ML18093A627

From kanterella
Jump to navigation Jump to search
Forwards Supplemental LER 87-017-02,addressing Results of Investigations Re Potential Effects of Steam Release on Equipment Adjacent to Steam Driven Auxiliary Feedwater Pump Encl
Date released: 11/29/2018 Download: ML18093A627


Forwards Supplemental LER 87-017-02,addressing Results of Investigations Re Potential Effects of Steam Release on Equipment Adjacent to Steam Driven Auxiliary Feedwater Pump Encl
ML18093A630
Person / Time
Site: Salem 
Issue date: 01/26/1988
From: Zupko J
Public Service Enterprise Group
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
Download: ML18093A630 (1)
LER 87-017-02:on 871113,six Leakage Pathways from Unit 1 Auxiliary Feedwater Pump Compartment 13 & One Pathway from Unit 2 Identified.Caused by Control of Design Requirements. Leakage Paths Sealed & Field Directive Will Be Issued
ML18093A625
Person / Time
Site: Salem 
Issue date: 01/26/1988
From: Pollack M
Public Service Enterprise Group
To:
References
Download: ML18093A625 (4)