ML18093A510
| ML18093A510 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 10/31/1987 |
| From: | Public Service Enterprise Group |
| To: | Caporale G NEW JERSEY, STATE OF |
| References | |
| NUDOCS 8712030429 | |
| Download: ML18093A510 (25) | |
Text
?UU-G_!~
!:_~_!I~ ~'I~!
~.!2!=.£CL _____ -
PO BOX 570 lOC NJ0005622 r-*-- 401 (11-lll)
Expir* 2-29-84 P'&,.MIT NUM*&R
---~~.ax.k.~~~llDL-----------
MONITORING PERIOD
~am~al~~Ge~~ating~t~io~------
Yll:AR MO I DAY I I Y&A" I Mo I DAY 1'QC&6.~~~~-Al~~ay~~~ek__ ________
P'ROM 87 10 I 01 I TO 87 I 10 I 31 (10-21) (22-ZJ I (24-ZJ)
(16*,U) (211-lfl) (JO.JI)
NOTE: Rud lnllrucllona belore compl*Ung Ihle lonn.
i x
(J Cerd Only J QUANTITY 011 LOAPIHQ (4 Card Only)
QUALITY 011 CONC&NTllATION PAllAM&T*ll (46-JJ)
(J4-61)
(Jl-4J)
(4'-JJ)
(JUI)
.HO...
(UJ7)
AV&llAQll MAXIMUM UNITe MINIMUM AV&llAQf;,
MAXIMUM UNIT*
r Ci1-4J, 00400 l
a AM PL&
M&AeUllDHNT 6.60 7.40 0
I pH Effluent Gross 6.00 9.00 SU RllQUl........ T I
00400 2
aAMP'Lll:
M'llAeUllll:MllNT 7.00 7.40 pH Influent P'CllNIT SU RaQUlll... ISHT 50050 l
ilAMP'LIE Mll:AaURll:Mll:NT NOTE 1 NOTE 1 Flow Effluent Gross P'PMIT RaQUlllUl*NT MGD 00340 1
8AMPLIE Mll:Ai1URIEM£NT*
NOTE 2 NOTE 2 COil Effluent Gross P&llMIT ll&QUlllUlllHT MG/L 00340 2
ilAMP'Lli:
COD Mll:AeUll£Mll:NT NOTE 2 NOTE 2 Influent
... ltMIT MG/L
.. aQUlllUl&NT 00340 4
- AMP'Lli:
COD MIEA*UR&MENT NOTE 2 NOTE 2 Effluent Net 50.00 MG/L RllQ\\llQMUIT 50060 1
eAMP'Lli:
0.09 0.28 2
Chlorine, Total MIEAeURli:MliNT MG/L Residual, sws
.. lll'llollT 0.20 Effluent Gross a&QUIRUilllNT NAMa/TITLll PRINCIPAL &X&CUTIVIE OP'P'IC&I' I CillTIFY Ul<OUI Pll<ALTY OF LAW THAT 1 HAV[ l'[llSOhALLY [AAMIN[()
T&L&PHON*
AND AM FAM*LIAll WITH TH[ ll<fORMATION SU-TilD HUICll< Al<D UKD J. Trejo ON MY ll<QUIAY Of TttOSl INOIVIOUAL6 1.... lPIATCLY 1116l'OH518L[ FOR OBTAINll'OG TH[
ll<fOAMATION I ll[Ll[V[ TH[ SU.... TI[D 1...-0AMATION IS TAUl ACCUllAT[ Al<O COM,,_CTI: I AM A*All[ THAT Ttt[lll AA[ 61G
/"}_~---;;;:;
Rad.Prot./Chem Mgr.
/'/(TV 609 1339-4399 l<lftCAl<T Pll<ALTl(S fOA su... 1TI11<G fAL5l 11<fOAMATION ol<CLUPll<G
- a~UR& OP' PRINC~L IEXllCUTIV&
TH( P05'51111L1TY OF fll<[ Al<O 1-AISOl<M[l<T SU Ill U!"oC I 1001 AND l'lu!itC
- 1318 *DQ'h** """,,.,., 11oh.,H 111*) 1nrlwd1 '"'" fllJ fu 11u.1M*1 TYPllD 011 PlllNTllD
- nd ur nt0.11m1t11t 1mpt19Ul1n1.. nr u/ lwfMoffrt 'Monlll* ellfl.ii.H*t* 1 P'f"ICli:R OR AUTHORIZllLD AGaNT
...... A I NUM*lll Discharge 481 is #11 condenser cooling water.
NOTE 2:
Unit. was out of service during report period.
NOTE 1:
Flow data unavailable as of report date.
Data will be included with the November report.
- PA form JJZ0-1 (Rev. I0.79)PR11v1ou* 1ED1TION To** u11&D
-'~
UNTIL aUPPLY I* DIHAUeT&P
~~
(Rlll"LACll:*.... P'ORM !*40 WHICH MAY NOT ** ue1D.)
8712030429 871031 PDR ADOCK 05000272 R
PDR P"*&QUllNCY eAMP'Lll:
OP" TYP&
ANALY.18 (64-61)
(611-711J
'2/31 GR 1/7 GR 2/31 GR 1/7 GR __
N/A NA CONT NA 0/31 GR 1/30 GR 0/31 GR 1/30 GR 0/31 GR l/30 GR 1 --
Peri.on
- l.
~eriod GR DAT*
87 11 24 YaAll MO DAV *-*
l
l"ERMITTIU: NAME/ADDREee (lnclud, Faci/11; Nam' /Lrx:allon i/ dltl,,,nl)
NATIONAL l"OLLUrANT DleCHARGIE !ELIMINATION *Y*TllM tNrDES)
DISCHARGE MONITORING. REPORT (DMR)
~~---GEN~r.t;R._:-_ENV~&~----------
(1-16) 17-19)
ADDREH PSE&G
P.O.oox570 lOC======
llJ0005622 481 l"ERMIT NUM*ER Dl*CHAllGE NUM*t:R NEWARK ___ ~J~710L _______
MONITORING PERIOD t:AC£1!.lll __ SALEM_GENERATING STAT.W.N -------
YEAR MO I DAY I I YEAR I MO I DAY
!:Q~TJ2."!___l.CWER_ALLCWAYJ2.. CREEKS_ -
FROM I
I TO I 87 I 10 131 87 10 01 fonn Appro'#d OMBNo.~
Expira 2*29-IU -
(20-2/)
(21-*IJ) (.14-.lJ)
(Z6*.l7} (13-19) (JO-JI)
NOTE: Read lnetruclloM before completing Ihle form.
x (J Card Only)
QUANTITY OR LOADING (4 Card Only)
QUALITY OR,CONCIENTRATION l"ARAMIETll*
(46-$J)
($4-61)
(Jlf-.fj)
(46..jJ)
(.U4JI)
NO, l'llllOUllNCY eAMPL*
01' (JZ-17) llX ANALY81*
TYP'*
AVERAGE MAXIMUM UNITe MINIMUM AVERAGE MAXIMUM UNITe 614JJ)
(6'-63)
(69-70) 00530 l
eAMP'LIE 2
MEAeURllMENT NOTE NOTE 2 MG/L' 0/31
- SOLIDS, TOI'AL r::R SUSPIDIDED
.. llRMIT
'Ii
- *l/30 EFFLUENI' GROSS REQUIREMllNT GR 00530 B
SAMPLE MS/L
- soLIDS, TOI'AL MEASUREMENT NOTE 2 NOTE 2
.0/31
~*
SUSI> ENDED
- ~.
NRMIT UJFLUENT RllQUIREMllNT
- li30 GR 00530 4
SAMPLE
- SOLIDS, TOr.7\\L MEASUREMENT NOTE 2 NOTE 2
~/L 0/31 GR SUSPENDED l'ltRMIT fil'i'LUENl' NET REQUIREMllNT 30.00 45.00 **
- 1/30 GR UU::>Sl l
SAMPLE PETROLEUM H'... 'DROCARBONS MEASUREMENT NOTE 2 NOTE 2
- 0/3]
I GR ID"'LUENT GROSS
.r.K;/L P'ERMIT RllQUIREMllNT
- ' 1/30 GR 00551 B
SAMPLE MEASUREMENT NOT& 2 NOTE 2 0/31 GR PETROLEUM H'.-.'DROCAROON MG/L INFLUENT P'llRMIT
- 1/30.
RltQUIRllMllNT GR 00551 4
SAMPLE PETROLEUM HYDRCCARBON MEASUREMENT NOTE 2
.NOTE 2 0/31 GR MG/L EPI'LUENT NET NRMIT 1r 10~00 RllQUIPlatM*HT
- 1/30 50060 l
SAMPLE CHID::UNE, Tal'AL MEASUREMENT N/A N/A MG/L I N/A GR RESIDU.7\\L
,cws
- 1 l"il:RMIT 0.2p EFFLUENT GROSS ltl:QUIREMl:NT
- PERIOD GR
,NAMIE/TITLE PRINCll"AL EXIECUTIVE OFP"ICER I CERTIFY UNDER P£NAL TY OF LAW THAT I HAY[ PERSOfriJALLY EXAMINED TllLllP'HONll DATii ANO AM FAMILIAR WITH THC INFO-ATION SUllMITT[D H[A[IN AND llASED ~
ON MY INQUIRY OF THOSE INDIVIDUALS IMMCDIAT[L Y RESPONSIBLE FOA J. Trejo OBTAINING TH[
INFOAMATION I BCLl[V[ THC SUBMlnED INFORMATION
( /"I IS TAU[
ACCURATE AND COMPL£TC I AM. AWARE THAT THERE* AA£ SIG Radiation Prot./Chem. Mgr.
NIFICANT PCNAL TIES FOR SUBMITTING fALSE INFORMATION INCLUDING 1339-4399 87 11 24 TH[ POSSIBILITY OF FIN[ AND IMPRISONMENT sec 18 use I 1001 ANO e1Gt(/TURE OF P'RINCl~;t IEXIECUTIVIE 609 31USC 'IJ19 tPrnalt.,* wadrr 111,.., 1tolulr1 m*.w 111rludr f1nr1 up tu 1w:111*1 TYPED OR l"RINTllD cuu/ ur 1'1anmum 1mpt1*onmrnt 11/ ltf'tuwn 6 montlu and-~.u*ar.* I OP"FICER OR AUTHOR!
D AGllNT
~~~!I NUMalElt YUR MO DA't COMMENT AND EXPLANATION OF ANY VIOLATIONS (Rr/urnrr "" """'*hmrnlJ hrrr)
NOTE 2:
Unit was out* of service during report period.
- 7 day average (REPLACEe EPA FORM T*40 WHICH MAY NOT BE UeED.J P'AGE OP' 2
20
IUll&-G_!: ~,!_al:. _!1~
~<J. ~ :!
.:**UI a&ll.Uil-f~_£G_ ___ _
PO BOX 570 lOC NJ0005622 482 P&RMIT NUM*&R
--_..Jie.Ji.iu:.k.....N-'1..Jl. 21.D...l-- - ---
~ - - - - -
MONITORING PER19D uaw~a1.!_m_~~~ating~tatio~------
YiEAR MO I DAY I Y&All I MO I DAY
~
Lower Alloways Creek P'llOM 87 10 I 01 ! TO 87 I lo r 31 l.QC&t.T~-----.--.---"'.---...,--------
(20-21) (21-lJ) (l4*lJ)
(16 *"7) C28-2P) (JO.JI)
. NOTE: RMCI lnatruollona.....,. compl*Un11 Ihle lonn.
(J c.,d Only)
QUANTITY Oil LOADING (4 C*d Only)
QUALITY OR CDNC&NTllATIDN PA*AM&T&*
(4'-jj)
(J4~1)
(JMJ)
(4'-JJ)
(JUI)
ND. P'll&QU&NC:Y
- QI' TVP&
ANALY*I*
8AMf'Llt ~1
(.IJJ7)
AV&llAClll MAXIMUM UNIT8 MINIMUM AV&llAG&
MAXIMUM UIUT8 6l~J)
(6441)
(6P-7U J 00400 l
8AMPL&
MllA8UR&M&NT 6.70 7.40 0
2/7 GR pH Effluent Gross P&UUT 6.00
- 9. oo*
SU
- .. 1/7 GR AMUl*llll*T 00400 2
I
- AMPLll GR MllA*URIEMIEHT 7.00 7.40 2/7 pH Influent HllMIT SU 1/7 GR
.... QUl*&MISHT 50050 l
llAMPLE NA-Ml:AllURl:Mli:NT NOTE 1 NOTE 1 N/A Flow Effluent Gross f'&llMIT
~
MGD CONT NA
... QUl*&MPtT 00340 l
a AMPLE NOTE 2 0/31 GR Ml:AllUREMENT NOTE 2 COIL Effluent Gross "llllMIT RScaUl*&MllNT MG/L 1/30 GR 00340 2
II AMPLE 0/31' GR Mli:A*UREMli:NT NOTE 2 NOTE 2 COD Influent f'&RMIT MG/L 1/.30 GR IHQUU!IMllNT 00340 4
II AMPLE NOTE 2 NOTE 2
- 0/31 GR COD M l:AllURl:M l:NT Effluent Net f'SllMIT so.oo MG/L 1/30 GR RMUl.... &NT 50060
.l
~
1 llAMPLli:
0.26 1.81 6
Period Ml:AllURli:MENT MG/L
- Chlorine,* Total 1
Residual, SWS P&llMIT 0.20
- !Period GR Effluent Gross As.QUl"IMllHT NAMS/TITL& f'lllNCIPAL &X&CUTIVE OP'P'ICllll I CillTIFY u.. ~R Pl.. ALTY OF LAW THAT I ""Vi..,ll50NALLY,._... co Tli:LUHON&
DATK 4NO.... f-ILIAll WIT.. T.. E... FORMATION su-nco H£R(IN ANO 9A&CD CJ. ~* -------===
J. Trejo*
ON MY lf<QU1RY Of THOS[ INDIVIDUAL& 1-[DIATlLY Rl5l'OHSlllL[ FOii.
OlllTA1.. ING T,.(
11<FOllMATION I IKLll:llE THC SU... 1TI(D 1.... 0llMATION
~
"V.,._
I /'-0 Rad.Prot./Chem Mgr.
