Public Service Electric and Gas Company Corbin A. McNeill, Jr.

Vice President -

Public Service Electric and Gas Company P.O. Box 236, Han cocks Bridge, NJ 08038 609 339-4800 Nuclear March 5, 1986 NLR-N86023 Off ice of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, MD 20014 Attention:

Mr. Steven A. Varga, Director PWR Project Directorate #3 Division of PWR Licensing A Gentlemen:

LOW-LOW STEAM GENERATOR LEVEL SETPOINTS FACILITY OPERATING LICENSES DPR-70 AND DPR-75 SALEM GENERATING STATION UNIT NOS~ 1 AND 2 DOCKET NOS. 50-272 AND 50-311

~

Pursuant to our telephone conversation with Mr. D. C. Fischer, of your staff, on February 10, 1986, this letter confirms and corrects an administrative error within the Salem Unit Nos. 1 and 2 Te~hnical Specifications.

The correction involves the Low-Low Steam Generator Level setpoint, which has inputs to two functions: Reactor Trip and Auxiliary Feedwater Pump Start.

In Technical Specifications Table 2.2-1, Reactor Trip System Instrumentation Trip Setpoints, the Low-Low Steam Generator Level trip setpoints were revised by Amendments 53 and 21 for Salem Units 1 and 2 respectively as requested in our License Change Request, LCR 83-06, dated May 4, 1983.

However, the same setpoints in Table 3.3-4, Engineered Safety Feature Actuation System Instrumentation Trip Setpoints, for start of the Auxiliary Feedwater Pumps, were inadvertently omitted from our License Change Request.

As we have been advised that this correction may be made without the submittal of an additional amendment request, have enclosed corrected pages to the Salem Technical Specifications for disposition as you deem appropriate.

$603110480 '860305 PDR ADOCK 05000272 p

PDR

Mr. Steven If you have any questions, please let us know.

Attachments C

Mr. Donald c. Fischer Licensing Project Manager Mr. Thomas J. Kenny Senior Resident Inspector Sincerely, 3-5-86

'