ML18095A195

From kanterella
Jump to navigation Jump to search
Informs of Plans to Revise Rept NFU-0039,Rev 1 to Address Reactor Physics Core Modeling Methods Only.Rept Will Also Reflect 18-month Cycle Experience
ML18095A195
Person / Time
Site: Salem  
Issue date: 05/09/1990
From: Crimmins T
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NLR-N90064, NUDOCS 9005160112
Download: ML18095A195 (3)


Text

  • '

Public Service Electric and Gas Company Thomas M. Crimmins, Jr.

Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-4700 Vice President - Nuclear Engineering MAY 0 9 19901 NLR-N90064 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

SALEM REACTOR PHYSICS METHODS REVISION OF NFU-0039, REVISION 1 SALEM UNIT NOS. 1 AND 2 DOCKET NOS. 50-272 AND 50-311 On January 20, 1986, Public Service Electric and Gas (PSE&G) submitted the report, "Salem Reactor Physics Methods, Volume 1, Model Qualification" (NFU-0039), to the NRC.

Brookhaven National Laboratory (BNL) was assigned as the reviewer by the NRC.

on June 19, 1986, BNL transmitted to PSE&G a core analysis standard problem.

The analysis by PSE&G on March 9, 1987, and the evaluation of these computations by BNL on June 24, 1987, served as the NRC's review of sections 1.0 to 3.0 of the report.

This review determined that PSE&G's methodology for analyzing core performance was acceptable.

On March 3, 1987, BNL completed its initial review of "Salem Reactor Physics Methods, Sections 4.0 and 5.0 concerning Reload Safety Evaluations (RSE).

However, these sections were not approved at that time and the report was held for further revision.

Due to reorganizational issues within PSE&G, the NRC agreed to put the overall review process on hold, (Reference 1)

  • In July of 1989, revision of NFU-0039 (Revision 1) was resumed by PSE&G.

In order to facilitate the completion of NRC review, PSE&G plans to revise the current report to address only the reactor physics core modeling methods and associated reliability factors.

This report will also reflect recent 18-month cycle experience.

The RSE methods sections will be deleted and re~ubmitted as a separate report for NRC review and approval.

Document Control Desk NLR-N90064 2

MAY o g 1onn The tentative schedule for these submittals and the desired NRC approval dates are as follows:

1.

PSE&G Submittal of NFU-0039, Revision 2 12/30/90

2.

NRC Approval of NFU-0039, Revision 2 6/30/91

3.

PSE&G Submittal of RSE Methods Report 10/01/91

4.

NRC Approval of RSE Methods Report 10/01/92 (In support of Salem 2 Cycle 8 Reload)

Should you have any questions regarding this information, please contact us.

C Mr. J. c. Stone Licensing Project Manager Mr. T. Johnson Senior Resident Inspector Mr. T. Martin, Administrator Region 1 Mr. Kent Tosch, Chief Sincerely, qL/uc~7 New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625

Document Control Desk NLR-N90064

REFERENCES:

3

1.

Telephone conversation, E. s. Rosenfeld (PSE&G) and M. Dunenfeld (NRC), October of 1986.

2.

Letter, Herbert N. Berkow (NRC) to Corbin A. McNeil, Jr.

(PSE&G) "Report Entitled 'Salem Reactor Physics Methods, Volume 1 Model Qualification'", Dated March 12, 1986.

MAY O 9 1990

3.

Letter, J. F. Carew (BNL) to E. S. Rosenfeld (PSE&G), "PWR Core Analysis Standard Problem", dated June 19, 1986.

4.

Letter, E. s. Rosenfeld (PSE&G) to J. F. Carew (BNL),

"Transmittal of PSE&G Analysis of the Core Analysis Standard Problem", dated March 9, 1987.

5.

Letter, J. F. Carew (BNL) to Marvin Dunenfeld (NRC), "PSE&G Calculation of the BNL Core Analysis Standard Problem",

dated June 24, 1987.

6.

Letter, Partha Neogy (BNL) to Marvin Dunenfeld (NRC), "Salem Reactor Physics Methods (NFU-0039, Revision 1, March 14, 1986), dated on March 3, 1987.