I!> TRU[
AC CURA T( A.. O COMl'LCl'l I AM AWAll[ T.. A T TH[Rl AM SIG 609 1 339-4399 NlfoCA.. T PlhALTlfS fOR SU... ITIING ft.LS[ INFORMATION 1.. CLUDING 87 11 24
,.. £ P0&!>111iLITY OF fl"' ANO *-l&O.. Ml"' su: 1111 use
- 100.1 AND
- ~TUii& OP' PRINClf'UXllCUTIYll ll uStC. *l.19. l~rwAllw* """ rAr., al*l.. IH 1tte)' "'"'""' f*nt* tAP lu.llU.UUll TYPl:D 011 PlllNTllD u..-i U# 1111l.1emMm am,,,..,.,.,rnl ul M1111111'f'11 I"'""-* *114 *' )f'*H.1*
P'P'ICli:R Oii AUTHORI D ACl&NT
!!!~I NUMalll YKAll MO DA'(
- Discharge 402 is #12 condenser cooling water NOTE 2:.Unit was out of service during report* period.
NOTE 1: *Flow data unavailable as of report date.
Data will be
.included with November report.
PA fonn J320-I (R*w 10-79) PR&111ou11 1:D1TIDN TO *IE u**D UNTIL llUPPLY Ill UHAU8T&D Cll... LAC&8 &PA P'DRM T*40 WHICH NAY NOT *IE U8&D 0 >
PAGEj 0'20
.. 1111u1n** NAMIE/ADDRU* "'"'"'*
TecllUJ N-1Loc1111011 *I dlfl*""')
NATIONAL POLLUTANT Dl8CHAllQIE &LIMINATION *Y*TPI cNrDF.S)
DISCHARGE MONITORING REPORT (DAIR)
NAU~~-GEN~~--=--ENV~&~--~-------
V-161 17~P)
.!91!9.Uf __
PSE&G _________________.
~*~OOX2~JOc_ _________ _
482 UJO 05 22
,.&lllMIT NUM*IER Dl*CHAllGE NUM*EA NEWARK ___ ~J~710L _______
MONITORING PERIOD uam __
SALEM_GENERATINGST&Io.N_ ____ ~--
YIEAR MO I DAY I I HAii I NO I DAY J::!!C...ATJ2~_UlVER_ALLCWAYS CREEKS _________
P'ROM 87 10
- 87.
1-onn AfJINOtl<<I OMB No. 20f0.0004 f//Cpim 2-29-IU
- I 01 I TO I 10 I 31 (10-211 (11-lJ I Cl4-1J)
(1611) 1111-.211)
(JO-JI)
. NOTE: Reed ln*lrucllone befo,. compldng Ihle tonn.
(J CIUd Ortlf)
QUANTITY OR LOADING (4 Card OnlyJ QU4LITY OR,CONCIENTR4TION PAlllAMKTKll (46-JJ)
(J4..S/)
(Jll-4J)
(46-JJ)
.(.U-61)
NO.
(Jl-J7)
AVIERAQE MAXIMUM.
UNIT*
MINIMUM AVERAGE MAXIMUM UNIT8
.61"6J, 00530 1
eAMPLll NOTE 2 MIEA8UllltMllNT NOTE 2
- SOLIDS, TCJI'AL M:;/L SUSPF!IDED PltllMIT EFFWEm' GRalS llKQUllllMltNT 00530 B
8AM,.LIE NOTE 2
- SOLIDS, TOI'AL MEA8URIEMENT NOTE 2
~/L
- SUSPENDED NlllMIT Il~liJENT llKOUIREM*NT 00530 4
lllAM.. LE
- SOLIU5, TOI'AL MIEA*UREMENT NOTE 2 NOTE 2
~/L SUSPENDED
... otMIT r::TI1JENT NCT RKQUIRPl*NT 30.00 45.00 **
.l 8AMPLIE PE'.mOI..EUM H'... 'DROCAROONS MEAeUREMENT NOTE 2 NOTE 2 fil'rWENT GroSS lvt'.;/L P'll:RMIT lll[QUUt&MaNT 00551 B
eAM,.LE MEAeUREMIENT NOTE 2 NOTE 2 PETROLEUM H'.o.'DROCAROON MG/L**
m:'LUENT
.. ltRMIT llllEQUlllUlllNT 00551 4
lllAMPLE MEA&UREMENT NOTE 2 NOTE 2 PETROLEUM HYDROCARBON
- MG/L EFPLUENT NET NltMIT 10.00 ll&QUlll*M*HT 50060 1
SAMPLE:
'CHID!UNE I. TC11'AL MEASUREMENT.
N/A N/A MG/L RFSIDU'\\L, CWS Pl:RMIT EFFLUEm' GROSS lllEQUllll:M&NT 0.20 N.:1.M.1:/TITLll,.ltlNCl.. AL llXllCUTIVll OFP'ICl:R I CERTIFY UNOfR PENALTY 0,. LAW THAT I HAI/£ l'ERSONALLY OAMIN(O Tl:LKPHONI!
ANO AM FAMILIAR WITH TH( INFORMATION SUlllMITT[O H[RllN ANO lllASlO tLt?--W J. Trejo ON MY INQUIRY OF THOSE INDIVIDUALS IMM(IJl&T(L Y R[SPONSlllL( FOii OBTAINING TH(
INFORMATIOl\\I I B[Lll:Vl TH( SUllNllTTlO. INFOllMA TION
/r~,,,__
I IS TAU(
ACCURATC ANO COM~['T[ I AM AW*R[ THAT fH(fU AR( SIG NIFtCANT PCNALTllS FOR SUBMITTING 'ALSl INFORMATION *INCLUDING RadiationProt./Chan. Mgr.
609 1339-4399 TH[ POSSIBILITY or FIN[ AND IMPlllSONM(NT S(( IB use I 1001 AND 81Q~RE OF PRINCl.. AL/:J:IECUTIVIE llUSClll19,p,na/I"* undrr 1ltrer 1l*rutr1 mo~ 11t<l&tdr /Inn "P 111 11111111111 TYPIED 011 PRINTl:D a111/.1 ur "'aJ.*11111111 1mpr11unn1rnl uf ltrr11.,...11 & mn11rh* CJnd t,,.,,.* I O
ICER bR AUTHORIZE.
AQIENT
~!!~:I NUM9111 COMMIENT AND EX,.LANATION OF ANY VDOLATION8 IRrltrrncr "" """'hmrnts hrrr)
NOTE.2:
Unit was out of service durinq report ped od.
- ~ 7 day average l'll*OU*NCY
- AM,.LK DI' TYPK
.ANAl.Y818 (U-41)
(6P.70) 0/31 GR 1/30 GR 0/31 1/30
~
0/31
- .GR 1/30 GR 0/31 GR..
l/30 GR 0/31 GR 1/30 CR 0/31 GR 1/30 GR N/A GR 1
PERIOD GR DATK 87 11 24 YltAll MO DAY P'AGE4 o~o
a6U-'!!:~.E_a 1 _!1 ~n~
CJ.~! _:_ __!: i1v-=-~!.J2.. i r ~ __ _
6HIUl..f~.!..'!_ _____ - ------------
___ _!~~ox ~_z..0_10£ ------------
ll*IDJ NJ0005622 r-*-- 483
\\11*1111
,.&IUrllT NUM8&R Dl8CHAllQI[ Nufllll*KR
---~~.adJ~~llDL-----------
MONITORING PERIOD u~m~a~~~~~ating~t~io~------
Y&AR MO I DAY I Y*All I MO I DAY
~~c~~~Al~~ay~~~ek_ ________
FROM 87 10 I 01 I TO I 10 I 87 31 (20-111 (ll*lll (l4-lJ)
(16 lT) (28-1111 (JO-JI)
NOTE: Rud ln1truc:tlon1 belore compleUng lhll lonn.
x (J C a11J Ortl1)
QUANTITY QR LOADING 14' C '" Ort Ir)
QUALITY Oil C:ONC:*NTllATION PA*AMllT**
' (46-JJ)
(J4-41)
(Jl-4J)
(46-JJ)
(JUI)
NO. P'llllQUIU*CY aAM,.Lllt 01' TY,.I:
(.IJJ7)
ANALY818 AV&llAGI:
MAXIMUM UNITa MINIMUM AV&RAQ&
MAXIMUM UNITa U-4J)
(64-4.9)
(611-7U1 00400 l
a.t.M,.L*
M*AaUllUl&NT 6.80 7.40 0
2/7 GR pH Effluent G~oss
,.&... IT 6.00 9.00 SU
- 1/7 "MUlltDl... T GR 00400 2
aAM,.LI:
Ml:AaUlll:Ml:NT 7.00 7.40 217 GR pH Influent HllMIT
- 1 /7 GR.
11*ou1*U1SNT SU 50050 l
8AM,.LE N/A NA M&AaURli:MENT NOTE 1 NOTE 1 Flow Effluent Gross PPMIT CONT NA M&OUl*Ul*NT MGD 00340 l
lllAMPLE NOTE 2 NOTE 2 0/31 GR COG MEAaUREMENT
'Effluent Gross
,.l:llMIT MG/L 1/30 GR "aQUl*... llNT 00340 2
8AM,.LE 2
2 GR MltA8UREMENT NOTE NOTE COD Influent
,..llMIT MG/L 1/30 GR ll&QUl9'UlllNT 00340 4
a.t.M,.LE NOTE 2 NOTE 2 0/31 GR MEA8URltMltNT 0
COD Effluent Net l'&llMIT MG/L 1/30 GR
"""'.... ~
so.oo 50060 1
.L GR
- a AM PL I:
Chlorine, Total M&A8URl:MltNT
<0.01 0.10 MG/L Period Residual, sws P*llMIT
.1 llloQUlallM&NT 0.20
- Period GR Effluent Gross NAll&/1'1TL& PlllNC:IPAL *X&C:UTIVIE OP'P"IC:&ll 1 Ci*TlfY u.. 0£R Pll'<ALTY OF LAW THAT I HAii[ l'Cll5ol.ALLY UIAMIN[O T&L... HON*
DAT&
A..0 AM FAM1L1All WITH TH[ 1.. FOlilMATION SU8MITI[0 H[RllN AND 9AKO J. Trejo ON MY lf<QU1RY OF THOS[ INOl\\llCIUALS 1-[0IAT[LY ll[~S-[ f(lfl y_~
OBTAl.. ll<G TH[
1Nf'ORMAT~ I 8lLll:ll[ TH[ SU... *TIIO INf"OllMATION Rad.Prot./Chem Mgr.
IS TRU[
ACCUllAT[ A.. D COMl'L['T[ I -
AWAll[ THAT THUii All£ SIG
.. IF.CANT PlNALTlf5 FOR su.... n.,.c; fALS[,,.FORMATION
""CLUOING 609 1339-4399 TH[ POSS1BILITY OF fll<[ A.. D 1-AISQl'IM[.. T Stt IB USC t 1001 AND alGN#UR& OP' PRINC:IP~l:X*C:UTIV&
87 l l 24
)') U &C t 1l1 &
1frrwallwa Mltdr' 1*rer el&lwlH 1Hey 111c*ttdf' /1110 MP IU llU.IJUU
~::~~I TYP*D OR PlllNT&D and ur m.Q.um...,.. *mpru1u11nwnr ul hrl....,.,,. ""'"'* *1td.\\,,..,. 1 OP"P'IC:l:R OR AUTHORI D AG*NT NUM*&ll Y*All MO DA\\
c;olllMl:HT AND llXPLANATION OP" ANY VIOLATIONa (R*/*Hnc* "" ""
1116 "",..,.
Discharge 483 is #13 condenser cooling water.
NOTE 1:
Flow data unavailable as of report date.
included in the November report.
Data will be NOTE 2:
Unit was out of service during report period.
PA Fo,. ~Z0-1 (Rew 10-79),.R11v1oue 1tD1T10N TO *11: u*&D UNTIL aUPPLY I* ltXHAUaTl:D (ll... LAC:U IEPA P"OllN T*40 WHICH NAY NOT ** ua&D.I PAGE 5
OF 20
PUUUTT*K NAM*/ADDIUE** (111Cld*
F<<""J N- /Loc*IW. I/ tlltl*n111)
NATIONAL POLLUTANT Dl*CHARQa llLIMINAllUN *Y*laM DISCHARGE MONITORING REPORT (DAIR)
~Y~--Gm~lGt._:-_m\\T~&~----------
(1-161 17-19)
- ~em __ ffiE~-----------------
!I.JO 05 22 483
____ __!1.0...:... BOX _i7Q_JOC __________ _
P'l:RM IT NUN *llR 018CHAllGI: NUM81:11 NEWARK ___ JJJ _07101 ________
MONITORING PERIOD u~m __
SALEM_GENERATrnG~~I~-------
Yl:AR MO I DAY I YIEAR I MO I DAY
!:2C_6..TJ2f!,__LCJVER_~$ ~---------
f'ROM 10 I 01 I TO 87 !
87 OMB No. 20l<J.0004
- E1tpirea 2*29-IU 10 I 31 (10-11)
(ll*l.I) ('4*1')
(l6*l7) 1111-191 (JO-JI)
NOTE: Read lnatrucllona belol9 completing.... tona.
x (J Ca*d OnlY)
QUANTITY OR LOADING (4 Ca*d Only)
QUALITY OR CONCIENTRATION PARAMIETIE*
(41l-JJ)
(H-61)
(Jl-4J)
(46-JJ)'
(J4-41)
NO...... QU&NCY eAMP'Llt
- X 01' TYP'&
(J2-J7)*
ANALY818 AVli:RAGE MAXIMUM UNITe MINIMUM.
AVl:RAGI:
MAXIMUM UNITe ll2-4J)
(64-41)
(69-70) 00530 1
eAMP'L*
- SOLIDS, TOI'AL*
M &AeU R*M llNT NOTE 2 NOTE 2 0/31 MJ/L r.:n SUSI>~
P'RRNIT EF'FI1Jrnl' GROSS RRQU llUEN&HT
- 1/30 GR 00530 B
eAMP'LI:
- SOLIDS, TOI'AL MEA*URl:MIENT NOTE 2.
