ML18092B459

From kanterella
Jump to navigation Jump to search
Forwards Second Inservice Integrated Leak Rate Test & Type B & C Surveillance Test. Rept Includes Summary of Local Rate (Type B & C) Tests Conducted Prior to Second Inservice Type a Test
ML18092B459
Person / Time
Site: Salem PSEG icon.png
Issue date: 03/13/1987
From: Corbin McNeil
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18092B460 List:
References
NLR-N87038, NUDOCS 8703190356
Download: ML18092B459 (2)


Text

..

Public Service Electric and Gas Company Corbin A. McNeill, Jr.

Vice President -

Public Service Electric and Gas Company P.O. Box236, Hancocks Bridge, NJ 08038 609 339-4800 Nuclear MAR 13 1987 NLR-N87038 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

REPORT OF TEST RESULTS REACTOR CONTAINMENT BUILDING INTEGRATED LEAK RATE TEST SALEM GENERATING STATION UNIT NO. 2 DOCKET NO. 50-311 Attached is a summary technical report of the second periodic Inservice Containment Integrated Leak Rate (Type A) Test for Salem Unit No. 2.

This report is being submitted pursuant to the requirement of 10CFR50, Appendix J, Section V.B.

The test was performed during a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period which commenced at 0453 on November 26, 1986.

The test results indicate that the "As-left" integrated containment leakage rate, with corrections, is 0.043 percent per day (percent leakage - total time) of the containment volume at the 95% upper confidence limit.

This is in accordance with the acceptance criteria prescribed in 10CFR50, Appendix J and the Salem Unit No. 2 Technical Specifications.

The calculated "As-Found" integrated containment leakage rate was greater than the prescribed leakage limit due to the excessive leakage of valve 2PR25 reported in Licensee Event Report 86-012-00.

Also included in the report is a summary of local rate (Type B and C) tests conducted prior to the second inservice Type A test.

This summary includes "As-Found" data for informational purposes.

Sincerely,

S70319A. gg~~ ~~ggigl 1 I

P-DR PDR I f

Document Control Desk C

Mr. D. C. Fischer Licensing Project Manager Mr. T. J. Kenny Senior Resident Inspector

. Dr. T. E. Murley Regional Administrator NRC Region I MAR 13 1987 2