\I, I

BELIEVE. THE*: SUBMITTED INFORMATION IS TRUE. ACCURATE AND COMPLETE. l'AM AWARE THAT THERE ARE SIG7:

609.-935;...600 NIFICANT PENALTIES "FOR SUBMITTING. FALSE' INFOF>MATION, 'INCLUDING.' ~~f:.f~~~~~~~~~~--1 THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE* 18 U.S.C

§ 1001 AND" 33 use§ 1319. rPenaltie11 uruirr th,.~ *lalult'B ma.Y inrludr /inl'H up,,, IW,IHHI at&d ur maiimum imprism1mr11I of_hrtu*wn fi mon~hH and,; :r'?'!U O,FFICER OR AUTHORIZED.. AGENT NUMBER YEAR MO SAMPLE TYPE (69-70)

DAY

'f'W~rme-reRXPS'{W"SSN e.'OeA"JV.m~s*"*"!f.<' SWS'h'DSCR'G (NO cws FLOW)

  • ENTER 0 NODI° FOR LOCATIONS THAT DO NOT APPLY*

115* = SWS DSCHG

  • r*.= CWS DSCHG WHEN MAIN CONDENSERS ARE CHLORINATED, MONITOR TRC 3. TIMES PER WEEK DURING 2-HR PERIODS OF CHLORINATION*

EPA*Form 3320*1 lRev. 11*881 Previous editions mav be usRd.

IRll:l'l..ACE!I l[PA l"ORM T**ll WHICH MAY NOT *If USl[D.I I ") ~ ~. 7

" 9' I C:'"'W,

PERMITTEE NAME/ADDRESS {Include Facility Name/Location ~different)

!!.M!!.! __ _f_!L_&G ________

NATIONAL. POLLUTANT DISCHAl'IGIE ELIMINATION SYSTIEM (NPDESJ DISCHARGE MONITORING REPORT (DMRJ 2-16 17-19 NJ0005622..

484A

  • Form Approved.

OMB No. 2040-0004.

ADDft!!!_..f..*0!...__B0~23~N2~-------

__!!MCOCKLBRIDGE~.J_:__0803f!___ __ _

l-'---'-':..:;,_-----1 PERMIT NUl'tlllEft*,". *

  • * *
  • Approval expires 6-30-91.

NOfr'CONTAC'.f COOLING.WATER MAJOR I

.. ;. SALEM SOUTHERN REGION NQjE: Read instructionibefor~ co~pfotHfgthis IO°rm.

Pf-I PARAMETER (32-37) 0400 1 0

'"FFLUENT GROSS 0400 1 0 INTAKE FROM STREAM LOW, IN CONDUIT OR HRU TREATMENT.*PLAN 50050 1 0 EFFLUENT GROSS VALU HLORINE,* TOTAL ESIDUAL 0060 R 1 SEE COMMENTS BELOW CHLORINE, TOTAL RESIDUAL soo6o s* 1 SEE COMMENTS DELOW CHLORINE, TOTAL RESIDUAL 50060 T 1 SEE COMMENTS.BELOW

c. Vondra G.M.- Salem Ops.

TYPED OR ~RINTED (3 Card Only)

QUANTITY OR LOADING (4 Card *Ori/y)

QUALITY OR CONCENTRATION (46-53)

(54--f;J)

. (3~-45)

. (46-53}-

(~l)

NO *. FRE~~NCY l---...:,__.:;....__......,~__;:....__.:._~....,..----+-:-""'""'":........._..:; __

-r-_-------'---""T"""-~"-....:....-~..----'"'--1 EX ANAL. YSIS x~~~'6~XX X~M\\1f.C:Or¥.XX UNITS XXM-!IQf~XX XXr*~XX x~~xx I

. 6. 8' I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED.:

AND AM. FAMILIAR wtn1 THE INFORMATION SUBMITTED HEREIN; AND'.'BASED *'

  • ON' MY., INQUIRY*.OF THOSE INDIVIDUALS 1¥MEoiATELY RESPONSIBL~ FOR,:;

OBTAINING THE ***1NFORMATION.

I BELIEVE. THE *SUBMITTED INFORMATION*,.