NOT~ 2 M:i/L 0/31 GR -
SUSPENDED NRMIT Il.Wll.JENT R&QUIREM*NT
- 1/30 SR 00530 4
- AMPLE
- SOLIOO, TOI'.Z\\L MEA*UREMENT NOTE 2 NOTE 2
?w(;/L 0/31
('Jl SUSPENDED P&RMIT r::::LIJ.JENl' NET R*QUIRID.. NT 30.00 45.00 **
- 1/30 GR UU::>:)l 1
.*AMPLIE PETROLEllM H'... 'DROC.ARBO..~S MEA*UREMENT NOTE 2 NOTE 2 0/31 GR E:'FWEtll' GROSS l-~/L PERMIT R*OUIRllM*NT l/30 GR 00551 B
- AM.. LE MEA*UREMENT NOTE 2 NOTE 2 0/31 CR PETROl..EUM H'IDROCARDON MG/L INFUJml' P'*RMIT RIEOUIR*M*NT 1r
- 1/30 CR 00551 4
II AMPLE PETROLEUM HYDRCCARBn"'l MEAllUREMENT NOTE 2 NOTE 2 0/31 MG/L GR EFPLUmll' NET paRMIT 10.00 e
11*ou1R*M*HT 1/30 i 50060 1
llAM.. Lli:
Oil.OfilNE, ~
MEASUREMENT N/A N/A MG/L N/A GR RESIDU\\L,
WS
.. SRMIT 0.20 1
EFFLUml' ~s IHIQUIRIM*NT
- PERIOO GR NAN*/TITLI:.. RINCl.. AL *XllCUTIVIE OP'P'ICll:A I CIATtr't UNDER P(NAL TY OJ" LAW THAT I HAV( PCA'SONALLY lXAMIN[D T*L*P'HON*
DAT*
ANO AM fAMILIAA WITH THE INf'Qf'MATl()toj SU8MlnlD H[A[IN AND DASl.D
>fr£... (~
Trejo ON MY lf.fQUIAV OF IHOS[ INDIVIDUALS IMM[OIAT(LY ll[Sl'ONSIBL[ rQft J.
OBTAINING IH[ INfOAMATION I Bl:Ll[V[ TH[ SUllMITI[O 1NrOAMATl()N IS TAUl ACCUllATl ANO C0Mf'l.£T[ I AM AWAA[ THAT IH(AI AA( SIG Radiation Prot./Chan. M:Jr.
frllllflCANT Pfrr.AL 11(5 rOR SUllMITIING *ALS[ 1Nr01tMA TION INC:LUOING 1339-4399 THF P05St81lll'f Of" F"1N( ANO 1MPAISONM[NT SU IB use I 1001 ANO e1at)'TURll: OF P'RINC:~ ll:Xl:CUTIVll: 609 87 11 24 11us.c; '1)19 rfrt\\altw* "'""" lllrw 1lafulr1 "'*" 1ttrludr /111,. 11.p lu lll1UIJfl TY.. l:D OR ~AINTllD arad ur "'*~Unum 1"1pr11unmrnr,,,,.,.,...,..,.Ii munt'-* and.it \\ftll* 1 Of'f'ICli:R OR AUTHO li:D AGllNT
~~~!I NUM*IR Yl:AR MO DAY
- COMMl:NT AND IEX.. LANATION OF ANY VIOLATION* (RrJ,,rnu "" &Jllu1*h,,,rn1J hru)
- - 7 day average NOTE 2:
Unit was out of service during report period.
(RIE.. LACl:e EP'A P'ORM T*40 WHICH MAY NOT *11: U*llD* I P'AGI: 6 OP 2 O
NJ0005622 11-19)
EJ<pir* 2-29-84 l*ll>)
484 f'lllUUT. NUM*llR Dl8C:HAllCU: NUMe&ll
-~-~~~J~~llQj_ ___________
MONITORING PERIOD u~m~al~_Ge~~ating~ta_!_io~------
YllAR MO I DAY I YllA" I MO I DAY
~TJ2'1!!~~~~~~ay~~~eK__~-------
FROM 87*
10 I 01 I TO I lo I 87 31 (20-21)
(22-JJ) (J4-2J)
(26 27) (211-111) (JO-JI)
NOTE: Read lnatrucllone belora compleUng Ible lonn.
x (J CGtd Onlr l QUANTITY OR LOADING
( 4 c..,4 Onlr)
QUALITY O" C:ONC:*NTllATION PAllAM*T**
(46-JJ)
(J4-61)
(Jl-4J)
(46-JJ)
(JUI)
NO.
u (Jl.J7)
AV*llAGll MAXIMUM UNITe MINIMUM AV*RACiE.-,
MAXIMUM UNITe 6l-6J) 00400 l
eAMf'LI:
N&AeUllUHNT 7.00 7.40 0
pH Effluent Gross P&llMIT 6.00 9.00 SU RIOUtltll!l... T 00400 2
- AMPLll M llAeU lll:M ENT 7.00 7.40 pH
.Influent
""MIT R&OUl"SMPT SU 50050 l
114Mf'LIE Flow MllA*URllMENT NOTE 1 NOTE 1 Effluent Gross f'UNIT R*OUlllUl&NT MGD 00340 1
llAMPLIE COG MIEAllUREMIENT 250.00 250.00 Effluent Gross f'llllMIT "aQUlaUl&NT MG/L
- 00340 2
llAMP'LIE M£A*URIEMENT 180.00 180.00 coo Influent
.. llRMIT RaQU19'&MlllNT MG/L 00340 4
- AMPL£ MEAllUR£M£NT 70.00 70.00 1
COD Effluent Net
.l"&llMIT MG/L RSQUl.... &NT 50.00 I 50060 1
llAMPLIE
<0.01 0.04 MIEAlllURIEMIENT 0
Chlorine, Total Residual, sws
... "J*UT a&QUH*PllPIT 0.20 M:;jL Effluent Gro!=:!':
NAMa/TITL.11 P"INC:lf'AL llXllC:UTIVIE OFFIC:ll" I ClRTIFY UNOUI PlNALTY OF LAW THAT 1 HAii[ f'[RliONALLY lKAMIN[D TllLll.. HON*
ANO AM fAMILIAll WITH THC lflffORMATIOH SUOMlnlD H£R[IN ANO U61:0 J. Trejo ON MY lhQU1RY OF THOS( INDl\\llDUAL5 1-(CIAT(L Y R(SPQH5111L( FOii
(},.~~
OBTA1flil1NG TH(
lhlf'OfUrllllATtON I B[Ll(\\I[ TH( su-on[O 1"'8'0llMATION Rad.Prot./Chem Mgr.
I!> TRU[
ACCURATl ANO COM.. L[T( I AM AWARl THAT TH[lll AR( SIG
~
v-l"re&f1CANT PlhALTI(!> FOft su-1n1NCO fALS[ INFOftMATION lfrtC:LUOlhlG 609 1339-4399 TH( POl>!>o81LITY ~ FIN( A.. 0 IMPRl!>ONMCNT SEC IB use
- 1001 ANO
- l~~URll OF f'RINC::~L l:XllC:UTIVll ll u &C
- 13111 1P.tWllw* """,,.,., *1011.rn n1*1 rnr*..J, /mu..,, ru llU.IMIU TYP'llD 0" f'IUNTllD und 111 11U1.11m..m 1mpr1*u1ut1f"t1I o/ lwluttn
- mu11tlh a1td.t _)'r*t* 1 FFIC:IER OR AUTHO IZED AG*NT
- ~
- :I NUMallR COMMaNT AND llX.. LAHATIOH OF ANY VIOLATION* (11.*l***M* &lll &lll.,.;hrn*nta Mt*)
Discharge 484 is #21 conderiser cooling water NOTE 1:
Flow data unavailable as of report date.
Data will be included with the November report.
r>A form 3320-1 (Rav IG-79) PR11v1ou* 1:D1T10N TO *E u*&o UNTIL *Uf'f'LY le ltXHAUeTllO IRllP'LAC:IH l:f'A FORM T*40 WHICH MAY NOT *I: ue110.i P"ll&OU&NC:Y eAMf'Lll:
01' TYP'lll ANALYe1a (114-611)
(69-7U I 2/7 GR 1/7 GR
'J./7 GR 1/7 GR N/A NA CONT NA 1/31 GR 1/30 GR 1/31 GR 1/30 GR l/31 GR 1/30 GR GR-J,.
PERIOD GR DAT*
87 11 Y*AR MO PAGE 7
24 DAV OF 20
-1
f'llR*llnll* NAMll/ADDRE88 (lnclud*
Foc*141* N.-/Loca1io11 1/ dl(J~un1)
NATIONAL P'OLLUTAN'f Dl8CHARQll ltL.IMINAllON *Y*1aM DISCHARGE MONITORING REPORT (DUR)
~g~--~~.__:-_ENV~&~--~~-----
~~~--reE&~----------------
(1-/6) 17-/9)
UJOOOS 22 484.
____ _!'...:_0...:_ BOX 2_7Q__]..OC __________ _
PltRMIT NUM*l:R Dl*CHAllGE'. 1*uM*llA
--~--NEWARK ___ ~J~710L~------
MONITORING PERIOD Uec&lll--SALEM_GENERATING.fil'ATI~-______
Yl:AR MO I DAY I I YIEAR I MO f DAY
!:QC..A.TJ2'!.-_I.1JNER_AL'f.DVAYS ~--- ______
FROM I
I TO I, n I 87 10 01 87
"::11
'-**** * *rr* ----
OMB No. 2040-0004
. Expira 2-29-IU (10-2/)
(11-l.f) (l4-lJ)
(16 lT) (28-19) oo:n>
NOTE: R**d lnatructloM baloN completing.... form.
C><
(J Ca,d Onlr>
QUANTITY OR LOADING (4 Cord OnlY)
QUALITY OR CONCENTRATION f'ARAMllTll*
(46-JJ) 1'4-61)
(Jl-4J)
(411-JJ) '
('4-41)
NO, (J2-J7)
IEX AVERAGE MAXIMUM UNIT8 MINIMUM AVERAGE MAXIMUM UNIT*
112-llJ 00530 1
- AMf'Lll
- SOLIDS, TOl'AL MIEA*UllllMIENT 216.63 477.50 M:i/L SUSI>~
f'llllMIT EFFWEm' GROOS lllllQUllllltMllNT 00530 B
- AMP'LIE MG/L
8AMP'LE
- SOLll6, Tar.l\\L MEASUREMENT 55.00 110.00
~/L 2
SUSPENDED f'lllllMIT
~
NET RllQUl*IEMllHT 30.00 45.00 **
00551 l
&LE PETROIElll-1 H'...'DROCARBONS MEASUREMENT 0.10 0.10 E?PWEtn' GIDSS lwri/L f'l:*MIT lllllQUIAl:MllHT I
I 00551 B
llAMP'LE 0.30 0.30 MEASUREMENT PETROLEUM H'..:.'DROCAROON MG/L IlU'LUENT f'llAMIT RIEQUl*llMllNT 00551 4
l!IAMP'LE MEASUREMENT 0.00 0.00 0
PETROLEUM HYDRCC.ARBON MG/L EFP.L[Jfilfr NET NltMIT 10.00 JllQUIRllMllNT 50060 1
&LE N/A MEASUREMENT N/A CHID!UNE, TC1I'AL MG/L RF.sIDUAL I cws P'lllllMIT EFFLUEm' GROSS
- IEQUIRl:MllNT 0.20 NAMll/TITLll P'RINCIP'AL l:XECUTIVll OFFICl:A I C(AT1rv UfliilO(R P(NAL TY 01" LAW THAT I HAVE PCASONALLY CX&MlfrtEO
~,z~
TllLllf'HONIE ANO AM rAMILIAR WITH THE INfOAMATION SUllMln[O H[R[IN ANO BASlD Trejo Oft MY INQUIRY Of' THQS[ INDVIOUALS IMMIEOIAT[L Y RIESPONSIBLI f"Oft J.
OBTAINING TH(
INFORMATION I
BlLtl:Vl TH[
SU8Mln[D INf'OAMATIOH IS TRUl ACCURATE A"D COMl'L(TI: I AM AWAlll THAT THERE AA( SIG Radiation Prot./Chan. Ivtjr.
NlflCANT PC,_.ALTl[S FOR SUlllMITTll<G
- ALS[
l"FOllMA TION INCLUDING 609 1339-4399 TH( POSSIBILITY OF Fl"( AHO IMPlllSQNM["T Sll I 8 USC
- 1001 A.. D URIE OF P'RINClf'A'L:d*CU.TIYll lJu5C:ttJl9 IPrnellw* wndrr 11tr11 1l*tu1n '9'1*w utrludr /1nra Mp fu llU llCll*
81G TYP'l:D 0111 P'RINTID q1td ur "'* 1111u1m 1mpr111m1t1rhf o/,.,,.....,,. IS mnnf/U eild.Iii u**,. I FICIER OR AUTHORIZE AGllNT
~!~-:I NUM*llll COMMENT AND EXP'LANATION OF ANY YIOLATION8 IRr/,,,nrr oJll <1llu**hmrn1J hr")
l'llllQUllHCY
- AMf'Lll 01' ANALY*I*
TYf'll
. (114-111)
(llP.70) 2/31 r.R 1/30 GR v::n GR 1/30
~ -
2/31 en -
1/30 GR 1/31 GR l/30 GR 1/31 CR 1/30 GR 1/::11 GR 1/30 -
N/A I
GR*
1 PERIOD GR DAT II 87 11 24
.YllAlll MO DAY
~AGE OP 8
20
I.
IUU-G_!: ~
!:.'!..!. _!t~ n~ <! ~ !
AllUU_g2,!!..!_~---- -
PO BOX 570 lOC Env. Affairs
---~~JU:kJ~~llilL-----------
uam~a~~Ge~~ating~ta_!.io~-----~
1.QQT~~.!_r_Al.!_o~ay~_£~ek _____ _:_ _ _...._
NJOG°05622
,.&llMIT NUM8&R MONITORING YltAR
'MO I DAY I FROM 87 10 I 01 I TO 17-19>
485 hpir* 2-29-84 Dl8CHAllQ& NUM8&11 PERIOD Y&All I MO I DAY 87 I 10 T 31 (20-21) (2l-lJ) ('4-lJ)
(l6.11) (23-10) (JO-JI)
NOTE: Read lnllt'Uetlona Mlore complellng Ihle 1onn.
