ML18094A300
| ML18094A300 | |
| Person / Time | |
|---|---|
| Site: | Salem, Hope Creek, 05000000 |
| Issue date: | 12/31/1988 |
| From: | Miltenberger S Public Service Enterprise Group |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| NLR-N89057, NUDOCS 8904050245 | |
| Download: ML18094A300 (5) | |
Text
PfRSO~ EXPOSURE ~ONITORING R~P~
FOR EXPOSURE YEAR: 1988 REPORT DATE:
2/02/89 SALEM GENERATING STATION -
UNIT 1 NRC DOCKET NUMBER: 50-272 PUBLIC SERVICE ELECTRIC AND GAS HANCOCKS B~IOGE, NEW JERSEY OB03o TOT AL WHOLE BODY EXPOSURE RANGE (REMS)
NUMBcR OF INDIVIDUALS I "
- j EACH RA.\\IGE NO MEASURABLE EXPOSURE ******************************
lu 9~
MEASURASLE EXPOSUkE LESS THAN 0.100 *****************
1339 0.100 0.249 **************************************
129 o.2su 0.499 **************************************
73 o.5oo 0.749 **************************************
38 0.150 o.~99 **************************************
16 leOOCJ 1.999 **************************************
14 2.000 2.999 **************************************
0 3.000 3.999 **************************************
0 4.000 4.999 **************************************
0 s.ooo 5.999 **************************************
0 beOOG 6.999 **************************************
0 1.000 7.~99 **************************************
0 6.000 a.999 **************************************
0 9.00CJ
- 9. *~ 99............................................
0.,
.lO.OOQ io.99*9 ***************************************** **
0 11.000 11.999 ************************************
0
>= 12.00J ****************************************
0 TOTAL NUMSERS CF INDIVIDUALS REPORTED:
27'Jd THE ABOVE INFORMATION IS sua~ITTEO FOR THE TOTAL NUMBER OF I~OIVIDUALS FCR WHOM PERSuNNEL MO~ITORING ~AS PROVIDEJ JURING THE CALENOE~ YEA~
Salem Unit 1 Total Man-Rem by TLD for 1988 119.149
PERSON-EXPUSURE MONITORING REPOle FOR EXPOSURE YEAR: 1988 REPORT DATE:
2/02/89 SALEM GENERATING STATION -
UNIT 2 NRC DOCKET NUMBER: 50-311 PUBLIC SERVICE ELECTRIC ANO GAS HANCOCKS BRIDGE, NEW JERSEY 08038 TOTAL WHOLE BODY EXPOSURE RANGE (REMS)
NUMBER OF INDIVIDUALS IN EACH RANGE NO MEASURABLE EXPOSURE ******************************
815 MEASURABLE EXPOSURE LESS THAN 0.100 *****************
1350 0.100 Oe249 **************************************
420 0.250 0.499 *******~******************************
243 o.soo Oa749 **************************************
121 0.750 0.999 **************************************
73 i.ooo 1.999 **************************************
39 2.000 2.999 **************************************
3 3.000 3e999 **************************************
0 4.000 4e999 **************************************
0 s.ooo 5.999 **************************************
0 b.000 6.999 **************************************
0 1.000 7.999 **************************************
0 a.ooo 8.999 **************************************
0 9.000 9e999 ********************~~*****************
0 10.000 10.999 ************************************
0 11.000 11.999 ************************************
0
>= 12.000 ****************************************
0 TOTAL NUMdERS OF INDIVIDUALS REPORTED:
3064 THE ABOVE INFORMATION IS SUBMITTED FOR THE TOTAL NUMBER OF INDIVIDUALS FOR WHOM PERSONNEL MONITORING WAS PROVIDED DURING THE CALENDER YEAR Salem Unit 2 Total Man-Rem by TLD for 1988 384.275
PERSON~ EXPOSURE MONITORING REPD~
FOR EXPOSURE YEAR: 1988 REPORT DATE:
2/02/89 HOPE CREEK GENERATING STATION NRC DOCKET NUMBER: 50-354 PUBLIC SERVICE ELECTRIC AND GAS HANCOCKS BRIDGE, NEW JERSEY 08038 TOTAL WHOLE BODY EXPOSURE RANGE <REMS)
NUMBER OF INDIVIDUALS IN EACH RANGE NO MEASURABLE EXPOSURE ******************************
970 MEASURABLE EXPOSURE LESS THAN OelOO *****************
1032 0.100 0.249 **************************************
301 o.2so 0.499 **************************************
245 o.soo o.749 **************************************
83 o.1so 0.999 **************************************
44 1.000 l.~99 **************************************
29 2.000 z.999 **************************************
0 3.000 3.999 **************************************
0 4.000 4.999 **************************************
0 5.000 5.999 **************************************
0 6e000 6.999 **************************************
0 1.000 7.999 **************************************
0 a.ooo 8e999 **************************************
0 9.000 9.999 ***.**,...................... -. *****.***.******.*.**.***
0 10.000 10.999 **************.*********.*.************
0 11.000 11.999 ************************************
0
>= 12.000 ****************************************
0 TOT~L NUMdERS OF INDIVIDUALS REPORTED:
2704 THE ABOVE INFORMATION IS SUBMITTED FOR THE TOTAL NUMeER OF INDIVIDUALS FOR WHOM PERSON~EL MONITORING WAS PROVIDfD OURING THE CALENDER YEAR Hope Creek Total Man-Rem by TLD for 1988 286.792
'\\
Public Service Electric and Gas Company Steven E. Miltenberger Public Service Electric and Gas Company P.O. Box 236. Hancocks Bridge. NJ 08038 609-339-4199 Vice President and Chief Nuclear Officer March 29, 1989 NLR-N89057 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555
.Gentlemen:
PERSONNEL EXPOSURE AND MONITORING REPORT SALEM AND HOPE CREEK GENERATING STATIONS DOCKET NOS. 50-272, 50-311 AND 50-354 Public Service Electric and Gas Company (PSE&G) hereby submits the Annual Personnel Exposure and Monitoring Report in accordance with the requirements of 10CFR20.407.
This report totals the number of individuals in requisite dose ranges separately for each plant.
The information contained in this report was derived from estimated dose information in the Personnel Radiation Exposure Monitoring System (PREMS).
Should you have any questions regarding this submittal, please contact us.
Sincerely, Attachment
Document Control Desk NLR-N89057 C
Mr. J. c. Stone 2
Licensing Project Manager - Salem Ms. K. Halvey Gibson Senior Resident Inspector - Salem Mr. c. Y. Shiraki Licensing Project Manager - -Hope Creek Mr. G. w. Meyer Senior Resident Inspector -
Hope Creek Mr. W. T. Russell, Administrator Region I Mr. Kent Tosch, Chief New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 03-29-89