IS* TRUE. ACCURATE AND COMPLETE. I AM AWARE THAT 'THERE ARE SIG:*:

NIFICANJ:

PENALTIES :FOR SU.BMITTING* FALSE INFORMATION. *INCLUDING'::h;~~~~n~~:[l!i!~~~~--l THE POSSIBILITY OF FiNE AND IMPRISONMENT. SEE 18 U.S.C

§'1001 AND:;

33 use§ 1319. IPt'nalli<'.'I untit'r thttsf' atalult'll ma,v inrludt' {int'# up'" IUJ,(HHI ali.d or m~.rimum imf'ri:mnmf'l1t uf ~f'IU 1t't'n fi month1' and.5.\\*pars.I UNITS

".. NUMBER YEAR MO SAMPLE TYPE

~DAY

~~~~llf;;\\XP~ljSN £.~ivHJ~Sftf{ftre~ "Sl\\l'S"'DSCRG (NO cws FLOW)

ENTER

~NODI" FOR LOCATIONS THAT DO NOT APPLY*

"T" = CWS DSCHG imEN MAIN CONDENSERS ARE CHLORINATED, "ONITOR TRC 3 TIMES PER WEEK DURING 2-HR PERIODS OF CHLORINATION*

EPA*Form 3320*1 (Rev. 9-88) Previous editions may be used.

(R!i.,Pj,ACES EPA FORM T*40 WHICH MAY NOT BE USED.I f 1°!>!2_7 0 ~I $' ~

LAH~:


------- ------- --~- -------

PAGE 8 OI' 17

PERMITTEE NAMEfADDRESS (Include Facility Name/Location I/different)

~--....f.s..E.&!i. ____________ _

ADDftED _

_f_~~iliJ.~~ql_~l_-----------*-

-1:1AfitiltK~_J!R.IDGEl.N.-l..:_0803lL._ ___

NATIONAL P'OLLUTANT DISCHAllGIC ICLIMINATION SYSTICM (NPDESJ

. DISCHARGE MONITORING REPORT fDMRJ 2-16 17-19

.U0005622

~4~8~5~A"'---~

PEPlllUT NUM*&:R:

NON--CONTACT 1---......---~-~-.,...;.;--~.__~-"""' * "AJOR Form Approved.

OMB No. 2040-0004.

Approval expires 6-30-91.

COOLING WATER S~LEM FAc11...!!:! _ _e_SE£.G2ALEM* 6ENERATING_STATl:OP.L:_

1..ocAT1o~_bQMIB_ALLDWA'Y!L_CREErl!_-!_080 3L_

DMR NUMBER: 92120268 SO~THERN REGIQ~.

PH PARAMETER (32-37)

OOlt-00 1 0 EFFLUENT GROSS VALU PH 0400 7 0 INTAKE FROM STREAM FLOW, IN CONDUIT OR THRU TREATMENT '.... PLAN 50050 1 (}

EFFLUENT GROSS VALU CHLORINE, TOTAL RESIDUAL 50060 R 1 SEE COMMENTS BELOW CHLORINE, TOTAL RESIDUAL 50060' s 1 SEE COMMENTS BELOW CHLORINE, TOTAL RESIDUAL 50060 T 1 SEE COMMENTS BELOW

c. Vondra G.M.- Salem Ops.

TYPED. OR PRINTED NOTE: Read inttruction1 blifo.re completihil'this fc)rm.

(3 Card Only)

QUANTITY OR LOADING (4 Card Only)

QUALITY OR CONCENTRATION (46-53)

(54-61)

(3845)..

(46-$3)*.

(5U/)

NO. FRE~FENCY 1----=--'---~------'---~----+--'---..:.---..-----'--'---""T""---'*--'---~-'----t EX ANALYSIS SAMPLE TYPE

'!'.XhV~~xx X~li~xx uN1Ts XYMU;lqUM<XX x~~}ifi<XX x~>o@t.xx 6.4.

I CERTIFY UNDER PENAL TY Of LAW THAT I HAVE PERSONALL'if E)<AMINED:

~~D MAYM l~~~l~:Ro~

1 1j4H6~~* lr:i:i~~!~N l~~~~:~~~y H:~~::i~L~~~~

OBTAINING THE INFORMATION.

I BEL;IEVE THE* SUBMITTED INFORMATION IS TRUE. ACCURATE AND COMPLETE.. I AM AWARE THAT***.THERE ARE SIG*

NIFICANT PENALTIES. FOR SUBMITTING FALSE: ml'ORMATION.: INCLU0.NG THE POSSIBiLITY.:OF :l'INE AND IMPRISONMENT. '.SEE* 10 U.S.C I 1001 ANO.

