ML18093A700

From kanterella
Jump to navigation Jump to search
Forwards Rev to App a of 870731 Submittal Re Util ATWS Mitigation Sys Actuation Circuitry (AMSAC) Resulting from 880125 Telcon W/ R Steven.Rev Specifically Addresses NRC Concerns Re Isolation Devices on Output Side of AMSAC
ML18093A700
Person / Time
Site: Salem  
Issue date: 02/26/1988
From: Miltenberger S
Public Service Enterprise Group
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NLR-N88023, NUDOCS 8803040311
Download: ML18093A700 (7)


Text

..

- Steven E. Miltenberger Vice President -

Nuclear Operations Public Service Electric and Gas Company Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609 339-4199 February 26,1988 NLR-N88023 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

ATWS MITIGATION SYSTEM ACTUATION CIRCUITRY SALEM GENERATING STATION UNIT NOS. 1 AND 2 DOCKET NOS. 50-272/50-311 Public Service Electric and Gas Company (PSE&G) submitted plant specific information related to the Salem ATWS Mitigation System Actuation Circuitry (AMSAC) via PSE&G letters NLR-N87136 dated July 31, 1987 and NLR-N87231 dated December 24, 1987.

As a result of a phone call between Mr. R. Steven of NRC/NRR and PSE&G personnel on January 25, 1988, Appendix A of the July 31, 1987 has been revised.

A copy of that revision is attached.

The revision specifically addresses NRC concerns related to the isolation devices on the output side of the AMSAC and are noted by a vertical bar on the side of the paqe.

Should you have any questions, do not hesitate to contact us.

Attachment Sincerely,

(~-BS03040.311 B0_ ~855~72 PDR ADIJCK PDR p

1 I

I

"Document Control Desk 2

C Mr. D. C. Fischer USNRC Licensing Project Manager Mr. T. J. Kenny USNRC Senior Resident Inspector Mr. w. T. Russell, Administrator USNRC Region I Mr. D. M. Scott, Chief Bureau of Nuclear Engineering Department of Environmental Protection 380 Scotch Road Trenton, NJ 08628 February 26,1988

APPENDIX A AMSAC ISOLATION DEVICES Electrical independence of AMSAC from the existing Reactor Trip (RTS) is provided through several means for the Salem Generating Station.

Class lE powered isolation devices are provided to electrically isolate the protection circuits in the process protection cabinets from control grade circuits outside the same cabinets.

A block diagram showing the relationship of AMSAC to the existing RST is provided in Figure 4 which details the AMSAC/RTS connections and points of isolation.

The steam generator narrow range level inputs to AMSAC are derived from existing isolated signals from the process protection system.

These signals are provided from differential pressure transmitters to the process protection cabinet and then from the protection cabinet to the control cabinets and finally to AMSAC.

This arrangement does not require the use of new isolators to provide electrical independence of these instrument channels from the existing RTS.

However, to prevent overloading of the existing current loops, several isolators of the existing type were added.

For measuring turbine load at the first stage, Public Service Electric and Gas (PSE&G) has elected to utilize the existing turbine impulse chamber pressure transmitters, transmitter power supplies, and isolators associated with the 7100 process protection system.

As with the narrow range steam generator inputs, the isolated signals are from the RTS which have been routed through the control cabinets.

Isolation is provided in the process protection cabinet for the signals used as input for AMSAC.

As reported in the Westinghouse Protection System Noise Tests (Rev. 2, 1975), these isolation devices, which are powered by a class lE source, have been tested to demonstrate that the device is acceptable for its application.

The purpose of the tests was to determine whether or not protection circuitry could be perturbated to the extent that protective action would be prevented by the pick-up or presence of credible interference on control wiring in close proximity to protection wiring within the process control racks.

The system was subjected to tests that included noise susceptability, output cable voltage faults (maximum credible voltages: 118 VAC, 250 VDC), magnetic interferences and light emitting diode verification.

The acceptance criteria for these tests were (a) noise would not degrade the ability of the protection systems to provide the necessary action and (b) noise which causes initiation of protective actions would be reported and evaluated in a case basis.

Since the protection system operation was not degraded, no evaluation had to be made.

As mentioned, the subject of interferences that could negate protective actions was covered in various tests carried out for Diablo Canyon, for the Westinghouse 7100 Series Process control System Noise Tests.

This report includes a series of tests that

~ere performed before any faults or circuitry abnormalties were appl{ed.

These tests were carried out to demonstrate that a

  • credible perturbation in the control wiring would not degrade protection action or be reflected back into the protection wiring.

Any of these interferences (i.e., noise, crosstalk, etc.) that would be generated by AMSAC falls under the same category as those tested for in the test report.

Since AMSAC is separate from the reactor protection system and the cable is not routed in an area that exceeds the 118 VAC 250 VDC test limits, any interference from AMSAC would not affect the reactor protection system.

Under all tested conditions the protection circuitry operated as intended.

The test showed conclusively that electrical interference imposed into the isolator output wiring (control wiring) is not a consideration as to the proper operation of the perturbated channel nor any adjacent channels.

The recordings verified that the interference imposed onto the control wiring was not induced into the protection wiring.

The magnitude of the electrical interference introduced into the system and the stringent test procedures far exceeded any conditions that would be present in actual plant operations.

Isolation is also provided at the output of AMSAC for isolating the non-class lE AMSAC circuits from the class lE final actuator circuits.