- I x
(J CMd Onlr)
QUANTITY Oil LOADING (4 CM' Onlr)
QUALITY Oil CONC&NTllATION PAllAM&T&a (46-JJ)
(J4~/)
(JMJ)
(4'-JJ)
(JU/)
NO, llX (JJJ7)
AV&llAQlt MAXIMUM UNIT8 MINIMUM AV&llAQ.
MAXIMUM UNIT*
62-4.J)
I 00400 1
8AMPL&
M&A*UllDl&NT 6.30 7.20 0
I pH Effluent Gross PPMIT 6.00
. 9
- o ci*'**:
- .:.. -~.....
llllQUtHIQNT SU
- ~ :;:
~
00400 2
8AMPL&
f M llA8UlllUl&NT 1.oo*
7.40 pH I
Influent PSRNIT II!
ll&QUl*&MSNT SU 50050
.l 8AMPLIE Flow M&A*UR&MltNT NOTE 1 NOTE 1 Effluent Gross PPMIT ll&QUl.... &NT MGD i
00340 l
- AMPLIE 260.'00 26,0. 00 CDD MIEA*URIEMIE:NT
- Effluent *Gross P&llMIT MG/L.
- lllCIUllllNloNT 00340 2
&LE 160.00 160.00 Ml£A8UREMltNT COD Influent.
P*RMIT MG/L RSQ\\llll&M&HT 00340 4
- AMPLE:
100.00 100.00 Ml£A8UR&MltNT 1
COD Effluent Net NIUllT MG/L llSQUtll&NllHT so.oo 50IT60 l
- AMPLE:
Chlorine, Total MltA*URIE:MltNT
<O.Ol 0.01 0
K;fL Residual, sws Pli:llNIT 0.20 Effluent Gross A&QUllllU4&NT NAM&/TITL& PRINCIPAL &X&CUTIVIE: OP'P'IC&R. 1 CillTIFY U"l>LR rt:"ALTY OF LAW THAT I HAii[ P'[R~ALLY [llAMINCO T&L&PHON&
ANO AM f-ILIAll WITH TH[ 1.. fOllMATION SU-TT[D H[R[IN. AND 8A6C0 J. Trejo Of< MY lhQU1RY Of, THOS[ INDIVIDUAL& 1-CDIATELY 11£Sl'ONS18L£ fOfl OBTA1.. 1NG THC INFORMATION I.. Ll[\\I[ THC SU11M1TTID INFORMATION
/""/" ~ v,,,..,
I,/k-Rad.Prot./Chem Mgr.
IS TRU[
ACCURATC A.. D COMl'LCT[
- I AM AWARC THAT THllli Ali& &IG 609 I 339-4399 N1f1CAP<llT Pt:"ALTICS FOR Su... ITTING fALSI INfORMATION INCLUDING
- G'tSfu11a OP' PRINC,l~~J1tx&CUTIY&
TH[ P0&!>181LITY CY flNl AND IMl'RISONMlhT SU IB US.C t *1001 AND llUSC t lll8 1htWll61* """",,.,.. HOIMIH,,,.y 1ndll!fN /ann MP,., llU,IMlb
~!!~I TYP&D Oil PIUNT&D end ur m*.11mU111 1mpt19Ullmrnl u/ IWIMftft I M011lla* *"".i.,.,.,. 1 Ol'l'ICER OR AUTHOR D AG*NT NUMa&R Discharge485 is#22 condenser *cooling water NOTE 1:
Flow data unavailable as of report date.
Data will be included with the November report.
~A fo111t lU0-1 (Rev 10-79) PR11:v1ou* !EDITION To *1: u**D UNTIL *UPP~Y 18 PHAU*T&D.
(R&PLACIUI &PA FORM T*40 WHICH NAY NOT a& U8&D.J Pll&OU&NCY 8AMPLlt or TYP&
ANALY818 (64-411)
(69-7UJ 2/7 GR I
~/7 GR
')./7 GR i /7 GR __
NA NA CONT NA 1/31 GR 1/30 GR 1/31 GR l/~O GR 1/31 GR 1/30 GR r
GR.
Period l
PERIOD GR DAT II:
87 11 Y&All MO PAGE 9
24 DA\\
OF 20
P*IUUTT** NAM*/ADDRI:** (l11cliA1ll*
TecllllJ N-1LacG1lo11 1/ tlllfJ.,*nl)
NATIONAL l"OLLUTANT Dl*CHARGI *LIMINATION *Y*TllM 1Nl'DES)
~g ___
GEN~l-liR~_Em~~~----------
DISCHARGE MONITORING REPORT (D/tlR) l1*16J
. 17-IP)
!!!l!!LUl-_J?SE&G ______ --*------- -
UJ0005 22 485 P.O...:.. BOX 2_7.Q__J.OC __________ _
l"ll:RMIT NUM*l:R Dl*CHAllGIE.. UM.Ill NEWARK ___ ~J~710L _______
MONITORING PERIOD u~w __
SAI.m_GENERATI~ST~I~-------
Yl:AR MO I DAY I I Y*Alt I MO I DAY
!:eC.A.TJ2.'L._lil'JER_AI...LCl-JAY~ CREEKS_ - -
P"ROM I 01 I TO I 10 I 87 10 87 runn l'llJP'Oft!U OMB No. 20fO-OOtH EMpi,.. 2*29-84 31 (20-21)
(22-21) (14-lJ)
(16*17) ll"*lP) (JO-JI)
NOTE: A**d lnatructloM before completing.. fora IX (J Card Only)
QUANTITY OR LOADING (of Card Only)
QUALITY OR CONC*NTRATION PARAMllTll*
(46-JJ)
,,,~,,
(Jl..fJ)
(46-JJ)
(JUI)
NO. **
(Jl.J7)
AVl:ltAQE MAXIMUM UNIT8 MINIMUM AVl:RAGI:
MAXIMUM UNIT*
U-4J I
00530 1
- AMPL*
- SOLIDS, TOI'AL M*A*UltllM*NT 397.50 39'7. 50 M:;/L.
- ISUSP~
PllRMIT EFFWEm' GROSS ltllQUUllENllNT 00530 B
- AMPL*
- SOLIDS, TOI'AL MEA*URllMll:NT 457.50 457.50 M3/L SUSPENDED HltMIT Il-WllJENI' ltllQUUt*MllNT 00530 4
- AMl"LE
- SOLIDS, TOI'.ZU:..
MEAaUREMENT 0.00 0.00
~/L 0 SUSPENDED NltMIT I:?t'ilJEm' NET ltllQUIRllMllHT 30.00 45.oo**
OO:>~l.
1 llAMPLE PETROLEUM H'... 'OROCARBO..~S Ml:A*UREMENT 0.20 0.20 EFFUJEln' GNOSS M:J/L
.. IRMIT RIQUIR&M&NT
~
00551 B
- AMl'LI:
MEA*UREMENT 0.10 0.10 PETROLEUM H'.'DROCARI30N MG/L INFLUENT
.. llRMIT R *a U I It llM llNT 00551 4
-*AMl'LE PETROLElM HYDROCARBO..\\J MEAaUREMENT 0.10 0.10 MG/L 0
EFPUJEtll' NET
... IUllT 10.00 IHQUIRllMllNT 50060 1
- AMl'LE OIID!UNE, TaI'AL MEASUREMENT N/A N/A M:;/L RESIIX.l'\\L, cws l"lllUllT EFFLUWI' GRUSS ltlEQUlltllM&NT 0.20 NAM&/TITLll l"RINCIPAL llXllCUTIVll OF'P"ICllR I C(AT1rv U"40£R Pf,.,AL TY Of" LAW THAT I HAVC P'[RSOfritl,.LLY [XAMlfrit[O TllLllPHON*
AHO AM,.AMILIAR WITH TH( IW()ftMATION 5U8Mln[O H[lllt[IN ANO DAS[D
(}-f 'fH Trejo Qf-.,
MY INQUIRY Of' THOS[ INDIVIDUALS IMM£DIAT[LY A£SflONS18LI f"QR J.
OBTAINING TH[
INrQflMATIOH I lllLll:V[ TH[ SUlllMITT[D IHf"OAMATION IS TNUl ACCUAAT[ ANO COMP'l.£T[ "I AM AWAllC THAT TH(ll( Allt" SIG Radiation Prot./Chan. ~r.
frrif1J1CA~T P(NAL TICS rOll SUllMITTING *ALS[ 1NrQ11MATIOH INCLUDING 609 1339-4399 TH( POSS*ll*LITY Of' rlN[ ANO IMPlllSOHM[NT SU Ill use I 1001 AND elGN~-ltll OP" PR INC IP~
~X*CUTIV*
l"JUSCl1l19,p,,..,,,,. '""' '""",,.,.,,,. fh** "'""',,,,,, "",,,,,,, ***,
TYPllD OR l"RINT&D ortd ur "'*um..,.. ""P'H11,.111rnf u/ Mflil.,...11 l'5 """'* 011d.I\\ "'*" I OP"F'ICl:lt OR AUTHOIU AGllNT COMMl:NT AND l:Xl"LANATION OF ANY VIOLATION* IRtlrrrrtu "" """'hmrrtlS htrr)
- 7 day average l PA Form 3320-1 (Rev. I0-79)1"RllVIOU* l:DITION To** UHO UNTIL *Ul"PLY I* *XHAU8Tl:D llt... LAC** &PA P"ORM T*40 WHICH MAY NOT*& U**D.)
~~~!I NUM*llR Pll.QU*NCY 8AMl'Lll OP TYPll ANALY*I*
(U-411)
(6P.70) 1/31 GR 1/30 GR 1/31 GR l/30 SR 1/31 GR 1/30 GR 1/31 GR 1/30 GR 1/31 GR 1/30 GR 1/31 GR 1/30 N/A GR 1
PERIOO GR DAT*
87 11 24 YllAlt MO DAY P'AGIElO 01' 20
ti6lll-~~.!.. al _!:12_ ~<!
~ !. :=. ~.!~.
...V...:..~ !J ~
i r ~ __ _
4111111..,E~~q__ _____ -.
PO BOX 570 lOC
]-16)..
NJ0005622 11-19)
EJlpira 2-29-tu 486 P'lllllMIT. NUM.lllll DleCHAllGlt.. uMe&ll
.... ~-------------
.Jie.w.a.UJ~_Q_ll.Q..l_ ___________
MONITORING PERIOD ua,m~~~m__~~~ating~ta:.!_io~------
YllAR MO I DAY I YllAll I MO I DAY aaiATaC~~~A*l_!_~ay~~~ek_ ________
P'llOM 87. lo I 01 I TO 87 I lo I 31 (20-21) (ll-lJ) (l4-lJ)
(,6.,UJ (18-29) (JO-JI)
NOTE: Rud lnltnlcUone belof9 oomplellng lhll fOnL x
(J Ce1d O"'y>
QUANTITY Oil LOADING (4 c.,, Old)')
QUALITY Oil CONCllNTllATION PAllAMOllll (4'-JJ)
('4-41)
(JMJ)
(46-JJ)
(JUI)
NO. P'llllQUll.. CY
- AMP'Lll:
IP OP' TYPll
(.llJ7)
ANALYele AVllllAGll MAXIMUM UNITe MINIMUM
'AVllllAG&,
MAXIMUM UNIT*
U-'JJ (6441).
(611-7UJ 00400 l
eAMPLll 1f MllA*UllllM&NT 6.90 7.20 0
?.,/7 GR pH
~*
Effluent Gross P'.... IT 6.00 9 *. 00.
SU
- ~ :. 1/7 GR ll!IOUUl...... T I 00400 2
- AMPLll 2/7 GR MllA*UllllMllNT 7.00 7.40 l
pH Influent f'PMIT SU 1/7 GR llllOUlll&MllNT I
500.50 l
- AMP'LIE NA NA I
Flow MllA*URllMliNT NOTE 1 NOTE 1 Effluent Gross PUMIT MGD CONT NA llllOUlllUlllNT I
1 00340 l
llAMPLIE 1/31 GR l
COG MIEAllUREMIENT 200.00 200.00 Effluent Gross P'llllMIT MG/L 1/30 GR ll*QUlll&MllNT 00340 2
llJAMP'Lli" 1/31 GR COD MllA8UAIEMllNT
- i00.oo 180.00 Influent PllltMIT MG/L 1/30 GR IHSQUllllUl&NT 00340 4
- AMP'Lll 1/31 GR-COD MllA*UllllMllNT 20.00 20.00 0
Effluent Net NlllMIT MG/L l/3Q..(_;R llMUIUNllHT so.oo GR-50060 1
1
- AMP'Lli
<0.. 01 0.01 0
Chloaini, Total MllA*URliMIENT MG/L PE;R'IOD Resi ua, sws l"lllUllT 0.20
.l-Effluent Gross llllSQUlllllMllHT PERIOD GR NAlll&/TITL& PRINCIPAL UllCUTllllE OP'P'IClllll I ClllTIFY UNDUi l'lNALTY OF LAW T"AT I "A\\/[ f'[!UiO#<ALLY [KAM... [D T&LllPHONll DATll AND AM FAMILIAi!, WIT" T"[ INFO-ATIOH SU-TilD "[R[IN AND UKO
()/!...-:-r ~
J. Trejo Of< MY ltOQUIRY OF THOS[ 1N01111DUAUi 1-[0IA T[L V lllSP'ONSlllL[ FOii OBT..... lfOG T"[ ll'<FOltMA TIC>fo I llCLl[\\I[ T"[ SUllMITI[D INFOllMA TIOH Rad.Prot./Chem Mgr.