33USC § 1319. fPt'nalti<'.'f undt>r thr11P *latutt's nra,v inrludr finr" up 111 IW,IHHJ and ur maximum inrprirumnrrut uf ht'IU*t'f'n 6 month re and S.w*ar,,,J 6.9 o.FFICER.OR AUTHORIZED. AGENT UNITS (69-70)

GRAB 0 I 2.b NUMl!IER.

VEAR MO DAY

~~A~~e~xPSWfilBN f.'Ot"#t'-rlq}~ 5tf~<ffre~ 'SW5c11'D'SC'NG (NO CWS FLOW)

ENTER nNODI" FOR LOCATIONS THAT DO NOT APPLY*

11511 = SWS DSCHG (NORMAL COND)

"T" = CWS DSCHG WHEN MAIN CONDENSERS ARE CHLORINATED, MONITOR TRC 3 TIHES PER WEEk DURING Z-HR PERIODS OF CHLORINATION*

EPA*Form 3320-1 (Rev. 9-88) Prsvlous editions may be used.

""GI 9 OP 17

P'Ac1L1TV _

_f_S E&G 2_ALEM _§_ENERATIN~S.TATION~

' LOCATI0~...1:..0 WER _8_LLOWAY!i__CREEiliJ---0803l!..._.i~

mtR NUMBER: 92120263 NATIONAL P'OLLUTANT Dl9CHAllOIE !ELIMINATION SYSTEM (NPDESJ DISCHARGE MONITORING REPOFtT fDMRJ 2-16 17-19 NJ0005622.

486A 1---------1 PERMIT NUMlltER

  • 0 DISCHA.. GE NUM8Elt Form Approved.

OMB No. 2040-0004.

..... Approval expires 6-30-91.

NO~CONTACT COOLXNG,WATER f---~-M_O~N-*T~O~R_._IN'-. G_P_E_R_*~o_o_~-.:...i.. MAJOR

  • $ALEM SOUTHERN R'EGION.....

NOTE: Read instructiont:*~fo'ie ;x;mpletfr1jp:his fO~m.

(3 Card. Only)

QUANTITY OR LOADING (4 Card* Only)

QUALITY OR CONCENTRATION 17

  • PARAMETER (32-37)

(46-53)

"(54-61)

. C:~B-45)

(46-53);.'

(S.Ul)

    • . No." FREoOENCY 1---....:..~..:...--~-...;__..;._ __

-+---'-----'"-~---=---'-'-----.---'--..:.....------'*"'-" -t EX"i. 'ANA~~SIS SAMPLE TYPE xx.w~'Gl!(XX X>i.V"&iNM~xx

  • uN1Ts x~~l!i'.M(XX XXNV){ff'&xx -X~:tUtxx uNITs 00400 1 0 I

I EFFLUENT GROSS 00400 7 0 INTAKE FROM STREAM FLDWr IN.CONDUIT OR THRU TREAT~ENT PLAN 50050 1 0 EFFLUENT GROSS VALU-\\

HLORINE, TOTAL RESIDUAL 50060 R 1 SEE COMMENTS BELOW CHLORINE, TOTAL RESIDUAL 50060 s 1 SEE COMT"1ENTS.BELOW CHLORINE, TOTAL RESIDUAL 50060 T 1.

SEE COMMENTS BELOW

c. Vondra.

G.M.- Salem Ops.

TYPED OR PRINTED

~~J\\~e~xPSWrJBN f.'Ot!A'Ym~slf~re~ 'SWSc"'D'SciJS (NO CWS FLOW)

ENTER GNODIN FOR LOCATIONS THAT DO NOT APPLY*

WHEN MAIN CONDENSERS ARE CHLORINATED, MONITOR TRC 3 TIMES EPA*Form 3320*1 (Rev. 9-88) Previous editions may be used.

Yl;:AR MO DAY

= SWS DSCHG (NORMAL C~ND) "T" = CWS DSCHG PER WEEK DURING 2-HR PERIODS OF CHLORINATION*

P'AGE 10 OP' 11

PERMITTEE NAME/ADDRESS {Include

~ac~~ Name/Locaffs ~'g!{!rent)

,!!l\\M.! _________________

AD~m:n_~* O!..._BOLJ3~2L ______ _

J:!ANCOCKLBRIDGE~o.!_0803lL_ __

NATIONAL POLLUTANT DISCHAltGIE !ELIMINATION SVSTIEM {NPDESJ DISCHARGE MONITORING REPOJIT (DMRJ 2-16 17*19 NJ0005622 487A 1--------l PERMIT NUMllElt

