SALEM GENERATING STATION TABLE lA-1
- EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JANUARY -
JUNE 1988 UNIT 1 GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES 1st Quarter 2nd Est. Total(!)
Units Quarter Error, %
A. Fission and Activation Gases
- 1. Total release
- 2. Average release rate for period
- 3. Percent of technical specification limit (T.S. 3.ll.2.2(a))
B. Iodines
- 1. Total iodine-131
- 2. Average release rate for eriod
- 3. Percent of technical specification limit (2)
(T.s. 3.ll.2.3(a))
C. Particulates
- 1. Particulate9 with half-lives
> 8 days
- 2. Average release rate for period
- 3. Percent of technical specification limit (2)
(T.S. 3.ll.2.3(a))
- 4. Gross alpha radioactivity D. Tritium
- 1. Total release
- 2. Average release rate for period
- 3. Percent of technical specification limit (2)
(T.S. 3.ll.2.3(a))
Ci 2.30E+02 2.00E+02 uCi/sec. 2.93E+Ol 2.SSE+Ol l.73E-Ol l.57E-01 Ci 4.58E-06 l.09E-04 uCi sec. 5.83E-07 l.39E-05 9.39E-03 6.SOE-03 Ci l.42E-03 2.27E-05 uCi/sec. l.80E-04 2.89E-06 9.39E-03 6.SOE-03 Ci O.OOE+OO Ci 2.39E+02 2.28E+Ol uCi/sec. 3.03E+Ol 2.90E+OO 9.39E-03 6.SOE-03 (1) For batch releases the estimated overall error is within 10%.
(2) Iodine, tritium, and particulates are treated as a group.
-9*-
50 25 25 50