15 fRU[
ACCURATl A"D COMl"L[T[ I AM AWAR[ T"AT T"[ll[ AIK SIG "lflCANT l'U<ALTl[5 FOii SU... ITIING f'AL5[
1NfORMATIOfo l"CLUOING 609 j339-4399 87 11 24
. Ttt[ P0551111LITY CY fl.. [ AND IMl'ltlSO/llM[.. T stt 18 USC I 1001 AND elG~URll OP' PIUNCIPiJXllCUTIV&
ll u Si C t t 318 1Prnau.,. tlltllrr 111111,,.,.,,,.., 111ey *n'l~r /111u "I> '" 11u.1u1
~~~~I NUM.llll end.,,,...... mlllf'I tmp1t*u1utwnl u/ """"" ' *O,.IA* *"".\\,.,.,. '
. OP'f'ICllA OR AUTHOR I AG&NT YllAll MO DAY TYPllD Oil PlllNTllD COMMSNT AND PPt.ANATION OP' ANY VIOLATION8 (/l1/111nc ' ""..,,....,,,,..,.,,,.,,,
Discharge 486 is #23 condenser cooling water NOTE 1:
Flow data unavailable as of report date.
Data will be included with the November report.
~A for111 ~20.I (R*w 10.79),.111.v1ou* 11D1T10N TO..
- u*u>
UNTIL 8UPPLY 18 dHAU8T&D Cll&PLACll* &PA P'ORM T*40 WHICH MAY NOT*& ue&D.1 PAGEll o~o
... 11111n** NAM*/ADDRIE88 (111dw'*
l"<<llU>* N.-1Loco1lo11 ii dl[Jrn111).
NATIONAL... OLLUTANT Dl8CHAllQll llLIMINATION *Y.*T&M llVrur.*..,
DISCHARGE MONITORING REPORT (DAiii>
~Y-__ GEN...:.. M:iR._.:-_ENV..!.. A&.""F
- ______ -'-- ~ _
ADQ!!.Uf __
PSE&G ________________ _
--~-_!'...:...0...:... BOX 2].Q_._:J.OC __....:... _______ _
~----NEWARK ___ ~J~710~-------
u~m-~SALEM_GENERATINGS~TIOO _____ ~-
!aCAT.!2.tL._l.CMER_Al..UMAY..§_ CREEKS ________ _
FROM (1-161 486 P'l:RMIT NUM*l:R Dl*CHARG£ NUM*l!R MONITORING PERIOD YEAR I MO I DAY I I YEAR I MO I DAY 87 10 I 01 I TO
'97 I 10' I. 31 (20-ll I (12-lJl (14-lJ)
(lli.ti) Clll-29) {JO-JI)
NOTE: Reed ln1truclloM before c:omplatlng 1111 lonn~
x (J Cord Only)
QUANTITY OR LOADING (4 Cord Only)
PAllAMllT**
(46-JJ)
(J4-61)
(Jl-4J)
(Jl-J7)
AVIEllAQE MAXIMUM UNIT8 MINIMUM UNIT8 6l-6Jl (64~)
AVl:RAGI:
(6P.70) 00530 1
8AMPL*
- SOLIDS,
'l'Ol'AL.
Ml:A*UR*M*NT 467.50 2/31 267.75 SUSP~
PalUllT EFFWEm GROOS ll*QUlll*MKNT
- l/30 GR 00530 B
8AMP'LI:
- SOLIDS,
_'l'Ol'AL MEA8URl:MENT SUSPllIDED NllMIT D~LUENI' 11*QUlll1tM*HT 370.00 212.38 M3/L 2/31
- 1/30 GR
- GR 00530 4
- AMP'LE SOLIOO,. 'l'Ol'AL MEA*UREM.ENT 55.38 97.50
~/L 2 2/31.
SUSPENDED HllMIT I::'i:"llJENl'. NET R*QUlllSM *NT 30.00 45.00 **
- 1/30 GR u11"'~!
l 8AMPLE PETROLEUl4 HYDROC.AROONS*
MEA8UREMENT EFPlllEtn' GROSS Pall MIT RaQUIRl:MllNT 0.10..
1------+------+--*-o_
1...,o_-t. ~r;/L
- 1/31 GR 1/30
. ~-..
00551 B
8AMP'LE PETROLEUM H'.'DROCAROON MEA*UREMIENT 0.30 0.30 CR INFLUENl' P*lllMIT I
lllEQUUtaMl:NT GR 00551 4
9AMP'LE PETROLEUM HYDROCARBON MEA8UREMENT I
o.oo 0.00 GR EFPUJEtll' NET NllMIT 1t*QUlll*M*NT 50060 1
- AMPLE MEASUREMENT CllUh'UNE, TOl'AL RF.SIDlN.., ~
P*RMIT EFFWENl' GROSS llSQUIREM*NT N/A N/A 0.20 M:;fL' N/A
.GR
~-
- ?ERIOD GR
.NAM*ITITLI: P'lllNCIPAL l:Xl:CUTIVI: OFFICl:ll I Cl:ATlf'Y UND[A l'(NAL TY Of" LAW THAT I HAV[ PERSONALLY [KAMiNED ANO AM FAMILIAR WITH TH[ INFORMl'TION su11M1n[D H[ltt:IN AND llASlD ON M'f INQUIA'f or THOS[ INl)IVIOUALS *-[DIAT[L., RlSPONSlllL[ FOii OBTAINING TH[
INFOiRMUION I ll[Ll[V[ TH[ SUl!Mln[D INFORMATION IS TAU[
ACCURAT[ AND COM.. LCf[ I AM AWARE THAT TH[Af ARC.SIG NIFICANT P£NALTl[S FOR su-1n1NG FALS[
INFORMATION INCLUDING TH[ POSSlllJLIT'f or,.... [
AND IMPAISONM[NT su' 18 use ' 1001 AND.
l"JUSC
- 1]19 1Prnal1w* Ultllrr tltr* 1lalMIH "'*" 1nrludr /it.rm lip'".,,,.,,,.,
arad.,,,...,.,....,.. '"'P"*"""'""' uf lwt.....,.n << munllt* end*.-.,.,.,.'
TllL*PHON*
DAT K
.J. Trejo Radiation Prot./Olan. M;Jr *.
/}_p...
~<
~I/A 81G~Ulll: OF PRl.NCIPA/. jx~CUTIVI:
OP'FICEll OR AUTHDlllZ'fD AG.NT COMMl:NT AND l:XP'LANATION OF ANY VIOLATION8 !Rr/r,.11rr "" """'hmrnu llwrr)
- 7.day averaqe
- PA Form 3320*1 (Rew. I0-79)Plll:V1oua l:DITION To *IE UHD UNTIL 8UPPLY 18 1:XHAU8:rED CAllP'LACIH l:PA FORM T~40 WHICH MAY NOT.*1: U811D*I 609 1339-4399 87 11 24
- ~:I NUM*llll YKAll MO D... Y
..... H.. 11 5M.&,.A... 11./AMUft-... L4n&h*6'C' F.allly N-/L<<.U- *I dll-111J
~u;_G..,!.~ r a_!~~n age E-...:.~!!.Y ~~ff
~i r ~ __ _
~
PSE&G
~UUl----------------------
PO BOX 570 lOC Newark NJ 07101
~~m_S~~~~~..!.~tinLS~ti~------
T Lower Alloways Cre*k
~t1211...--------------------
DISCHARGE MONITORING REPORT (DMft) tJ*llll 17-IPJ NJ0005622 481-483 PllllMIT NUM*&R Pl*CHA.lllGli: NUM*ii:ll MONITORING PERIOD Y&All MO I DAY I Y&All I MO -[ DAY P'ROM 87 10 I 01 I TO 87 I 10 J 31 DMB Nu. 2040-00i.*4 EKpira 2-2~84 (20-21)
(22-lJ) (14-lJ)
(l6*ll) (28-lP) (JIJ.JI)
NOTE: Ruel 1n11n1ct1one........ COlllpledng 1ta1m lonn.
x (J CMd 0..Jy)
QUANTITY OR LOADING (4 Card 011lyJ QUALITY OR CONC&NTRATION PA*AMllTU (46-JJ)
(J4*1>
(J,-4JJ (46-.SJJ (JUJ)
NO. P"ll&QUllNCY
- AMP'L~
OP" TYPll (UJ7)
ANALY81*
AVllllAQll MAXIMUM UNITe MINIMUM AVllRAQll MAXIMUM.
UNITe 6J-4lJ (64.,,
(69-7111 00010 2
eAMPLll CONT NA M&AeUllUl&NT NOTE 1 NOTE 1 Temp Deg Centigrad Influent P&llMIT
. ~ :'.,-;***.
. ~: *'
DEG.C
.~ :* CON'l'
- NA
- 11CW**...... T 00010 1
eAMPLll CONT NA Temp Deg Centigrad
~ MllAeURllM&NT NOTE 1 NOTE 1 Effluent Gross NllMIT 4 3 ~ 30:
DEG.C
- ~
CONT NA1 11aou1a... 11HT 00016 4
- AMP'LIE CALC NA MliA*URllMllNT NOTE 1 NOTE 1 Temp Difference i
Effluent N~t
...... IT lllllctU*llDlllNT 15.30 DEG~C
- CONT NA
- AMP'LIE MllA*URIE.MllNT P&RMIT R&QUlaUllNT
- AMP'Lll MllA*URllMllNT
... llMIT 1154HU.PlllNT
- AMP'LE MllA*URllMllNT l'UMIT JI
- AMP'LE ME:AeUllEMllNT PIUU11llT R*Ut*DllllNT
' iNAM*ITITLll NINCIPAL U&CUTIVE Ol'l'IC&R I CillTIFY UNl>V' PCNALTY Of' LAW THAT I HAV[ l'Clt50NALLY [KAMINCP T&LU'HONa DAT*
ANO AM f"AMILIAll WITH TH[ -OllNATION ~U-TI[P HCRt:IN AHP 8A6lP
<fa p -----.
ON MY llWQUIAY OF THOtiC 1NDIVIPUAL6 -[DIAULY ll[lil'ON518Lli: FOii
( 609)
J.Trejo 09TAINWG TH[ INFORMATION I KLllVE THC su... 1n1:0 INf"PllMATION
- ,,,v-~ { ~
IS TRUC ACCUllAT[ ANO COMl"L.£T[ I AM AWAll[ THAT THUi[ All[ 51G Rad.Prot./Chem Mgr.
Nlf"oCANT l'CNALTICS FOii 5U.. ITIING f"AL6[
INf"ORMATIOH INCLUDING 339 I 4349 87 11 24
.TH[ ITY OF flN[ ANO *-~MINT SI:[ lill use t 1001 ANO e1~
1 UR& OP' PrllNCIP'AL:t~-CUTIY&
Jl ur.c
- u111 1hulrt1* Mltllrr,.,.,.,.,..,,.. **~ 1nrludr futH 11111 1u llu.U1*1
~!!21 TYP&D OR PRINT&D
- Ml or,....,,,..,,...,,.,,,..,,,.,..,.nl u/,.,..,...,.,. I.au111A* ellfl !i WWII I l'ICER Ori AUTHORI:&&
Q&NT NUMallll YllAR MO DAY I
,.OIHl*NT AND UPLANATION 0 I' ANY VIOLATION* (/C*l*HM* ""llllM&h-1111,..,.)
481-483 is Unit #1 condenser thermal monitoring data.
NOTE 1:
Thermal data is unavailable as of report date.
Data will be included with the November report.
A f** UZO-l (Rn I0-7t)PR&v1ou* &DITION TO** u*&D UNTIL *UPPLY le UHAUeTSD (RQILAC&e U'A P'ORM T*40 WHICH MAY NOT_*& U*llD.I
11 11 I
,...... ITY*&.. AM*/AUMft&** "11"*
,..,,,,,, "_,,__.,.,, ~,,_,,,,
- i4U.:_G_!.~!_a_!_~~nage£.-=.~~~~ff~ir~ _ _:__
Dl8CHARGE MONITORING Rll.. ORT cVMICJ J./01 17-111)
~U.Ul_PS.!_&G _________________ _
NJ0005622 PO BOX 570 lOC P'ltRMIT NUM*IER DleCHAllGt. NUM*t:ll
r-----------
Newark NJ 0710 MONITORING
~~m_:_Salem Generating Station_=====
PERIOD YIEAR MO I DAY I Y*AR I MO. I DAY
.QWJRIL.~~~~~~~y~~~~--------
P'ROM OMIJ Nu. 204{HJU< *4
- Expira 2-29-84 87 10 I 01 I TO 87 I 10 I 31 NOTE: Reed aftauucllone Mlof9 00111Plellng lllJe 1onn:
(20-211 (22-lJ) (l4*lJ)
(l6*l1) (211-211) (JO.JI)
IX (J C111d 011/)')
QUANTITY OR LOADING (4 Card 011/)')
QUALITY OR C:ONC:*NTRATION PAaAMP&a (46-J:JJ (J4-6/)
(Jlt-4JJ (46-jJ)
(JUI)
NO, P"ll&QUINCY eAMP'LE u
OP" TYP'&
(.IJ.,17)
ANALY*le AV*RAClll MAXIMUM UNITe MINIMUM AV*RAClll MAxlMUM UNITe 62~1 (CM-61J (6Sl-7UJ 00010 2
eAMP'Lll CONT NA M*AeUR... *NT NOTE 1 NOTE 1 Temp Deg Centigrad*
~_);/.*
I.. :*:. '
Influent P&MllT DEG.C..,.. r CONT
- NA 00010 l*
eAMP'L&
1 CONT NA MIEA*UR*W*NT NOTE NOTE 1 Temp Deg Centigrad*
Effluent Gross NRWIT R&OUl.... llHT 43.30 DEG.C
- CONT N~
00016 4
- AMP'LIE CALC NA MIEAeURllMIENT NOTE 1 NOTE 1 Temp Difference Effluent Net PPMIT "114"1,........,.
is. io DEG.,C
- CONT N~
I
- AMP'LIE M&A*URIEMIENT
... llMIT 11qu1a... &NT liAMP'LIE M IEA*U RIEM ltNT
.. allMIT 11sau1*P1*NT
- AMP'LIE MEA*URIEMIENT.
raJIMIT
"*caunt&M.,.T
- AMPLE MEA*URIEMENT PIUUHT llir.QU IRUI llHT 1i1.-an1TL* p111Nc:1PAL 1:x11c:uT1vi.: of'P1c:1:R I CLRTIFT u.. Dlll. !'£NALTY Of" LAW THAT I HAV[ l'[flSO.. ALLY [llAMINCD T*LUHONll DAT I[.