...------------,....------.. STDRfil H20 t---~--r---.--.--.-~'--r-------..-~*AAJOR SOuTHERN Form Approved.

OMB No. 2040-0004.

Approval expires 6-30-91.

DSCHG. DSN487.*

'SALEM REGION i

~,..

~..

NOTE: Read instructioni..,;,fore c~mpfotinii'this to'rhi *.

mYGEN DEMAND, CHEM*

(HIGH LEVEL) {COD) 0340 l 1 EFFLUENT GROSS XYGEN DEHANDt CHEM*

(HIGH LEVEL) (COD) 0340 2 1

-FFLUENT NET VALUE OXYGEN DEMAND, CHEM*

(HIGH LEVEL) (°COD) 00340 7 1 INTAKE FROM STREAM H

00£t.00 1 1

EFFLUENT GROSS VALU OLIDS, TOTAL US PENDED 00530 1 1 EFFLUENT GROSS SOLIDS, TOTAL SUSPENDED 00530 2 1 EFFLUENT NET VALUE SOLIDS,. TOTAL SUSPENDED 00530 7 1 INTAKE FROK STREAM~ fu NAME/TITLE PRINCIPAL EXECUTIVE OFFICER

c. Vondra G.M. -

Salem Ops~*

TYPED OR PRINTED I. CERTIFY UNDER PENAi--TY* OF LAW THAT I HAVE PERSONALLY' EXAMINEo::.l AND AM FAMILIAR WITH THE INFORMATION SUBMITTED HEREIN: ANO.'BASED'*~

ON MY. INQUIRY.OF THOSE ll!IDIVIOUALS IMMEDIATELY RESPON.SIBLE FOR':.:0 OBTAINING THE.. INFORMATIO;-j,' I BELIEVE THE SUBMITTED INFORMATION*"'

IS TRUE. ACCUR 0

ATE ANO COMPLETE. I AM AWARE THAT. THERE ARE SIG*"'

NIFICANT PENAL"f'.IES FOR SUBMITTING... FALSE INFORMATION.. INCLUDlr-iG: *. ;h~"(f.~~~~~?l~~~~=---1 THE POSSIBILITY OF' FINE ANO *IMPRISONMENT. SEE IB U.S.C

§ 1001 AND" 33 USC§ 1319. fPt'na/tin undt>r thf'lff' statult'H ma.v for/utlf' f,'nt'11 up Ill 11'1.IHHI and 11r ma.rimum impri11r111nlf'lll 11( ht'IU't't'n fi month11 and,;.w*ar11.I COMMENT AND EXPLANATION OF ANY VIOLATIONS (Reference"" ullaclrments here)

EPA*Form 3320*1 (Rev. 9*88) Previous editions may be used.

,,
NUMBER.

.YEAR*

MO SAMPLE TYPE DAY PAGIE 11 Of' 17

PERMITTEE NAMIE/ADDRIESS (lnc/11de Facilily Name/Location If different)

~--__e_~.&G _* -------------------------

ADDR!!! _

_f_* 0 !........~!UL.23Q..lN2:l_ ____________ _


~M~qLBRIDGE~L0603L __ _

NATIONAL POLLUTANT DISCHAftQI: l:LIMINATIOlf SYSTEM (NPDESJ DISCHARGE MONITORING REPORT tDMRJ 2-16 17-19 N..10005622 467A l-""-------1 PERMIT NUMBER DISCHARGE NUM*ER STCJRM H20 MAJOR SOUTHERN Form Approved.

OMB No. 2040-0004.

Approval expires 6-30-91.

DSCHG* DSN487 S~LEf'\\

REGION.

FACIL.1~_*1SE&G5ALEM~NERATIN~STATIO~

L.OCATIO~_Lfil!!~...ALLOWA YLCREEt.N-!_080 3L_

DMR NUMBER: 92120268 NOTE: Read instructio~~ ~f~~e *i:oiriplethtirthis to.rm.

PARAMETER (32-37)

YDROCARBONS,IN H20, IR?CC14 EXT* CHROMA 00551 1 1 FFLUENT GROSS VALUE YDROCARBDNS;IN.H20, IR,CC14 EXT* CHROMA 00551 2 1 EFFLUENT NET VALUE HYDROCARBONS,IN.H20t IRrCC14 EXT* CHROMA 00551 1 1 INTAKE FROM STREAM FLOW~ IN CONDUIT OR HRU TREATMENT~PLAN I 50050 1 1 EFFLUENT GROSS ~ALU

c. Vondra G.M.- Sal¢m Ops.

TYPED OR PRINTED (3 Card Only)

QUANTITY OR LOADING (4 Card Omy)