For the Salem Units, the AMSAC outputs are provided from separate relay panels within the AMSAC cabinet.

Separation of the train A and B circuits within the AMSAC cabinet is achieved through a combination of metal barriers, conduit and distance.

Power for the output relay isolation devices is provided from an AMSAC internal power distribution system contained within the AMSAC cabinet and is not subject to voltages exceeding tested voltages.

A series of tests have been performed to determine the isolation capability of the AMSAC output relay (Struthers-Dunn).

The acceptance criteria for these tests were (a) the leakage path resistance/impedance would not be greater than one megohm to satisfy isolation requirements, (b) the leakage current would not exceed one milliampere to satisfy the dielectric requirements, and (c) the fault voltage would not degrade isolation (normal operation would be acceptable).

For one of these tests, the relays had been tested with the maximum credible fault (MCF) of 590 VAC applied to the relay coil in the transverse mode (Figure 5).

A closed contact was connected to a strip chart to determine the duration of the relay actuation (if any) during application of a fault to the relay coil and to measure the resulting induced voltage on the contact.

A second normally closed contact was connected to a DVM to measure induced voltage on the contact for tests on relays 2 and 3.

The fault voltage and induced voltage were measured and recorded.

The results are as follows:

Time for coil DVM Reading Record Reading Relay #

to open (volts)

(volts) 1 19.45 not observed 0.731 2

19.92 0.618 0.774 3

20.40 1.40 1.032

.The normally open contact closed as expected; no induced voltage

,was observed.

These results demonstrate that the relay provides isolation for the MCF specified.

DC voltage was not tested since AC voltage was considered to be more limiting.

The relays clearly demonstrated their isolation capability by limiting any propagation of the faulted conditions from the non-lE coil to the lE contact to a negligible value. This induced contact voltage (maximum of 1.4 volts) is determined to be well below industry standard pickup and dropout voltages for components typically utilized in the plant circuits.

Additionally, the SER requires that the isolation devices comply with the environmental qualifications and with the seismic qualifications which were the basis for plant licensing since they act as the boundary between safety related and nonsaf ety related circuitry.

For the Salem configuration, the AMSAC input isolation devices which were added to the 7100 process protection system are identical to the existing devices which were reviewed as part of the plant's original licensing basis.

The qualification of the AMSAC output isolation device has been performed in accordance with the current Westinghouse seismic qualification program.

This program has developed and implemented to meet the requirements of IEEE 344-1975, "IEEE Recommended Practices for Seismic Qualification of Class lE Electrical Equipment for Nuclear Power Generating Stations" for Westinghouse supplied instrumentation and control systems.

Also, the qualification of the AMSAC output relays has been performed for a mild environment based upon a material analysis of the relay.

The methodology for qualification is contained in WCAP-8587 Rev. 6-A "Methodology for Qualifying Westinghouse WRD Supplied NSSS Safety Related Electrical Equipment" and is Westinghouse's interpretation of the requirements of IEEE-323 1974, "IEEE Standard for Qualifying Class lE Equipment for Nuclear Power Generating Stations."

It is required that measures be taken to protect the safety systems from electrical interference (i.e., electrostatic coupling, EMI, crosstalk, etc.) that may be generated with AMSAC circuitry.

These measures for Salem are precautions in grounding of the AMSAC cabinet and internal circuits.

Also, the circuitry is in a free standing cabinet which would contain any generated noise.

The Class lE loads operated by the isolation relay contacts are powered from a Class lE source.

The plant specific details of the wiring configuration can be found on the the PSE&G elementary drawing if needed.

In summary, it has been demonstrated that the isolation devices used to isolate the safety related circuitry from the nonsafety related circuitry for AMSAC meet the requirements of the AMSAC SER Appendix A.

Through various tests and analyses it has been verified that the devices will provide electrical isolation.

t I

SAFETY RElATED TURBINE IMPULSE PRESSURE TRANSMITIERS FIELD SENSORS S/G N.R.LEVEL TRANSMITTERS I

I ISOL.

PROCESS I

PR01£CTION /1-'---------~'

CABINETS

~

PROCESS CONTROL CABINETS

  • I SSPS TRAIN A I I REACTOR TRIP FINAL ACTUATION DEVICES TRAIN A I

l

, I AM SAC

. - LOGIC TR.A TR.B ISOL ISOL RElAYS RElA"S I

I

~

SSPS TR.6JN 8 REACTOR TRIP FINAL ACTUATION DEVICES TRAIN. B FIGURE 4:

RPS - AMSAC BLOCK DIAGRAM CONTROL OUTPUTS

. r----------.,

I RELRY UNDE:R TEST I ---

RE:CORDE:R R

I I

I I

1 Jr!t-+---~--"----'\\1\\/\\----------...

I I

I I

I I

I I

I I

I I

I I

I I

I I

I 2

2~-.

3 30 4

40 5

5~::::::::::------i 6

6 ~*.....__,

11 7 0 v

10 8

9 9

14 r----"-.......f-0 10 0 13 i---.L...p...a 11 ra-.--.J 12 ----..p...a 12 7 ~----t-013~----_....~

COIL e 14~--

rRAMe:: --+-.... I o o I L---............ _

.FIGURE 5: COIL TO CONTACT INDUCED VOLTAGE:

D.C.

POWE:R SUPPLY POWE~

SUPPLY v

see vRc OR 2521 VDC

  • .I