A..0 AM FAMILIAR WITH THC 1.. FQRMATION ~-ITICD H[ll[IN AND 9A6CD
~
ON MY INQUIRY or THOSC INDIVIDUALS 1-CDIATELT llCSl'ONSlllL[ FOii J.Trejo OllTAl,.ING THC
,..,OllMATION I NLllVC THC SU-TilD INFORMATION I~
(609)
IS TllU[
ACCUllAT[ AND COM~£T[ I AM AWAllC THAT THUi[ All[ SIG Rad.Prot./Chem Mgr.
NlftCA~T P£NALTl[S FOR SU... ITIING FALSC INFORMATION INCLUDING
- 1001 AND 13 u !tC
- I :111t 1P*1W1llwa,.,.,,,, IAtw 1l*lldlit* "'*)' 111rludr /11tn up '" llCJ.11111
~!!~I TYP'ltD 011 P'RINTllD aiwl.,, f'IN.I*"'""' '"'~t19"'llmrnl u/,.,,,_,.,.,. I *u,.1111* a11d.i.,,..,. 1
- f'f'ICIER OR AUTHORl:Z AGaNT NUM*llll Y*All MO DAY
.QMWl[NT AND U~LANATION 0 f' ANY VIOLATION*.!IC*/*r*rtCI "" """c/Un*lll* Mr*)
484-486 is Unit #2 cDndenser thermal. monitoring data.
NOTE 1:
Thermal data nnavailable as of report date.
Data will be included with the November report.
A Fe,. U2*1 (Rew t*79)"'u1v1ou* *DITION To *11: u*&D UNTIL *UP'P'LY le llXHAUeT*D (RllPLAC:ll* ltP'A P'ORN T*40 WHICH MAY NOT ** uellD*I
..AGE14 OP'20
P'll:RMITTEll: NAMll:/ADDIH8* (/11dude FacilllJ N11m.* /Luc111io11 I/ dll/err..I)
NATIONAL P'OLLUTANT Dl*CHARGll: ll:LIMINATiON *Y*TllM (Nl'DES)
DISCHARGE MONITORING REPORT (DAIR)
(1-161 11*19)
NJ0005622
~ME ___
GEN~?Gl*~-ENV~AFF*-----~--~
ADDRll:H PSE&G
l>.O:-oox"S70--Ec---~-~---
Dl*CHAlllGE NUM*Elll P'PMIT NUM*IER
NE.WAW<-----ro-01w1------
. u~lll= SALEM GENERATING STATION=~
..=====
LOC,.AT.. !!;!,l'L.,_W'lER_ALLCloJAY§_ CREE.JS_ ___. _____ _
MONITORING PERIOD YEAR MO I DAY I I Yll:Al'I I MO I DAY 87 10 I 01 I TO 87 I 10 I 31 P'ROM Fann A""""'9d OMB No. 20fO..(}()(Jlf Expirei 2*29-84 (10-ll) (Zl-lJ) (l4-lJ)
(l6'l7) (11-19) (JO-JI)
NOTE: Rud lnatruc:llonl befOlw compleUng.. Iona.
PAl'IAMll:Tll:R (J2.. J7) 00015 4
HEAT I MILLIONS OF B1'U PER HOUR NET_
EFFLUEm' NEI'.
- AMPLll MIEA*Ul'll:Ml:NT H~MtT *.
l'll:QUIMl... llNT.
- AMP'LE MEA*UREMll:NT Pl:l'IMIT l'lllQUIREMl:NT SAMPLE Mf:ASUREMENT*
Pl:ltMIT RICQUll'lll:Ml:NT
.SAMPLE MEASUREMENT PIERMIT RllOUIRll:Ml:NT llAMPLE MEASUREMENT
... RMIT IHQUUlaMSNT SAMPLE MEASUREMENT
- HltMIT l'lll:QUIRl:Ml:NT SAMP'LE MEASUREMENT
. ** PlRMIT l'llEQUll'IEMll:MT
- NAME/TITLE PRINCIP'AL EXECUTIVE: OFP'ICER
.J. Trejo (J C11*d Onlr)
QUANTITY OR LOADING (46-JJ)
(J4-6/)
AVERAGE MAXIMUM UNIT8 (4 C11rd Onlr)
(Jl-4J)
MINIMUM NOTE 1
- J..":... "
/-.
NOTE 1 TllLllPNONa CAIC NA
- ~
" ***=*
- -"~*:
-~* *=.... :... :*
-~
DAT a Radiation Prot./Chan. M:Jr.
I CERTIFY UNDER P'[NALTY Of' LAW THAT I HAVE PERSONALLY EllAMllUD ANO AM FAMILIAR WITH THE INFORMATION SOllMITTED HCllEIN AND llASED *
- ON MY INQUIRY OF THOSE INDIVIDUALS 1-EDIATELY AESPONSlllLE FOlll OBTAINING THE INFORMATION I
llEi.IEVE TH[ SUllMITTED INFORMATION 15 TAU[
ACCURATE.ANO COMl'l£TE I AM AWARE THAT THERE AA[. SIG*
NIFICANT PENALTl(S FOR SUBMITTING F:ALSE INFOlllMATION INCLUDING TH[ POSSIBILITY Of' f'IN[ ANO IMPlllSONMENT SEE Ill use I 1001 ANO 3l LI.SC I 1319 rfrnal11r1 urtdrr tlerw 1fel&dr1 "88)' 11trlll!llt f11tr1 "ll"IU llUJMIU ond or "'a.zr"'um unpnl4H1n1rnl of hrlu..,.,,n fi mnnlh* *and S yrar1.I
- ~PURE OP' PRINCIPA,i. llXllCUTIYll r-6in0m9n'rl'l-3-3_9_-_4_3_9_9-i_8_7-+_1_1-+_2_4--f
. VFF'ICE:R OR AUTHOIUUD ACll:NT
- !'!I NUM*&R YllAR 110 DAY COMMENT AND EXPLANATION OF.ANY VIOLATIONS !Rr/,,rnt'r ull ullut'hmrnu h,,r)
FAC IS STATION HEAT RELEASE NOTE 1:
Thermal data unava.ilable as of report date.
Data will be included with the November report.
EPA Form 3320*1 IRev. 10*79)P'R11V1ou~_ED~T!':?N_."!'~.~'= UBED CREPLACI!* EPA P'ORM T*40. WHICH MAY NOT *IE U*E:D.)
~AGE }SOP'2Q
NATIONAL POLLUTANT. Dl8CHAltGa aLIMINATION 8Y8TKM tNl'DES)
DISCHARGE MONITORING REPORT (DMIC)
(1-16) 11-19 NJ0005622 48C l"altMIT NUM*alt Dl*CHARGlt NUM*IR MONITORING PERIOD YltAR
_MO I DAY I FROM Fann A/IPfrwed
. OMB No. 20fO.<<JOtl ExpitW 2-2944 87 10 I 01 I TO (20-21)
(ZZ-Z.J) (24-2J)
Y*Alt I MO I DAY 01 I lo I 31 (26*27) Cllf-2!1) (JO-JI)
- NOTE: Rwl lnatrucdonl betol9................
l"AltAMaTalt (J2-J7)
X t-
<_J_c_o_*d_o_"...
'Jl_)_Q_U_AT"""N_T_IT_v_o_R_Lo_A_D_IN"TG----v-'-'_c_o_rd_o_n_*'_'_~TQ_U_A_L_l_T_v_o_"_'.c_o_N_CTIE_N_T_"_A..;..T_l_O-'N----------t
('6-JJ)
(J.f-61)
(JMJ)
(46-JJ)
("41)
NO. P'RS~:NCY eAMP'L*
llX ANALY*I*
TYP*
AVERAGE MAXIMUM UNIT8 MINIMUM AVIEltAGIE MAXIMUM UNIT8 62-.. JJ
('441)
(6f..70) 00530 1
8AMP'La
- SOLIDS, TOI'AL MEA8Ult1EMaNT SUSPENDED NlllNIT" EFFLUENl' GROSS lllEQUlltllMKNT 00010 1
- AMP'LI:
TF.MPERATURE M1tA*U1t1EMIENT DEG. CENTIGRADE.
NllMIT EFFI1JENT GROSS RIQUlltl:MSNT 00551*
1
- AMP'LE PETnOLEUM MEA*UREMENT HYD~S NltMlT EFFLUENl' GROSS ltSQUlltSMINT 01042 1
8AMP'LE
'roTAL MEAllUREMENT (A5 CU)
P'IElllMIT EFFLUENr GROSS ltlEQUIR... SNT 01045 1
llAMP'LIE
- IRCN,
'I'(]WAL MEA*UREMIENT (AS FE) l"SRMl1' EFFLUENl' GOOSS ltEQUIRPll:NT 50050 1
BAMP'LE FUM MEASUREMENT
- ,._..MIT EFFLUENT GROOS lllQUlltllM*HT 00610 1
9AMP'LE
~
MEAllUREMENT
( A5 N)
- . PtRMl1' EFFLUENT GlnC:S ltlEQUlltaMaN'Y
. :.~* \\':'(.,:.:
NAME/TITLE PRINCIP'AL IEXIECUTIVE OFFICER I CERTIFY UNDCR P£NALTY OF LAW THAT I HAVE ~E"50NALLY EKAMINED ANO AM f"AMILIAR WITH THE INFORMATION SU-TT[O H[lll£1N ANO llASED ON MY INQUIRY OF THOS[ INDIVIDUALS 1-[CllATELY 111£5PONSlllL[ FOii OBTAINING THC INFOllMATION I IS[LICVC THE SUISMITTCD INFORMATION IS TRUE ACCURATC AND COMl'L[T[ I AM AWARE THAT THCRC AA[ SIG*
NIFICANT P£NALTIC5 FOR SU-OTTING FALS[
INFORMATION.
INCLUDING TH[ POSSllllLITY OF FIN[ AND IMPRISONMENT 5(( '" use I IDOi AND 33 use' I ]t9 IPr111dl1H undr,,,,,., ***tulH....,. lnrlwlr,.,...,.,, lu "*"'"'
artd" m*.umum 1mpr11<mn1rnf u/ hrtuwn 6 monlll* *nd."i.\\*Hr*.I J. Trejo Radiation Prot./Chem. M;Jr.
TYP'ED Olt l"RINTaD COMMENT AND EXPLANATION OF ANY VIOLATIONll (R*/*,,ric*r a/I a11uchm*n1J h"*)
48C is Non Radiological waste treatment 17.50 Jo.no 18.20
- f:
0.15 16.oo' 0.22 26.00 8IGN/_,{,R1t OP' P'ltlNCll" O~ICER OR AUTHOIU I REP'LACI* IEfiA FORM T*40 WHICH MAY NOT *IE U8ED. I 26.00
- </?\\
. z.K;/L 100 :..:;.;.':{*
- llll***'*.,::,**<*'***
20.00
~t*::<:\\::::1::*::;,:.
.. DEG. c 0.40 34.00 TaLIEl"HONI:
0 2/31
- . **~::}::::: ?:/:':' **..
... :2130
- ,10/31
- 1*:-:n.***
lll""r~Y 0
2/31 0
2/31
- :2/J(L.::*
0
- 2;31 0
2/31
- .::::.. ::.::*.. ::.. ~;:*:~...
.::::::-=:~*:.. *:**
- 2/3()'(.
24HC f'f::,*
- ;<;?..
(
24HC GRAB GR 24HC
.:.*;,y*'f:*
- 24oc 24HC GR DATS 609 1339-4399 ltXIECUTIVlt D AGltHT t--rm:!.-~!-ilr--N-U-M-.-.-..
--+-Y-IEA-11-1--11-0-.f.-D-A-Y-I 87 11 24
PIE"MITTIEE NAMIE/ADD"U* (lnd11de Focillo* Nam~/Loca1ion i/ dlOennl)
NATIONAL POLLUTANT Dl*CHARGE ELIMINATION livn*M (Nl'DESJ
. DISCHARGE MONITORING REPORT (DAiii)
~y ___
GEN~KiR*~-ENV~AFF. ________ _
(1-16) 17-19)
~~~-J~&q_ _______________ _
NJOO 5622 48C
____ J~~OOX57Q_ __ l~---------
PIERMIT NUM*IER Dl8CHAllGE NUM*U*
NEWARi< _______________ _
U~ID-~ALEM_GENERATrnG~~IO!!_ ______ _
~T.!.2.fL_lil-lER_~ CREEK --- ___ _;._ -
P'ROM Yl:AR MO I DAY I YEAR I MO I DAY MONITORING PERIOD
- Form AfJPl'OWd OMB No. 20ifO.()(JOil Expiiw 2-29-IU 87 10 I 01 I TO 87.I 10 I 31
<20-ll > 122-2J> <2'-lJ)
""<""t2""6*
.. 21
"'.>,.....,1"'2a"".* z~ll~>........,;<J""o;;;.J~1-'>
NOTE: R*ad lnllruc:tloM b9fore ~
.... tonn.
P'ARAMITIE*
(J2-J7)
X (J Card Only)
QUANTITY OR LOADING (4 Gard Only)
QUALITY Oil.(:ONCIENTRATION 1-__
(~46_-_,_J_> __
-.-----~-'->---.-----t---<-J_a~_,_, ___ _, ___
<_,_~_,~J) ___ _, ___
,~~.;..,;;,;*~)---.------fNO. ~**o~:NCY llX ANALY*I*
AVl:RAGIE MAXIMUM UNIT*
MINIMUM AYltRAGIE MAXIMUM UNIQ ISJ-6Jl (H41) 01092 1
EFFI1JENI' GROSS 001032
. 1
- ana-nUM-HEXAVALENT 00340 1
CHEMICAL OXYGEN DEMAND 00400 1
Fil ( Compl :it.a nee EFFLUENT 00400
?I CI::AmF!ER EFF
- 99004 pt.)