QUALITY OR CONCENTRATION (46-53)

(54-61)

(38-45).

(46-$3y

($4-61)

NO. FRE~:NCY 1--------'----r-----'-----,--..---+--'----'---.----'----:-----r_,_----"'------,.----'-'--t EX*

ANALYSIS SAMPLE TYPE XYM~'tti'(XX X)#4Xt'>.fl1'.~xx uN1Ts

  • -x~~)Ut~xx.x~MM~xx *.X~~xx I CERTIFY UNDER PENALT.Y OF LAW THAT* I HAVE PERSONALLY EXAMINED:

AND AM FAMILIAR WITH THE INFORMATION. SUBMITTED HEREIN:.AND BASED*.

ON MY INQUIRY OF :.THOSE INDIViDUALS IMMEDIATELY RESPONSIBLE :FoR:

OBTAINING.THE INFORMATION.

I *BELIEVE. THE**.suBMITTED INFORMATION IS TRUE. ACCURATE AND *COMPLETE. *1 AM AWARE **THAT THERE ARE;:SIG*

NIFICANT PENALTIES FOR SUBMITTING FALSE INf"ORMATION,* INCLUDING THE POSSIBILITY OF FINE. AND IMPRISONMENT SEE IB U.S.C I 1001 AND*:

33 use§ 1319. fPt'nalti<'H undt'r the11f' 1tatutt'H ma.v inrludr fin"" up to lltJ,fHHI a1&d ur maximum impri:w11mn1t of hf'llA*f'f'n 6 mtJnlhll and S,\\'Par11.J OFFIC::.ER OR AUT!:fORIZED.AGENT 01 2.~

. NU.MBER YEAR MO DAY COMMENT AND EXPLANATION OF ANY VIOLATIONS (Reference 11/1 utl<lchments here)

EPA*Form 3320*1 (Rev. 9*88) Prsvlous editions may be used.

(~!!:PLACES l!:f'A iroRM T-*o WHICH MAY NOT *11: UHD,J /; "?> ;i...,

I"\\ g' 16".3 I D. RS:


----.-.- ----~ ~------ -----

f'AGIE

.1 ?

01" l 7

NATIONAL. l'OL.L.UTANT DISCHAllOll llL.IMINATION lllYSTllM (NPDESJ l'ERMITTEE NAMll/ADDIUESS (Include Faclllty Name/Location If dllfc,cnt)

~--_f_SE&G ____________ _

DISCHARGE MONITORING RE:PORT fDMRJ 2-16 17-19 Form Approved.

OMBNo. 2040-0004.

ADDftEn _

_f_*O'!...,_B0~23~N2~-------

tU0005622 489A 1---------1

. Approval expires 6-30~91.

____..1:!ANCOCKL:BRIDG:Et.N_.J_08038 ____ _

PERMIT NUMR!iR '-

STORHWATER; MAJOR PARAMETER (32-37)

XYGEN DEMAND, CHEM*

(HIGH LEVEL) (COD) 00340 1 1 FFLUENT GROSS XYGEN DEMAND, CHEM~

(HIGH LEVEL) (COD}.

00340 2 1 EFFLUENT NET VALUE OXYGEN DEMANDr-CHEM*

(HIGH l,..EVEL). (COD) 00340 7 1 INTAKE FROM STREAM PH 00400 1 l EFFLUENT GROSS VALU SOLIDS, TOTAL SUSPENDED 00530.1 1*

EFFLUENT GROSS VALU SOLIDS, TOTAL SUSPENDED 00530 2 1 EFFLUENT NET VALUE SOLIDSj TOTAL SUSPENDED 00530 1 1 INTAKE FROM STREAM

c. Vondra G.M.- Salem Ops.

TYPED OR_ PRINTED SALEM SOUTHERN REGION NOTE: Read instruction~ befot_e co~pleth;g this to"rm.

(3 Ca'd Only)

QUANTITY OR LOADING (4 Card OnJy)'"--

QUALITY OR CONCENTRATION it (46-53)

(54-61)

(38-45)

(46-53):-

(~l)

NO *. FR ~:NCY SAMPLE l----'-....:..'--'---~~...-~-'-~_:__~~-,---~-+-.,.-:....--"i'----~---=----'--:-~--,-'--~---=-----,.----,---1 ~x ANAL.Ys1s TYPE

  • -.-:xw~~xx x~~u~>~>~ uN1Ts XY.Mi~~xx x~~xx
x~l!UXXX uN1Ts I CERTIFY UNDER PENALTY OF LAW THAT I HAVE PERSONALLY EXAMINED.

