Category:Letter
MONTHYEARML20141L3142020-06-0909 June 2020 MRP-227, Rev 1-A Supplemental Information Final SE Transmittal Email ML19253A0602020-02-24024 February 2020 Proprietary Determination of EPRI Presentation Material for 9/11/19, Closed Mtg to Discuss Plans for Submittal of BWRVIP-315: Vessel and Internals Project, Reactor Internals Aging Management Evaluation for Extended Operations ML19296A0092020-01-15015 January 2020 U.S. Nuclear Regulatory Commission Verification Letter and Proprietary Determination for - BWRVIP-241-A: BWR Vessel and Internals Project, Probabilistic Fracture Mechanics Evaluation for the Boiling Water Reactor Nozzle-To-Vessel ML19296A0102020-01-15015 January 2020 U.S. Nuclear Regulatory Commission Verification Letter and Proprietary Determination for - BWRVIP-108-A: BWR Vessel and Internals Project, Technical Basis for the Reduction of Inspection Requirements for the Boiling Water Reactor ML19296A0112020-01-15015 January 2020 U.S. Nuclear Regulatory Commission Verification Letter and Proprietary Determination for - BWRVIP-41, Revision 4-A: BWR Vessel and Internals Project, BWR Jet Pump Assembly Inspection and Flaw Evaluation Guidelines ML19240A0262019-10-0707 October 2019 Acceptance Review and Proprietary Determination of Electric Power Research Institute Topical Report BWRVIP-329, BWR (Boiling Water Reactor) Vessel and Internals Project, Updated Probalistic Fracture Mechanics Analyses for BWR RPV ML19175A1532019-09-0505 September 2019 Proprietary Determination of Electric Power Research Institute Revised Response to Requests for Additional Information Eseb RAI-1 on BWRVIP-25, Revision 1, Boiling Water Reactor Vessel and Internals Project, BWR Core Plate Inspection and Fl ML19198A0102019-07-23023 July 2019 Approval of Change in the BWRVIP Integrated Surveillance Program Capsule Test Schedule to Accommodate Early Closure ML19171A0022019-07-22022 July 2019 U.S. Nuclear Regulatory Commission Verification Letter and Proprietary Determination for BWRVIP-62-A (2018 Update): BWR Vessel and Internals Project, Technical Basis for Inspection Relief for BWR Internal Components with Hydrogen Injection, ML19196A1072019-07-11011 July 2019 EPRI - Request for Permission to Dispose of Reconstituted Surveillance Specimens from the Columbia Generating Station Reactor Vessel ML19100A0022019-04-25025 April 2019 Acceptance Review for Electric Power Research Institute Topical Report BWRVIP-321: BWR Vessel and Internals Project, Plan for Extension of the Bwr Integrated Surveillance Program (ISP) Through the Second License Renewal (Slr). ML19091A2592019-04-23023 April 2019 Proprietary Determination of Electric Power Research Institute Topical Report BWRVIP-321: BWR Vessel and Internals Project, Plan for Extension of the BWR Integrated Surveillance Program (ISP) Through the Second License Renewal (Slr). (EPID: ML18288A1902018-11-14014 November 2018 Proprietary Determination of Electric Power Research Institute Responses for RAI on BWRVIP-25, Rev. 1, Boiling Water Reactor Vessel and Internals Project, BWR Core Plate Inspection and Flaw Evaluation Guidelines (CAC No. MF8863; EPID L-2016 ML18270A0902018-11-0505 November 2018 Proprietary Determination of Electric Power Research Institute Information for September 26, 2018, Meeting on Subsequent License Renewal ML18269A1192018-09-24024 September 2018 Docket No. 99902016 - September 26, 2018 Meeting with NRC to Discuss Second License Renewal Activities for BWRs ML18243A4832018-08-29029 August 2018 Electric Power Research Institute - Submittal of BWRVIP-319NP: BWR Vessel and Internals Project, Testing and Evaluation of the Hatch Unit 2 120 Degrees Surveillance Capsule ML18142A0192018-07-0606 July 2018 Final SE Related to BWRVIP-62-A, Boiling Water Reactor Vessel and Internals Project, Technical Basis for Inspection Relief for BWR Internal Components with Hydrogen Injection, Use of Online Noble Metal Chemistry in Boiling Water Reactors