TOXICITY BIOASSAY IC-50 (96-HR) (M.bahia)
- AMPLI MEA*UAEMIENT P'l[RNIT RIEQUl.SMINT llAMPLlt MEA*UREMENT N*MIT REQUlflltM*NT SAMPLE MEASUREMENT NRMIT RltQUIR*MINT
.* AMPLE MEAllUREMENT
.... MIT RCQUUt*M*HT
- AMPLE MEAlllUREMENT
... AMIT
- SOUIR*MINT SAMPLE MEASUREMENT
- ..UMIT RIQUIR*M*HT SAMPLE MEASUREMENT t"*RMIT ltlEQU I RltM INT NAME/TITLE PRINCIPAL l!Xll:CUTIVI! OFP'ICl!R J. Trejo 6.30 6.00 8.90
>100.00
)*'.:*
- ~so* ***. :*.,.*
- '\\<::,
T<? *.
<0.05
<0.05 7.40 SU 12.10 SU
'***:*.?
~
~
EFF.
- ~.):. i!'...:.
BY VOL
- TILEP'HON*
0
?/31 24HC
,, ~. *;-.
~~-..,
.:.'.: :*~/30.
24Hc*
0
~/31 24H
. :* :**::~ ;*
- 1". '2/30 24HC 0
0 0
24HC 2/31
- 2:4HC..
36/31 GR NA GR l/QTR 6HC
- '*.. :*/*:
=:~*.1!.*.
DATI Radiation Prot./Chan *.M:Jr.
I CIEATlf"Y UNDER PCNALTY OF" LAW THAT I HAVE n"50NALLY EXAMINED AM> AM FAMILIAR WITH THE INF"O-ATION SUllMITTEO HEMIN ANO BASED ON MY INQUIRY Of" THOSE INDIVIDUALS IMMEOIATEL V MS~SlllLIE FOR OBTAINING TH[
INFORMATION I
BELIEVE THE SUBMITTED INF"ORMATION IS TRUE ACCURATE ANO COMPL£TE I AM AWARE THAT THt:RE ARIE SIG*
NIFICANT P£NALTl[S FOR SU-ITTING FALSE INFORMATION INCLUDING TH[ POSSIBILITY OF FINE AND IMPRISONMENT sec 18 use I 1001 ANO J 3 USC t I J I 9 t Prnol11r* undrr tltteir 1lolulr1,..., 1nrlwlr /rnr1 MP '" 1111.111111 arad or ma.11mMm 1mpr1-t1t1nll'nr u/,.,.,.,..,,. 6 mnnflt* and S :iirorJ11 I
- aNJJ6RE OP' PRINCIPA
~ucuT1v1: G09 I 339-4399 oW.cER. OR AUTHORI El AGl:NT
,.~~~,..,,~:-Ir---. N-U-.. -.-lt-.. --t-Y-llA-..
--1"--.. +-D-A_Y_,
87 11 24 TYPED OR PRINTIED COMMENT AND EXPLANATION OF ANY VIOLATIONS (Rr/errnrr all ullu**hmrnlJ llrrr)
Bioassay started 10/26/87.
Completed 10/30/87.
(Rl!PLACIE* IEPA P'OR.M T*40 WHICH MAY NOT *11: U*ED.)
P'AGE 1701"20
PlllUUTTllll NAMll/ADDIH** cl11c/ud.
FecoMIJ N-/LOC9llo11 I/ dj//*nral)
GEN MGR ENV AFF NATIONAL P'OLLUTANT Dl*CHARQll llLIMINATION *Y*T&M ll'll'UC~J DISCHARGE MONITORING,REPORT (DAiil)
~g----~-~---~-~--~------
(1-16)
(17-19)
~aw_JSE&G _________________ I NJQQQ5fi22 I I
487
---~J-0~~57~ __ 10~---------
Pll"MIT NUM*llR lo**cHAlllGI: NUN*llA
~-----W-01J.UL ______
MONITORING*
PERIOD uam __
SAIF.M_GENERATIN~S~TIOO ________
YllAll MO I DAY I YllAll I MO I DAY FROM
- U**** rr-tr'P""*-<1--
OMB No. 20tf().()(J()4 EJtpi,., 2-29-84.
J:.:2C.ATJ2f!__IGJER _ALI:a-lAYS_ CREEK ____ -
~
87 lo I 01 I TO 01 I 10 I 31 (20-21) (21-lJ) (l4*lJ).
(1611) 1211-211) (JO-JI)
NOTE: Ruel 1natrudon. before completlng.. Iona.
!X (J Cerd 011bJ QUANTITY OR LOADING
,, c.ard 011lr)
QUALITY OA CONCl:NT"ATION PA"AMl:Tll*
(46-JJ)
"'""')
(Jl-4J)
(46-JJ)'*
(JUI)
NO. l"llllOUllNCY *AMPL*
01" (Jl.J7)
IP ANA&.Y*I*
TYP*
AVERAGE MAXIMUM UNIT*
MINIMUM
- AVllllAGE MAXIMUM UNIT*
61-4JJ 16UI)
<*9-70)
UU!:>JU
- l.
- AMP'Lll SOLIDS, TOrAL MllA*UllllMllNT 2.25 2.50 0
2/31 GR SlEPENDED
~/L "llllMIT EFFLUENT GRa>S llllQUllll:MllNT 30.00 **
100.00
- "1/30 GR 00390 1
- AMP'LE MEA*UAEMllNT
<10.00
<10.00 0
2/31 GR __
~/L N"MIT EFFllJENT GROOS llllQUl"llMllNT 100.00
- 1/30 GR 00551 1
- AMP'LE MULTI MEA&UREMENT 0.25 0.30 0
2/31 PE'IIDIEUM
~/L
- GR.
MOLT HYDIDCARBONS P'llltMIT R1"1<'T JJRNT ~~
llllQUllll:MllNT 10.00 15.0Q
- 1/30 GRi 50050 1
- AMP'LIE MIE:A*UREMENT NOTE 1 NCfrE 1 NOI'E 1 F.LCM
!D)
.. llllMIT EFFWENT GROSS llllQUlllEMllNT
- 1/30 GR 00010 1
- AMP'LE TF.MPERATURE~TER MEA*UREMENT 18.50 19.00 0
- {/~l GR DEG. CENTRI E
DEG.C EFFllJENT GRCSS
.. llllMIT
- 1/30 GR llEQUlllllMllNT
~n.oo 00400 1
- AMP'LE 0
- l/31 MEA8UREMENT 6.80 6.90 GR pl SU
~*
- NlllllT EFFllJENT GROOS RllQUllll:MaNT 6~00 9.no 1/10
- AM.. LIE MIE:A*URIE:MIENT
.. SllMIT lllEQUlllSMSNT I C[ATlf"Y UNO£.. ~"AL TY Of' LAW THAT I HAV[.. [llSO"ALLY E*ANIN(D NAMS/TITLIE P'lllNCIP'AL EXECUTIVll OFFICER ANO AN FAMILIAlll WITH TH( INl"ClllMATl()N SU-TT[D H[ltUN A"D.... 51:0 (JJ!-¥ TllLllPHONll DATS ON NY INQUIRY Df' THOS[ l"DIVIDUALS INMCDIATCLY R£5"0N51llL[ f"OA J. Trejo OBTAINING THC lNf'OAMATION I lll:L.l[V[
THC SU-ITT[O INFOltNATION
/T... -
I 15 TAU(
ACCUlllAT( AND CONf'LCTll I AN AWAll[ THAT THCR( AR( SIG Radiation Prot./Chem. l-tJr.
NIFICANT PC.. ALTl[S f'Oll SUBMITTING f"ALSl INFOANATION INCLUDING I
TH[ POSSllllLITY Of'.Fl"[ AND *-~MCNT SU II USC I 1001 AND elG"TUllE OF P'lllNCl"ei l:XllCUTIVll 609 339-4399 87 11 24 31 use 't319 *hrwllw1 11ttd,, 11&1w,,.,.,,,,,...,. uerllldr 111111..,, 11u.***1 TYPED 0" P'"INTllD
- wl 01 ma.1111u1111 1mpr1K111.mrnf u/ #Wf&1Wfl ' *nnrA* end *',,.,. I OFFICER Oil AUTHO"IZIED AGlllNT
- I NUM*ll" YllAR
- MO DAY COMMIENT AND UPLANATION OP' ANY VIOLATION* CRr/*""'* ull u11uch111*11l1 ll*r*)
Note 1
Phvsical m:xlificati.on required in order to obtain data. -
487 is the HHB yard drain 45 m:J/l as a 7 day ave.
Clll:P'LACU E.. A FOAM T*40 WHICH MAY NOT *E U*ED.)
PAGI: 18 OP'2 0
P'EllMl'!'Tltlt NAMlt/ADDllUe (l11dud*
Facillly Nam* 1Loca1lo11 If dl6*nlll)
NATIONAL POLLUTANT DleCHAllGlt l:LIMINATION *YllTl:M (Nl'DE.SJ Dl.SCHARGE MONITORING REPORT <Dlllll)
~g ___
GEN~M3R._:-_ENV~AFF*----~----
(1-/6) 17-19)
~~~-_J?~&~----------------
NJOQ05622 87A
_j>.~JPX2~ __ 10C ________ _
P'l:llMIT NUM*l:R Dl8CHAllGE NUM81lll
~ _____ l'U_.Q]lO..!_ __. ___ _
MONITORING PERIOD Yl:AR MO I DAY I I Yl:AR I MO I DAY FROM form APPIOWd OMB No. 20fO.OOtH Exp;,. 2*29414 -
u~~--SAUM_GENERATING~~roo __ ~---
.!:2~T..!2'L-:u:MER_ALI.a'JAYS CREEK --- __,. - -- -
87 10 I 01 I TO 87 I 10 I 31 (20-21)
(22-2J) (2'-2S)
(lfl.;lf) (23-211) (JU-JI)
NOTE: Rnd lnalr'Ucllon9 before completlng 1111 Iona.
QUALITY OR "CONCENTllATION PAllAMl:TE*
(J2-J7)
X (J Card 011!)')
QUANTITY OR LOADING (4 Card 011/)')
1----<-46_-_,J~>---,.---'(--~-'~>---,---~t-~-'-J~--~>_....... ~~~.;._..;_;..__-T_~~..;.;.~~
...... ---~
(46-JJ)
("41)
NO.
llX P'llllOUENCY *AM"-*
OP' TYfl*
ANALY818 I.
00056 1
Fia-1 RATE*
EFFLUENT GROSS 00310 1
OOD, 5-DAY EFFLUENT GROSS 00530 1
SOLIDS I TOI'AL SUSPENDED "EF'Fil1ENT GlnSS 74055 1
CDLIFOBM-FECAL EFFLUENl' GROSS 00556 Oil & GreaSe Effluent Gross 00400 l
?I EFFLUENT GIOJS 1
- AMPLE MEA*UllEMENT
.. ~...,.
llEQUllllllDllllNt
- AMPLE MEASUREMl:NT l"SJllMIT lllltQUIREMENT SAMPLE MEASUREMENT flEllMIT lll:QUUlllM*NT
- AMPLE.
MEASUREMENT P'l:RMIT Rl:QUUlllM*HT SAMPLE MEA&UREMENT fl*RMIT lllEQUIRIEMllNT SAMPLE MEASUREMENT
- NltllUT ftl:QUIRllM8NT SAMPLE
- MEASUREMENT*
- l"alUlllT ltlEQU 1 lllDl ltNT AVEllAGE MAXIMUM*
UNIT*
MINIMUM AVEllAGI:
MAXIMUM UNIT9
,U-4Jl (U-61)
<*9-70>
73.60 1.68
>87.50%
0.97 8146.94 NOTE 71.50 10.25
- .~/
3o.nn**
13988.00
.*.. '/ -,: *z:::IW:n;,,r:r *****
GPD
... ' *... ~...,*.*>*******,***.*-<":
~/L 32.80 M3/L 0
3~/31 GR
- *;OAJ:r.y GR*
2 2/31 GR
- ;1./30*
GR 0
8/31 24HC'
- .~:~~"/~:*.....
~*:*:
't*
- ~1~ri.
<4.00
<4.00 O
1/31 GR 2~6 Iri~'... <;.*
- ~-~~ *1tifi'l.. ~);~~*'*;* N/lOOMl' -~* : : ~~~ri:. > l"'d;; ~ :
<5. 00
<5. 00 M3/L
- '"°. " * :- : r{ *
- .;~:}:,¥ *
.... l0.00 0
1/31 Ga
.;Y.*~:.::.. :**.;::.....
- 1/30 GR
"""'""':~<i'":'!",.~,
.. ~.,,,,,~\\~*:.: *. =
... :.~*,y"'"!'.,_~_.*
- . _;_**.~.>_*:~'.'_.~. ;-.rl/{. ~.!"l!".'-.,,;.,~
..,,.... ~
.. ;... ~
...... ~**;:.::.. ~::****!'!"f. SU
- 6.*oo ** ; : *, *
<< ~:oo' *,*.
6.90 7.60 0
22/31 GR
- r..
- .. lf 30 GR GR
. *:"°*
GR NAME/TITLE PRINCIPAL EXECUTIVI: OFFICER I CERTIFY UNDER PCNAL TY Of" LAW THAT I HAY[ P'EllSONALLY EXAMINED ANO AM FAMILIAR WITH TH[ INFORMATION SUBMITTED H[ll£1N. AND llASED ON MY.INQUIRY Of" THOSE INDIVIDUALS IMMEDIATELY llESl'ONSlllL[ FOR OBTAINING TH[
l.. f"OAMATION I llELl[V[ THE SUllMITT[O INFDllMATION IS TAU[
ACCURATE A.. D COMPLETE I AM AWARE THAT THERE AR£ SIG*
.. IFICANT PCNAL TIES FOR SU-ITTING FALSE INFORMATION.
INCLUDING THE POSSIBILITY OF Fl.. f AND IMPRISONMENT SEE 18 USC I 1001 AND
)) USC' 1319 tf'~na/lw* MNirr llt~W 11*1,.ltli me,- l11rludr /lftrl fJp Ill lltl.llflfl oud or rruuuna.m 1mprumnntrnt of INit&*Wn 6 ll'lanllt* and.~.'¥Hrtt. I
(")_ p -
>~~;;-
Tl:LltP'HONlt DAT*
TYPED OR P'RINTIED 87 11 24 Yl:All MO DAY J. Trejo Radiation Prot./Chan. M:Jr.