AND AM FAMILIAR WITH THE llllFORMATION SUBMITTED HEREIN: AND !IASED ON MY INQUIRY OF THOSE INDIVIDUALS IMMEOIATEL Y RESPONSIBCE FOR OBTAINING THE INFORMATION.

I BELIEVE. THE SUBMITTED llllFORMATION**

IS TRUE. ACCURATE AND COMPLETE. I AM AWARE THAT THERE ARE SIG:

NIFICANT PENALTIES FOR SUBMITTING FALSE INFOF;MATION.

INCLUDING THE POSSIBIL:ITY OF FINE AND IMPRISONMENT SEE lB U.S.C i 1001 AND*

33 us.c § 1319. rPenaltie.'i uruit'r thl'Nf' 5tatutt'S nia:v inrludf' lint's up to IW.tHHJ a11.d or ma.rim um inipri~wnmnlt uf hf'tu*f"f'n 6 months and,:;.\\*rar11.1 OFFICER OR AUTHORIZED.. AGENT 01 2.5"

._:~UMBER_

YEAR.

MO DAY COMMENT AND EXPLANATION OF ANY VIOLATIONS (Ref.,ence t11l ut/C/d1ments here)

EPA*Form 3320*1 (Rev. 9-88) Previous editions may be used.

l'AGE 1 ~ 01' 17

PARAMETER (32-37)

YOROC ARBO NS, IN H20, SAMPLE R 'cc 14 EXT. CHROHAT MEASUREMENT 0551 1 1 FFLLIENT GROSS VALUE YDROCARBONS, IN H20t SAMPLE R rCC14 EXT* CHROMAT MEAsuREMENT 0551 2 1 EFfLUENT.NET*VALUE YDROCARBONS,IN H20~

IR,CC14 EXT* C~kOMA 00551 ?

l '-'

INTAKE FROM STREAfl FLOW, IN CONDUIT OR HRU TREATMENT 'PLAN 50050 1 1 EFFLUENT GROSS VALU

c. Vondra G. M. -

Salem Ops.*

TYPED OR PRINTED NATIONAL "0LLUTANT DISCHA"GIE ELIMINATION SYSTIEM (NPDESJ DISCHARGE MONITORING REPORT (DMRJ 2~6 1~9 fU0005622 489~

PERMIT NUMllER *.

Form Approved.

OMB No. 2040-0004.

  • ~

1 *-* ** Apprcivarex.pires 6-3d-9t.

STOR.. WATERi HAJbR.

~-: ~ALEM SOti;rHERN.. REG.IO,.... ::;

NOTE: Read inltruction~

7~fO~e ~ompl~tilig1his to'rm.

)..- -..

(3 Card Only)

QUANTITY OR LOADING (4 Card Only)

QUALITY.OR CONCENTRATION (46-53)

(54-61)

(38-45)

(46-S3)*..

(54-61)

NO. FRE~~NCY SAMPLE 1----'----'---~--'---'---~----l---'-------'--~---=--.;....:.----,---"--..:.----.-----i E_X ANALYSIS TYPE XY~~IKXX xx.v~"Mm:+:xx uN1Ts X~!Q!~XX x~~~xx. xx.~x.ilOii¥.0X uNl'rs_

1 1

!'!UMBER

.. YEAR MO DAY COMMENT AND EXPl.ANATION Of' ANY VIOl.ATIONS (Reference t1// 111/11chments here)

EPA*form 3320-1 (Rev. 9-88) Provious editions may be used..

"AGE 14 Of' J 7

PERMITTEE NAME/ADDRE!IS (Include Facility Name/location if different}

NATIONAL POLLUTANT DISCHA"GI: l:LIMINATION SVSTl:M (NPDESJ DISCHARGE MONITORING RE:PORT fDMRJ

~

__ _e_s..f_~-------------

ADDll~_.....e..tl:J.~fill!_~qf_N2l....:._ ______ _


~~ro~L~U~~L0803L __ _

FAclL.!.!:! _

_f_S E~G 2_ALEH.:jiENERATJ:NG_ST*AT:IOL LOCA~~_J,.JJ..klEB.__ALLOWAY~CREErll-L_OS03L_'_

DMR NUMBER: 92120268 PARAMETER (32-37)

EHPERATURE? *WATER EG

  • CENTI GRADE 0010.l 0 FFLUENT GROSS VALUE?

XYGEN DEMAND, CHEM~

(HIGH LEVEL} (COD) 0340 1 0 EFFLUENT GROSS PH 00400 1 0 EFFLUENT GROSS VALU SOLIDSy TOTAL SUSPENDED 00530,1 0 EFFLUENT GROSS VALUEh