ML18130A0242018-07-0202 July 2018 Final Nonproprietary Safety Evaluation for BWRVIP-41, Revision 4, BWRVIP Jet Pump Assembly Inspection and Flaw Evaluation Guidelines (NRC-2018-0123;EPID L-2014-TOP-0008) ML18130A0502018-06-26026 June 2018 Transmittal Letter Regarding Final Proprietary Safety Evaluation for Electric Power Research Institute Topical Report BWRVIP-41, Revision 4, BWR Jet Pump Assembly Inspection and Flaw Evaluation Guidelines (CAC No. MF4887; EPID L-2014-TOP-00 ML18107A6072018-05-15015 May 2018 Transmittal Letter Regarding Supplemental SE Related to BWRVIP-62-A, BWRVIP, Technical Basis for Inspection Relief for BWR Internal; Components with Hydrogen Injection Use of Online Noble Metal Chemistry in Boiling Water Reactors ML18095A0122018-05-0101 May 2018 U.S. Nuclear Regulatory Commission Approval and Proprietary Determination Letter for BWRVIP-139, Revision 1-A: BWR Vessel and Internals Project, Steam Dryer Inspection and Flaw Evaluation Guidelines ML17171A3172018-04-20020 April 2018 Transmittal Letter for Draft Safety Evaluation for BWRVIP-41, Revision 4, BWR Jet Pump Assembly Inspection and Flaw Evaluation Guidelines ML17004A2562018-04-16016 April 2018 U.S. Nuclear Regulatory Commission Approval and Proprietary Determination Letter for Electric Power Research Institute BWRVIP-42, Revision 1-A ML18043A0902018-04-0909 April 2018 U.S. Nuclear Regulatory Commission Approval and Proprietary Determination Letter for BWRVIP-234-A: BWR Vessel and Internals Project, Thermal Aging and Neutron Embrittlement of Cast Austenitic Stainless Steels for BWR Internals ML18023A4382018-04-0202 April 2018 U.S. Nuclear Regulatory Commission Approval and Proprietary Determination Letter for BWRVIP-183-A Report, BWR Vessel and Internals Project - Top Guide Grid Beam Inspection and Flaw Evaluation Guidelines ML18029A0022018-02-13013 February 2018 Proprietary Determination of Electric Power Research Institute Topical Reports MRP-175 and MRP-211 ML18031A0112018-02-13013 February 2018 Proprietary Determination of Electric Power Research Institute Topical Reports Submitted Via October 5, 2017 Letter 2020-06-09
[Table view] Category:Proprietary Information Review
MONTHYEARML20168A0062020-07-0606 July 2020 Transmittal Email BWRVIP-321 RAI Responses Withholding Determination ML20168A0002020-07-0606 July 2020 Withholding Determination for BWRVIP-321 RAI Responses ML19175A1532019-09-0505 September 2019 Proprietary Determination of Electric Power Research Institute Revised Response to Requests for Additional Information Eseb RAI-1 on BWRVIP-25, Revision 1, Boiling Water Reactor Vessel and Internals Project, BWR Core Plate Inspection and Fl ML18288A1902018-11-14014 November 2018 Proprietary Determination of Electric Power Research Institute Responses for RAI on BWRVIP-25, Rev. 1, Boiling Water Reactor Vessel and Internals Project, BWR Core Plate Inspection and Flaw Evaluation Guidelines (CAC No. MF8863; EPID L-2016 ML18270A0902018-11-0505 November 2018 Proprietary Determination of Electric Power Research Institute Information for September 26, 2018, Meeting on Subsequent License Renewal ML18165A2932018-06-28028 June 2018 U.S. Nuclear Regulatory Commission Verification Letter and Proprietary Determination for Errata for BWRVIP-26-A: BWR Vessel and Internals Project, BWR Top Guide Inspection and Flaw Evaluation Guidelines ML18095A0122018-05-0101 May 2018 U.S. Nuclear Regulatory Commission Approval and Proprietary Determination Letter for BWRVIP-139, Revision 1-A: BWR Vessel and Internals Project, Steam Dryer Inspection and Flaw Evaluation Guidelines ML18043A0902018-04-0909 April 2018 U.S. Nuclear Regulatory Commission Approval and Proprietary Determination Letter for BWRVIP-234-A: BWR Vessel and Internals Project, Thermal Aging and Neutron Embrittlement of Cast Austenitic Stainless Steels for BWR Internals ML18031A0112018-02-13013 February 2018 Proprietary Determination of Electric Power Research Institute Topical Reports Submitted Via October 5, 2017 Letter ML18029A0022018-02-13013 February 2018 Proprietary Determination of Electric Power Research Institute Topical Reports MRP-175 and MRP-211 2020-07-06
