Text
.
Public Service Electric and Gas Company Steven E. Miltenberger Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-4199 Vice President and Chief Nuclear Officer June 14, 1989 NLR-N89113 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:
WITHDRAWAL OF LICENSE CHANGE REQUEST SALEM GENERATING STATION UNIT NO. 1 $0--_;2?d---
DOCKET NO....Ii;!! M A**
On February 9, 1989, Public Service Electric and Gas Company (PSE&G) submitted a license change request (LCR) to amend Appendix A of Facility Operating License No. DPR-70.
This license change would have provided for an alternate steam generator tube sampling method to that described in the Technical Specifications if a large number of degraded or defective steam generator tubes been discovered in Rows 1 and 2 of the Salem Unit 1 steam generators due to the U-bend primary water stress corrosion cracking phenomenon.
During the Salem Unit 1 Eighth Refueling Outage, all the Row 1 tubes in all four steam generators were plugged due to indications of tangential cracking in a five (5) Row 1 tubes.
In addition, ten (10) tubes were plugged due to measured tube wall degradations greater than or equal to 40% and 19 tubes were plugged with tube wall degradation measured between 30% and 40%.
Due to the total number of defective tubes discovered and their locations, increased eddy current sample sizes were based on Technical Specification requirements and the alternate sampling method was not needed.
As such, PSE&G requests that our request for a license change request for the Salem Unit 1 Technical Specifications dated February 9, 1989 be formally withdrawn.
However, this phenomenon may occur in Row 2 tubes and may require resubmittal of this LCR during some future outage.
E:90620(1:3o::::
F'DR ADOCK F'
8906.14 05000252 F'DC I
---**.J){
Document Control Desk NLR-N89113 2
Should you have any questions regarding this request for withdrawal, please do not hesitate to contact us.
c Mr. J. c. Stone Licensing Project Manager Ms. K. Halvey Gibson Senior Resident Inspector Sincerely, Mr. W. T. Russell, Administrator Region I Mr. Kent Tosch, Chief New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 06-14-89