July 25, 1985 MEMORANDUM FOR:

Karl V. Seyfrit, Chief FROM:

SUBJECT:

Reactor Operations Analysis Branch Office for Analysis and Evaluation of Operational Data Robert G. Freeman, Engineer Reactor Systems Section 2 Reactor Operations Analysis Branch Office for Analysis and Evaluation of Operational Data SALEM UNIT 2 DEPRESSURIZATION EVENT Distrjbtftion PDR i' ROAB CF ROAB SF RFreeman Wlanning KSeyfrit EBrown Tippolito CHeltemes AEOD/E509 Enclosed is an AEOD Engineering Evaluation Report on the Salem-2 depressuri-zation event for your consideration.

The root cause for this event was attributed to failure of the licensee to effectively disable a set of low-temperature overpressure protection (LTOP) relief valves. Accidental depressurization of the RCS is an analyzed condition in Salem's safety analysis report, and it is concluded that adequate core protection was maintained during this event.

However, the study found that control circuitry for gate valves that permit valve reversal during its stroke is undesirable, and can result in valve failures that can lead to system upsets and degradation of safety systems functions.

Corrective actions taken by the licensee and Region I ~'Vere judged to be appropriate.

Thus, no further action by this office is deemed necessary.

/7/

~---~----- ------.._

-- ----a5o919AOD50~f g~gb~~11

\\

PDR PDR Robert G. Freeman, Engineer Reactor Systems Section 2 Reactor Operations Analysis Branch Office for Analysis and Evaluation s

Enclosure:

As stated cc w/enclosure:

D. Fischer, NRR F. Cherny, NRR J. Stone, VPB/IE

o. Tarnoff~ ~m of Operational Data SU:::::* *~~~~*j~* tc~~*~;.~*~;**, *** **~~*:;~*;i*t** **** *~i~~~~~ * ********************* ********************* ********************