[Table view] |
Text
May 1, 2018 Mr. Tim Hanley, Chairman ATTN: Debbie Rouse BWR Vessel and Internals Project 1300 West W.T. Harris Boulevard (Building 1)
Charlotte, NC 28262
SUBJECT:
U.S. NUCLEAR REGULATORY COMMISSION APPROVAL AND PROPRIETARY DETERMINATION LETTER FOR BWRVIP-139, Revision 1-A:
BWR VESSEL AND INTERNALS PROJECT, STEAM DRYER INSPECTION AND FLAW EVALUATION GUIDELINES
Dear Mr. Hanley:
By letter dated April 4, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18096A680), the Electric Power Research Institute (EPRI) provided topical report (TR) BWRVIP-139, Revision 1-A: BWR [Boiling Water Reactor] Vessel and Internals Project, Steam Dryer Inspection and Flaw Evaluation Guidelines. Also submitted was an affidavit executed by Neil Wilmshurst, Vice President and Chief Nuclear Officer requesting that the information contained in BWRVIP-139, Revision 1-A be withheld from public disclosure pursuant to Title 10 of the Code of Federal Regulations, Section 2.390 (10 CFR 2.390).
A nonproprietary copy of the document was also provided and added into the NRC Library in ADAMS as Accession No. ML18096A681.
Based on its review of the document, the NRC staff has determined that the report is acceptable to the extent delineated in the NRC staff safety evaluations transmitted by letters dated August 3, 2011, and November 8, 2015 (ADAMS Accession Nos. ML111662165 and ML16180A462). Appendix I of BWRVIP-139, Revision 1-A documents the changes. The revisions to BWRVIP-139, Revision 1-A do not affect the NRCs accepted-for-use status.
With respect to the request for withholding the information in BWRVIP-139, Revision 1-A, EPRI detailed the reasons in its affidavit.
The NRC staff has reviewed your application and the material in accordance with the requirements of 10 CFR 2.390. On the basis of the statements in the affidavit, the NRC staff has determined that the submitted information contains proprietary, commercial information and should be withheld from public disclosure.
Therefore, the version of the submitted information marked as proprietary will be withheld from public disclosure under 10 CFR 2.390(b) (5) and Section 103(b) of the Atomic Energy Act of 1954, as amended.
Withholding from public inspection shall not affect the right, if any, of persons properly and directly concerned to inspect the documents. If the need arises, the agency may send copies of
T. Hanley this information to its consultants working in this area. The NRC staff will, of course, ensure that the consultants have signed the appropriate agreements for handling proprietary information.
If the basis for withholding this information from public inspection should change in the future such that the information could then be made available for public inspection, you should promptly notify the NRC staff.
You also should understand that the NRC staff may have cause to review this determination in the future, for example, if the scope of a Freedom of Information Act request includes your information. In all review situations, if the NRC makes a determination adverse to the above, you will be notified in advance of any public disclosure.
If you have any questions or require any additional information, please feel free to contact the Project Manager, Mr. Joseph J. Holonich, at 301-415-7297 or via electronic mail at Joseph.Holonich@nrc.gov.
Sincerely,
/RA/
Dennis Morey, Chief Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation Docket No. 99902016
ML18095A012; *concurred via e-mail NRR-106 OFFICE DLP/PLPB/PM* DLP/PLPB/LA* DMLR/MPHB/BC* DMLR/MVIB/BC DE/EMIB/BC*
(JTsao for)
NAME JHolonich DHarrison SRuffin DAlley SBailey DATE 04/26/2018 04/24/2018 04/25/2018 04/25/2018 04/25/2018 OFFICE DLP/PLPB/BC NAME DMorey DATE 05/01/2018