, YDROCARBONS,IN'H20t IR,CC14 EXT. £HROHA 00551 1 0 EFFLUENT GROSS VALU-FLOW, IN CONDUIT OR:

HRU TREATMENT 50050 1 0

~Ff-LUENT GROSS VALU 2-i6 17-19 NJ0005622 1-8....::.7..;...;B.;;...;.A __

PERMIT NUMlllEll*** *"

'---'-'---'"-------"-..:.:J...

1. CERTIFY UNDER PENALTY OF LAW THAT:* 1 Hl\\.VE *PERSO.NALLX EXAMINED.

AND AM FAMILIAR WITH THE'.INFORMATION SUBMITTED HEREIN:. AND BASED*

ON MY INQUIRY* OF ::THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR" OBTAINING THE' INFORMATION.

I BELIEVE THE SUBMITTED INFORMATION.

Form Approved.

OMB No. 2040-0004.

  • -- ***
  • Approval expires s-30:.gi.

o3+~sKIH T~NK-~~N.~:~lB.. I.NJ PERMIT*.:~

MAJOR

~ *.* *. ::o. SALEM SOUTHERN REG.Ia°N :*: :=~*. *;: :: :

NOTE: Read inttructioni

  • b;;t6~e ~~omph!tl_i;g this tdrm.

SAMPLE TYPE (69-70)

c. Vondra G.M.- Salem Ops.

IS TRUE. ACCURATE "AND COMPLETE.. I AM AWARE' THAT. THERE ARE*SIG; 11;~~~"2~~~~~~f:_ ___ j NIFICANT PENA"Li'IES *.FOR SUBMITTING FALSE. INFORMATION.". INCLUOlNG 1j THE POSSIBILITY* OF FINE AND IMPRISONMENT. SEE 18 U.S.C I 1001 AND 33 U 5 C § 1 319. IPl'naltic*s undt>r tht~f' &tatutt's ma,v inrludf' f,'nt'lf up to 1111,(HltJ a,,id ur maximum inrpritmnmt'llt t1{ ht'IU*t'f'n 6 month~ and.l,\\'f'ar.'l.J 01 2..S-TYPED OR PRINTED OFFIC.ER OR AUTHORIZEC? AGENT NUMBER Y~AR MO DAY

  • COMMENT AND EXPLANATION OF ANY VIOLATIONS (Reference"" uttuchmenls here)

EPA-Form 3320*1 (Rev. 9*88) Previous editions may be used.

PAGE J 'j oir 17

P'ERMITTEE HAME/ADDIUlSS (Include Facllity Name/location I/different)

NATIONAL P'OLLUTANT DISCHAltGI: ELIMINATION SYSTEM (NPDESJ

~--_f_SES.G ____________ _

DISCHARGE MONITORING REPORT fDMRJ 2*l6 17-19 Form Approved.

AD~~-_f_!J!.~B0~3~N21 _______ _

N~OQ05622 89AA 1---------1 OMB No. 2040-0004.

ApprovaJexpires S.:30-91.

____.J:!.A NCOCKLBRIDGEtN_J_0803f!_ __ _

PERMIT NUMlillS:R "Dl9CHAltGE NUM*IER PARAMETER (32-37)

OXYGEN DEMANDt CHEM*

(HIGH LEVEL) {COD) 00340 1 0 EFFLUENT GROSS VALU PH 00400 1 0 EFFLUENT GROSS YALU SOLIDS, TOTAL SUSPENDED 00530" 1 0.

EFFLUENT GROSS YALU YDROCARBONS1IN*.H201 R,CC14 EXT* CHROMA 0055). 1 0

EFFLUENT GROSS VALU FLOW, IN CONDUIT OR THRU TREATMENT PLAN 50050 l'O EFFLUENT GROSS VALU MONITORING PERIOD

~1:SKIM P'IAJOR TANK-DSN489A IN PERMIT SALEM SOUTHERN REG.ION NOTE: Read instructioni before completihgthis fOrm..

(3 Card Only)

QUANTITY OR LOADING (4 Card Only) :

QUALITY OR CONCE:NTRATION (46-53)

(54-M)

(38-45)

(46-53).

(54-61)

NO. FRE~FENCY SAMPLE 1-----'---";;...:..--"""'T'"-----'"-'---'---..-----+--"'--"-'---.-----'---'----r---~--"-----,.-----; EX ANALYSIS TYPE XXAN:IUMa~XX XX*:E'.R'~~XX X~~M~XX 62-63)

