ML18095A909

From kanterella
Jump to navigation Jump to search
Confirms That 10 Anchor-Darling Model S350W Swing Check Valves Installed in Facility,Per NRC Bulletin 89-002.All Anchor-Darling Studs Replaced W/Upgraded Matl
ML18095A909
Person / Time
Site: Salem PSEG icon.png
Issue date: 05/08/1991
From: Labruna S
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
IEB-89-002, IEB-89-2, NLR-N91061, NUDOCS 9105150247
Download: ML18095A909 (2)


Text

Public Service Electric and Gas Company Stanley LaBruna Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-4800 MAY 0 8 1991 NLR-N91061 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

CONFIRMATORY LETTER BULLETIN 89-02 SALEM GENERATING STATION UNIT NO. 1 DOCKET NO. 50-272 Public Service Electric & Gas Company (PSE&G) has performed a review of our engineering documentation regarding types and composition of swing check valves in use at Salem Generating Station, Unit No. 1 in accordance with Bulletin 89-02.

We hereby confirm that Salem Unit No. 1 has ten Anchor-Darling, Model S350W swing check valves.

In addition, eight Velan swing check valves using the same type bolting were identified.

All eighteen valves were inspected during the last two refueling outages to ensure an acceptable stud material was installed.

All Anchor-Darling studs were replaced with upgraded material.

On the Velan valves, any retaining block stud that was unacceptable was replaced with an upgraded material.

No cracks were noted on any of the studs.

A summary of our research is available on site for your review.

Should there be any questions with regard to this submittal, please do not hesitate to contact us.

9105150247 910508 PDR ADOCK 05000272 Q

PDR Sincerely, J:'GJa e I C1

Document Control Desk NLR-N91061 C

Mr. J. C. Stone Licensing Project Manager Mr. T. Johnson Senior Resident Inspector 2

Mr. T. Martin, Administrator Region I Mr. Kent Tosch, Chief New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625