ML18093B212
| ML18093B212 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 10/06/1988 |
| From: | Miller L Public Service Enterprise Group |
| To: | Russell W NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| References | |
| NUDOCS 8810170501 | |
| Download: ML18093B212 (2) | |
Text
-
ACCELERATED.STRJBUTION DEMON.ATION.
SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:8810170501 DOC.DATE: 88/10/06 NOTARIZED: NO DOCKET #
FACIL:50-311 Salem Nuclear Generating station, Unit 2, Public Serv 05000311 AUTH.NAME AUTHOR AFFILIATION MILLER,L.K.
Public Service Electric & Gas co. of New Jersey RECIP.NAME RECIPIENT AFFILIATION RUSSELL,W.T.
Region 1, Ofc of the Director
SUBJECT:
Notifies that 881005 eddy current exam of Steam Generator 22 revealed 46 defective tubes of 84 inspected in Row 1.
DISTRIBUTION CODE: IE29D COPIES RECEIVED:LTR.rL ENCL.1].
SIZE:
(
TITLE: Licensee Event Rept (50 DKT)-Prompt Notification/24-Hour-=R~e-p~t~~-
NOTES:
RECIPIENT ID CODE/NAME INTERNAL: AEOD/DOA NRC OP CNTR NRR/DOEA/TSB 11 NRR/DREP/RAB 10 NRR/DRIS/SIB 9A NUDOCS-ABSTRACT RES DEPY GI RES/DSIR/EIB EXTERNAL: H ST LOBBY WARD NRC PDR COPIES LTTR ENCL 2
1 1
1 1
1 1
1 1
1 RECIPIENT ID CODE/NAME AEOD/DSP /TPAB NRR/DOEA/EAB 11 NRR/DREP/EPB 10 P/RPB 10 02
~~LRB12 Fl D,J
- RGNl FILE 01 LPDR NSIC COPIES LTTR ENCL 1
1 1
2 1
1 1
1 1
1 PIFASE HELP US 'ID REDUCE JmSTE !
CDNrACl' 'IHE r:xx::uMENl' CDNmOL DESK, BCX:M Pl-37.(EX!'. 20079) '10 ELIMINM'E 100R !mME FR:11 DI:s'l'RIBOTION L:IS'1'S !OR IXalMENl'S mu IlCB'T NEED!
TOTAL NUMBER OF COPIES REQUIRED: LTTR
{)
22 ENCL
~.J~~'
~
R I
D s
I A
D D
s R
I D
s I
A D
D s
CPS~G Public Service Electric and Gas Company P.O. Box E Hancocks Bridge, New Jersey 08038 Salem Generating Station Mr. W. T. Russell Regional Administrator USNRC, Region 1 475 Allendale Road King of Prussia, Pa.
19406
Dear Sir:
SALEM GENERATING STATION LICENSE NO. DPR-75 DOCKET NO. 50-311 UNIT NO. 2 October 6, 1988 TECHNICAL SPECIFICATION SURVEILLANCE PROMPT NOTIFICATION REQUIREMENT 4.4.6.4.B, TABLE 4.2-2 On October 5, 1988, eddy current examination of No. 22 Steam Generator (S/G)
~evealed fourty-six (46) defective tubes of 84 inspected in Row 1.
The tubes showed indications of single or multiple circumferential cracking in the tangent area.
As per Technical Specification Surveillance 4.4.6.2 this places the S/G in category C-3.
This notification is being made as required by Technical Specification Table 4.2-2 prompt notification (i.e., C-3 categorization) to the Nuclear Regulatory Commission pursuant to Technical Specification 6.9.1.8.
MJP:pc 8810170501 881006 PDR ADOCK 05000311 P
PDC The Energy 1-'eop1e Sincerely yours,
- ~
L. K. Miller General Manager -
Salem Operations