/7- - --
(
609 1339-4399
- IG'"'URE OF PIUNCIP'~JEXECUTIVI: t-r-'r""!-*--* __ _,1---J---1--~
. d.l,;1CER OR AUTHOR~D A~ENT
. ~~~ I NUM*I" COMMENT AND EXPLANATION OF ANY VIOLATIONS (Rr/rrrncr all allachmrnu hrrr)
Note -BOD Avg. quantity oolumn represents % reduction.
- - 45 11B/l as a 7 day ave.
487A is tne Sewage Treatment plant NOTE - Avg. flow limitation = 0.20 MGD EPA Form 3320-1 IRev. 10-79\\ PRllVIOUe l:DITION TO 1111!: USED (Rl:P'LACU E:PA. P'ORM T*40 WHICH MAY NOT *E uel:D.J
~AGEJ. 9 01"2 0
l"tlt*un&& NAM&/ADDRUe (lllc/N"I F<<""11 N-/~lotl i/ tll/lnHI)
NATIONAL P'OLLUTAN*T tlleCHARGll &LIMINATION *Y*T&M '"'rue.a)
DISC.HAAGE MOllUTORING REPORT (DAIR)
~g __ _§EN~~*~.l;NV~AFF~~~-------
~U~-J>SE&G ________________ _
0
.,6,.17-111) ruo 05622
-~--~~~00~57~ __ 10~~--------
l"<MIT NUlla&i.i DleCHAllGll NUM*llll
--~-~-----W-~~L---~--
MONITORING PERIOD UC&Urlll
....sAiiEM ~Sl'A'llON ------
YllAR MO I DAY I YllAlt I MO I DAY f:QQ.~~-UH:R~~CREEK---~------
FROM 87 10 I 01 87 10 31 I WI fU,.,,.,.,,. -**w OMB No. 20f<WO(H
- EJ(p;,. 2*29-IU I TO I
I (10-11)
(1l~J) (14*.6')
(.lfl "") (lll-111) (JO-JI)
NOTE: RMCI lnatrucllone before complellng.........
<.J C*rtl 011111 QUANTITY OR LOADING (4 C*rtl 01111)
QUALITY OR CONCllNTRATION PAltAM*Tll*
(46-JJ)
(Jf-61)
(Jl..fj)
(.f6.JJ)u (JUI)
NO. l"llllOUllNCY *AMPL*
01' ANALY*I*
TYP*
x (JJ.J7)
AVEltAGE MAXIMUM UNIT*
MINIMUM AVllltACH MAXIMUM UNIT9
'1-6J)
CIUI)
(fJ.70)
UO!:>.:JU
.l
- AMPLll
- SOLIOO,
'lUl'AL MllA*Ult*MllNT 30.00 30.00 0
1/31 GR SUSPENDED M:i/L PllllMIT EFFillENT GROOS ltllQUlltDl*NT 30.00**
100.00
- "1/30 GR 00340 1
- AMP'LE 1/31 CHEMICAL OXYGEN DEMAND Mll:A*UAllMENT 110.00 110.00 1
GRe*
- ,*. MG/L NltMIT EFFLUENT GOOSS 1t*OUIR&M*NT 100.00
- 1/30 GR 00551 1
- AMP'LE 1/31 i!RLTI MEAeUAEMENT 2.70 2.70 0
PETroLEUM
..... t-r;jL MDLT HYDIDCARBOOS flllltMIT EFFllJENT GOOSS llllOUlltllMllNT in nn ii:; nn
- 1/30 GR 50050 1
eAMP'LE NCJtE l MIEAeUAEMENT
. NCfI'E 1
- NOI'E 1 FI!M
.... M])
- ~*
flllltMIT 1/30
- "i, EFFLUENT GRffiS lll*OUlltllMllHT GR 00400 1
- AMl'LE 7.10 7.10 0
MIEA*URIEMENT 1/31 GR
?I SU PllltMIT EFFLUENT GROOS RISQUllll*MllNT 6.00 9.00
- 1/30'*
GR eAMP'LE MIEA*UAEMIENT
- NltMIT ltllOUllll... aNT
- AMP'LE MEA*UAEMENT l"llRMIT ltlEQUIR*M... T NAMK/TITLE P'RINCIP'AL ll:XllCUTIVll Ol'P'ICER I CCllTIH UNDER 1'£NAL TY OF LAW THAT 1 HAV( 11'1["50NALLY C*AMIN[D Ta.llflHONll DATS AND AM FAMILIAR WITH TH[ INFOltMATION SUllMITT[D Ht:MIN AND aASED
?f K Trejo ON MY INQUIRY Of' THOSC INDIVIDUALS 1-COIAT[LY R[Sl'ONSlllL[ F<llt
(~
J.
OBTAINING TH(
INFOAMATION I llKLl(:V[
THC SU-TT[D INf'OllMATION IS TRU[
ACCURATC AND COMl'l.[T[ *1 AM AWAllC THAT TH[ll[ AR[ SIG Radiation Prot./Chem. ~-
NIFICANT PfNALTl[S FOii SUBMITTING FALSE INFORMATION INCLUDING 1339-4399 TH( POSS191LITY OF f'IN( AND 1Ml'AISONMCNT SI:[ 111 USC I 1001 AND
- l~TURll OF P'RINC:~ EXl:CUTIVll 609 87 11 24 ll use' 1l'9 *Prnaltw1,.,.J,,,,.,., *'*'"'"' **** 111rludr ftr1.11 11P '" lltl.IMMJ TYP'ED OR rRINT*D
- ""..,,,......... "' tmpnatHU't1rnf '" hrllflf'f'll
- RllflRIA*.,., *'*'"'-'I OFFICER OA AUTHO ED AG*NT
- ~~!I NUM*IR YUlt MO DAY COMMENT AND EXP'LANATION OF ANY VIOLATION* (R,/rrrr1r* <11/ GllllC"llm*llU llrrr)
Note: Physical nodification required in order to obtain data.
489 is the Guard house yard drain reasuran1;mts are obtained only when sampling prot.oools are met *
. 45 nq/1 as a 7 day avg.
I PA Form 3320-1 (Rev. 10-79) l'RllVIOU* EDITION TO *it UHD
"*"'"""........ V I* l"WWAU*T_.h (RllP'LACU EP'A.FORM T*40 WHICH MAY NOT*& U*ED.)
PAGIE 2 0 OP' 20
e OPS~G Public Service Electric and Gas Company P.O. Box E Hancocks Bridge, New Jersey 08038 Salem Generating Station George Caporale - Chief Bureau of Permits Admin.
Division of Water Resources CN-029 Trenton, NJ 08625 Dear Mr. Caporale NEW JERSEY POLLUTANT DISCHARGE ELIMINATION SYSTEM' DISCHARGE MONITORING REPORTS SALEM GENERATING STATION PERMIT NO. NJ0005622 Novembe~ 24, 1987_
Attached is the Discharge Monitoring Report for Salem Generating Station containing the information as required in Permit No.
NJ0005622 for_ the month of October, 1987.
Thermal and *flow data for DSN 481-486 is unavailable as of the report dat~ and will be included with the November DMR.
This report is required by and prepared specifically for the Environmental Protection Agency (EPA) and the New Jersey Department of Environmental Protection (NJDEP).
It presents only the observe~ results of measurements and analyses required to be performed by the above agencies.
The choice 6f the measurement devices and analytical methods is controlled by EPA and NJDEP, not by the company, and there are limitations on the accuracy of such measurement devices and analytical techniques even when used and maintained as required.
Accordingly, this report is not intended as an assertion that any instrument has measured, or any reading or analytical result represents~ the true value with absolute accuracy, nor is it an endorsement of the suitability of any analytical or measurement procedure.
Exclusion explanations are included on additional pages.
PDB:pad Attachments C
Executive Director, DRBC Very truly yours,
- q~
/a~diation ~ection/
Chemistry ~tt:ger -
Salem Operations Director, USNRC Office of Nuclear Reactor Regulation Vice President - Nuclear Th USEPA p-Dr.1* Richard Baker e l:::nergy eop e 95-2189 (2.5c.11 6-33
NJPDES Report A
Explanation of Ex~usion~
October, 1987 11/24/87
.. The following exclusions are included in the attached* report* and explained below.
Ex6lusions have not endattgered nor sign1ficantly impacted public health or the environment.
DMR NO.
481,482 484,485 484,486 481-483, 484-486, FAC 4.87A
- 489 EXPLANATION TRC - Chlorination rate reduced immediately to decrease TRC valu~s. situation aggravated by unit outages and loss of normal cooling water and seasonally lower demand.
COD - Cause of. apparent.COD unidentified as of report date.
TSS -
Cause of apparent TSS unidentified as of repott.date.
FAC/ ~Temperature/Flow -.Data.
.unavailable as of r~port date.
. To be included in November DMR..
BOD* Removai Efficiency, Loading -
Suipected cause of decfea~e in BOD treatment efficiency is 400%
increase in flow due to unit outage work fore~ coupled wi~h seasonal temperature drop..
COD -
Cause of elevated COD unidentifie~ as of report ~ate.
. NJPD1ES Rt7portf Exp ana ion o Deviations 11/24/87 October, 1987 The following explanations are included to clarify possible deviations from permit conditions.
General -
The columns labeled, "No. Ex.", *on the enclosed DMR, tabulate the number of daily discharge values outside the indicated limits, Data reporting.and accuracy reflect the working environment, the design capabilities and reliability of the monitoring instruments and operating equipment.
All reported concentrations are based on daily discharge values.
Total residual chlorine is performed once per eight hours of chlorination unless otherwise indicated.
Analytical values which are less than detectable are reported as zero unless otherwise indicated.
N/A indicates no chlorination occurred during the report period.
Analytical results for all parameters other than pH, temperature, TSS and.TRC are provided by Century Laboratories (NJDEP certification 08153).
48C
- Clarifier ~ Effluent pH is reported for informational purposes only; 487,489 -
Measurements are obtained when sample acquisition protocols are met.
No means is currently available for flow monitoring at these locations:
482,485 - Total residual chlorine values are at times unobtainabl~ due to ongoing entrainment studies and the resultant equipment configuration.
Since all chemical treatments of or discharges to the circulating water system are common with at least one other discharg~.
those values are assumed t~ be identical for all parameters.
481-486 -
Chlorination of the circulation water system normally does not occur except as otherwise noted.
Service water system chlorination is normally continuous and is monitored on the circulating water system outfall due to the inability to sample service water effluent directly.
Chlorination of both systems will be indicated by results reported for both and represents their combined affect upon the circulating water outfall.
I.
- FonnT-VWX-014 5/83 NEW J.EY DEPARTMENT OF ENVIRONMENTAL ITECTION DIVISION OF WATER RESOURCES MONITORING REPORT -
TRANSMITTAL SHEET.
NJPDES NO.
REPORTING PERIOD MO.
Ylt.
MO.
Ylt.
h 10Is11 I THRu l1rol~11l PERMITTEE:
Nam* ___
P_ub __
li_*c __ s_erv
___ i_c_e_E_*_le_c_tr
__ i_*c __ & __
G_as __ c_o~------------------~
Address. P.O. Box E
.Hancocks Bridge, NJ 08038 FACILITY: -
Nam* _____ s_a_l_em __ G_£n
__ er
__ a_tin_*_..g __
s_ta_ti
'o~n~----------------------------
ButtonWood Road Address-------------..-.,;.;....... ____________________________ ~-----
Sancocks*Bridqe Telephone
( 609 ) 935-6000 FORMS ATTACHED. (lndlcat11 Quantity of Each)
SLUDGE REPORTS-SANITARY DT-VWX-007 DT*VWX-008 DT*VWX-009 SLUDGE REPORTS* INDUSTRIAL DT-VWX~010A DT*VWX*010B WASTEWATER REPORTS DT-VWX-011 DT*VWX-012 DT-VWX-013 GROUNDWATER REPORTS (County)
Salgp OPERATING EXCEPTIONS Y!S OYETESTlNG 0
TEMPORARY BYPASSING
\\
0 DISINFECTION INTERRUPTION 0
MONITORING MALFUNCTIONS 0
UNITS OUT OF OPERATION 0
OTHER 0
(Detail any "Yes" on reven11 sid11 in appropriate spact!.)
NO 0
o*
0 0
0 0
Ovwx-01s1A.Bl Ovwx-01e Ovwx-011 NPDES DISCHARGE MONITORING REPORT 0 EPA FORM 3320.1 NOTE: 11i11 "Haun Attt!nd11d at Plant" on tht!
- of thu sht!t!t must aiso M completed.
AUTHENTICATION
- I certify under penalty of law that I have personally examined and am familiar with the*
information submitted in this document and all attachments and that, based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the.
submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting false information including.the possibility of fine and imprisonment.
LICENSED OPERATOR Name (Printed) _____ P_a_u_l __
Behr ens Grade & Registry No. _s_-_3_, __ s_-_5_2_3_5 _______ _
Signature ___...._4
~:;;;.-..---**4c!-~-*--------------------
Date ---'--' /_._;1._s.... !..... r~?--------
PRINCIPAL EXECUTIVE OFFICER or DULY AUTHORIZED REPRESENTATIVE Name (Printed) ____ u_.,.o_hn
___ T_r_e....;;J::.... 0 _________ _
Titfe (Printed)
Rad. Brot./Chem. Mgr.
~, **
Signature -----"7~"--------q--+---------------
?. I/- l.5 - J 0
rf.J Date ------------------------------
- 41.
I OPERATING EXCEPTIONS DETAILED
. *---~-.
. ;.~.
. '*;_**~ *-
HOURS ATTENDED AT PLANT Month~
Year~
Day of Month.
1 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 Licensed Operator 8
8 8
8 8
8 8
8 s* 8 8
Others 2
4 4
3 4
4 4
5 4
3 3
Day of Month 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Licensed Operator 8
8 8
8 8
8 8
8 8
8 Others 3
4 3
4 2
4 5
4 4
5