Forwards WCAP-11955, Analysis of Capsule Z from Pse&G Salem Unit 1 Reactor Vessel Radiation Surveillance Program. Comparison of Test Results for Surveillance Matl W/ Predictions Based on Reg Guide 1.99 Shows Good Agreement
ML18093B294
Person / Time
Site: Salem 
Issue date: 11/07/1988
From: Labruna S
Public Service Enterprise Group
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML18093B295 List:
References
RTR-REGGD-01.099, RTR-REGGD-1.099 NLR-N88169, NUDOCS 8811210114
Download: ML18093B294 (2)


Text

.., - -

.J Public Service Electric and Gas Company Stanley LaBruna Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-4800 Vice President - Nuclear Operations November 7, 1988 NLR-N88169 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

SURVEILLANCE SPECIMEN CAPSULE TEST REPORT SALEM GENERATING STATION UNIT NO. 1 DOCKET NO. 50-272 Attached, per the requirements of 10CFR50, Appendix H, Section III.A, is the technical report (WCAP-11955) on the surveillance specimen capsule "Z" which was withdrawn from Salem Unit 1 during the November 1987 refueling outage.

Comparison of test results for the Salem Unit 1 surveillance material with predictions based on NRC Regulatory Guide 1.99 Revision 2 methodology.shows good agreement.

A License Change Request (LC~) revising the Unit 1 heatup and cooldown curves to reflect these results will be forwarded to you by December 1988.

Should you have any questions, please do not hesitate to contact us.

Sincerely, Attachment

{

\\_,

.*\\

~...

l Document Control Desk c Mr. J. c. Stone Licensing Project Manager Mr R. w. Borchardt Senior Resident Inspector Mr. W. T. Russell, Administrator Region Ms. J. Moon, Interim Chief New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, New Jersey 08625 11-7-88