Text
~*
Public Service Electric and Gas Company Steven E. Miltenberger Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-4199 Vice President and Chief Nuclear Officer October 4, 1988 NLR-N88156 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:
SPECIAL REPORT ON SPARE CRDM WELD REFURBISHMENT SALEM GENERATING STATION UNIT NOS. 1 AND 2 FACILITY OPERATING LICENSE NOS. DPR-70 AND DPR-75 DOCKET NOS. 50-272 AND 50-311 In January 1988, Public Service Electric and Gas Company (PSE&G) personnel discovered several p'in hole leaks on six Salem Unit 1 spare Control Rod Drive Mechanism (CRDM) canopy welds.
PSE&G responded with a comprehensive corrective action program.
This program was communicated to NRC personnel during meetings held in King of Prussia, PA and Bethesda, MD on January 28, 1988 and February 4, 1988, respectively.
During these meetings, PSE&G committed to submit a Special Report summarizing our findings.
This Special Report is enclosed.
If you should have any further questions in this area, please do not hesitate to contact us.
Sincerely, Attachment 8810l303o58a i oo4 __________ ~,
- rw ADOCK osoo~~D2 A
ool
'\\I
- Document Control Desk c
Mr. J. c. Stone Licensing Project Manager Mr. R. w. Borchardt Senior Resident Inspector 2
Mr. W. T. Russell, Administrator Region I Mr. D. M. Scott, Chief Bureau of Nuclear Engineering Department of Environmental Protection 380 Scotch Road Trenton, NJ 08628 10-04-88