ML18095A796

From kanterella
Jump to navigation Jump to search
SMR DC RAI - Request for Additional Information No. 408 Erai No. 9325 (15.00.02)
ML18095A796
Person / Time
Site: NuScale
Issue date: 04/05/2018
From:
NRC
To:
NRC/NRO/DNRL/LB1
References
Download: ML18095A796 (4)


Text

1 NuScaleDCRaisPEm Resource From:

Chowdhury, Prosanta Sent:

Thursday, April 5, 2018 2:28 PM To:

Request for Additional Information Cc:

Lee, Samuel; Cranston, Gregory; Franovich, Rani; Karas, Rebecca; Thurston, Carl; NuScaleDCRaisPEm Resource

Subject:

Request for Additional Information No. 408 eRAI No. 9325 (15.00.02)

Attachments:

Request for Additional Information No. 408 (eRAI No. 9325).pdf Attached please find NRC staffs request for additional information (RAI) concerning review of the NuScale Design Certification Application.

The NRC Staff recognizes that NuScale has preliminarily identified that the response to one or more questions in this RAI is likely to require greater than 60 days. NuScale is expected to provide a schedule for the RAI response by email within 14 days.

If you have any questions, please contact me.

Thank you.

Prosanta Chowdhury, Project Manager Licensing Branch 1 (NuScale)

Division of New Reactor Licensing Office of New Reactors U.S. Nuclear Regulatory Commission 301-415-1647

Hearing Identifier:

NuScale_SMR_DC_RAI_Public Email Number:

439 Mail Envelope Properties (BN7PR09MB260988AE6E502AFFD357C2E19EBB0)

Subject:

Request for Additional Information No. 408 eRAI No. 9325 (15.00.02)

Sent Date:

4/5/2018 2:27:40 PM Received Date:

4/5/2018 2:27:44 PM From:

Chowdhury, Prosanta Created By:

Prosanta.Chowdhury@nrc.gov Recipients:

"Lee, Samuel" <Samuel.Lee@nrc.gov>

Tracking Status: None "Cranston, Gregory" <Gregory.Cranston@nrc.gov>

Tracking Status: None "Franovich, Rani" <Rani.Franovich@nrc.gov>

Tracking Status: None "Karas, Rebecca" <Rebecca.Karas@nrc.gov>

Tracking Status: None "Thurston, Carl" <Carl.Thurston@nrc.gov>

Tracking Status: None "NuScaleDCRaisPEm Resource" <NuScaleDCRaisPEm.Resource@nrc.gov>

Tracking Status: None "Request for Additional Information" <RAI@nuscalepower.com>

Tracking Status: None Post Office:

BN7PR09MB2609.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 675 4/5/2018 2:27:44 PM Request for Additional Information No. 408 (eRAI No. 9325).pdf 77166 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

Request for Additional Information No. 408 (eRAI No. 9325)

Issue Date: 04/05/2018 Application

Title:

NuScale Standard Design Certification 048 Operating Company: NuScale Power, LLC Docket No.52-048 Review Section: 15.00.02 - Review of Transient and Accident Analysis Methods 01/2006 Application Section:

QUESTIONS 15.00.02-1 Title 10 of the Code of Federal Regulations (10 CFR) Part 52, Section 47 (a)(2) states, A description and analysis of the structures, systems, and components (SSCs) of the facility, with emphasis upon performance requirements, the bases, with technical justification therefor, upon which these requirements have been established, and the evaluations required to show that safety functions will be accomplished. Likewise, 10 CFR Part 50, Appendix K, II.4 - Required Documentation, requires that, To the extent practicable, predictions of the evaluation model, or portions thereof, shall be compared with applicable experimental information. Additionally, GDC-10 Reactor design states the reactor core and associated coolant, control, and protection systems shall be designed with appropriate margin to assure that specified acceptable fuel design limits are not exceeded during any condition of normal operation, including the effects of anticipated operational occurrences.

As stated in RG 1.203, an evaluation model (EM) is the calculational framework for evaluating the behavior of the reactor system during a postulated transient or design-basis accident. As such, the EM may include one or more computer programs, special models, and all other information needed to apply the calculational framework to a specific event, as illustrated by the following examples:

1) Procedures for treating the input and output information (particularly the code input arising from the plant geometry and the assumed plant state at transient initiation).
2) Specification of those portions of the analysis not included in the computer programs for which alternative approaches are used.
3) All other information needed to specify the calculational procedure.

The entirety of an EM ultimately determines whether the results are in compliance with applicable regulations. Therefore, the development, assessment, and review processes must consider the entire EM.

NRELAP5 code and input models used are key components of FSAR 15.0.2 "Review of Transient and Accident Analyses" results. The staff noted that NRELAP5 models that support the Chapter 15 accident analysis (including NRELAP5 analyses for FSAR Chapters 15.1.1 through 15.6.6) are built from a base model, EC-A010-1782 "NuScale NRELAP5 Module Basemodel," rev. 0, that did not address a large number of small changes in NuScale Power Module (NPM) geometry as contained in EC-A010-1507, rev 3 Transient Model Input Parameters. It apears that the base model, EC-A010-1782, was built from EC-A010-1507, rev

0. NRC staff understands that the NuScale engineering change notice (ECNs) are designed to account for each NRELAP5 model document modification needed as changes or errors are identified that affect that documents inputs or results, however, it appears to NRC staff that many document changes are without ECNs. NRC staff is trying to understand (1) how the applicant plans to reconcile the changes made in the NPM design to the NRELAP5 analyses for FSAR Chapters 15.1.1 through 15.6.6 and (2) how NRC staff can determine that the analysis model results remain valid such that margins are understood and protected.

Please provide a description of all NRELAP5 analyses that support FSAR Chapters 6 and 15 and confirm that the geometry inputs used and results obtained include adequate margin per applicable requirements of GDC-10 and 10 CFR 52.47. Additionally, please provide a list of changes in NPM geometry, or other design changes, since EC-A010-1507, rev. 0 (which is bases of EC-A010-1782) to current Rev. 3 (including any later updates) so staff can better understand the design changes made.