ML18092A459

From kanterella
Jump to navigation Jump to search
Provides Info Re Steam Generator Tubes Plugged During Second Refueling Outage in Accordance W/Requirements of Tech Specs 4.4.6.5.a Re Inservice Insp of Steam Generator Tubes
ML18092A459
Person / Time
Site: Salem 
Issue date: 01/04/1985
From: Liden E
Public Service Enterprise Group
To: Varga S
Office of Nuclear Reactor Regulation
References
NUDOCS 8501100134
Download: ML18092A459 (2)


Text

-,-0 PS~G*

Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038 Nuclear Department January 4, 1985 U. s. Nuclear Regulatory Commission Off ice of Nuclear Reactor Regulation Division of Licensing Washington, DC 20555 Attention:

Mr. Steven A. Varga, Chief Operating Reactors Branch, No. 1 TECHNICAL SPECIFICATION 4.4.6.5a INSERVICE INSPECTION OF STEAM GENERATOR TUBES SALEM GENERATING STATION UNIT NO. 2 DOCKET NO. 50-311 In accordance with the requirements of Technical Specification 4.4.6.5.a, we are providing the following information regarding Steam Generator tubes that were plugged during the second refueling outage on Salem Unit No. 2.

Steam Generator No. 24 No. 23 No. 21 through 24 8501100134 850104 PDR ADOCK 05000311 G

PDR The Energy People Row 44, Row 25, Row 1, Tube Plugged Column 33 Column 10 Columns 1 through 5 and Columns 90 through 94 95-2168 (25M) 6-84

Mr. Steven 1/4/85 Should you have any further questions, we would be pleased to discuss them with you.

Sincerely, Manager -

Nuclear Licensing and Regulation C

Mr. Donald c. Fischer Licensing Project Manager Mr. James Linville Senior Resident Inspector