(64-68)

(69-70)

UNITS NODI NODI 0

. i' CERTIFY UNDER PEFl"!'LTY OF LAW THAT *1 HAVE !"ERSONALLY EXAMINED:'

1-----------------------1 AND AM FAMILIAR WITH THE INFORMATION *SUBMITTED HEREIN;.AND BASED:

ON MY INQUIRY~ OF *~THOSE INDIVIDUALS IMMEQIATEL Y RESPONSIBLE :Fo*='

OBTAINING THE. INFORMATION.

I BELIEVE* THE*; SlJBMITTED INFORMATION.:

c. Vondra G.M.- Salem Ops.

~Fl~~~~ AP~~~~~~~ "~6'~ c~~~~

.. ~ A~AL~~~~~;b~~T~Ti~~~EIN~~~&~~!. h/':.A~~~r.li~~u~~::_=-=----1 THE POSSIBILITY OF FINE AND. IMPRISONMENT. SEE "18 U.S.C

§ 1001 AND~

33 USC§ 1319. fPenalti*" ufllit'r thf'~f' stalult'N ma,v inrludr (int'H up tu $/fl,(HHI TYPED OR PRINTED a1ul "'maximum inrpri1umnw11t of h1*tu*t't'n 6 munthN and,;,\\'f'Ortc.I

~FFICER OR AUTHORIZED AGENT COMMENT AND EXPLANATION OF ANY VIOLATIONS (llefer<*nce t1// t1/lt1chments here)

EPA*Form 3320-1 (Rev. 9-88) Prsvious editions may be used.

01 2.~

NUMBER YEAR MO DAY l'AGE l "' 01' l 7

PARAMETER (32-37)

XYGEN DEMAND, CHEM*

(HIGH LEVEL) (COD) 0340 1 0 GROSS Qt~OO 1 0 EFFLUENT GROSS VALU SOLIDS,. TOTAL SUSPENDED 0530 1 0 EFFLUENT GROSS VALUE.

YDROCi,RBONS,IN **ttzo, IR1CC14 EXT* CHROMA 00551 1 0 EFFLUENT GROSS VALU FLOW, IN CONDUIT OR HRU TREATMENT PLANT 50050 1 0 EFFLUENT GROSS

c. Vondra G.M.- Salem Ops*

TYPED OR PRINTED NATIONAL P'OLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDESJ DISCHARGE MONITORING REPORT (DMRJ

~~

l~H NJ0005622 89;8A 1----------1 PERMIT NUMBER Form Approved.

OMB No. 2040-0004.

Approval expires 6-30-91.

'~\\.

  1. 2: SKI~ TANK-DSN't89B.IN PERMIT,. *;i MAJOR
  • . '.. ::. S'ALEM T

SOUTHERN REGJ:ON N\\'.?TE: Read instructionibefore ~o~pletittg'this to'rm.

I CERTIFY UNDER PENALTY* OF LAW. THAT"I HAVE PERSONALLY.-EXAMINED..

AND AM FAMILIAR WITH THE INFORt-~ATION SUBMITTED HEREIN; AND*::BASED.

ON MY INQUIRY OF THOSE INDIVIDUALS IMMEDIATELY RESPONSIBLE FOR('.-

QUALITY OR CONCENTRATION

( 46-53)

(:SUJ)

BTTA~~~G Ac!ci-
;RA~:o:~;T~Oo'!1p~~f.L11E'i1i.. :~A~~u~~~f-~H~~~

0

~EAT~~;*

6 0 9 NIFICANT PENALTIES ;FOR. SUBMITTING FALSE *.. INFORMAT.ION..'INCLUDING.. ~'(A~'Jl.'IJ~~~~~~------1 THE POSSIBILITY OF FINE AND IMPRISONMENT. SEE 18 U.S.C

§--1001 AND**

33 USC § 1319, fPf'nalti<'.'l undt>r the.'lf' statutn; ma,v inr/udp fint'H up to SlflJJ(HI a rad ur maximum imprisminw11t of h1*tu*t'f'n 6 months and,;,\\'f'Or.... J UNITS No FREQUENCY OF EX. ANALYSIS (64'-68)

SAMPLE TYPE (69-70)

COMMENT AND EXPLANATION OF ANY VIOLATIONS (Refer<*nce all a11ad1ments here)

EPA*Form 3320*1 (Rev. 9-88) Provious editions may be used.

P'AGE 17 Of" 17