ML18092A321

From kanterella
Jump to navigation Jump to search
Advises That Capillary Drawings for Reactor Temp Detector Per TMI Item II.F.2 Reviewed.Listed Westinghouse Criteria for Areas Not Requiring Detectors Followed
ML18092A321
Person / Time
Site: Salem  
Issue date: 10/12/1984
From: Liden E
Public Service Enterprise Group
To: Varga S
Office of Nuclear Reactor Regulation
References
TASK-2.F.2, TASK-TM NUDOCS 8410190125
Download: ML18092A321 (2)


Text

..

PS~G*

Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038 Nuclear Department October 12, 1984

u. s. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Licensing Washington, D. c.

20555 Attention:

Mr. Steven A. Varga, Chief Operating Reactors Branch, No. 1

Dear Mr. Varga:

INADEQUATE CORE COOLING TMI ITEM II.F.2 SALEM GENERATING STATION DOCKET NOS. 50-272 AND 50-311 This is to confirm our previous transmittal which stated that no error is introduced in reactor vessel level indication due to vertical section of Reactor Vessel Level Instrumentation System (RVLIS) impulse lines without temperature compensation.

The following Westinghouse criteria identify when RTDs are not required for reactor vessel level error correction:

a)

Reference leg risers less than 2 ft.

b)

Reference leg risers greater than 2 ft where the "up" riser is cancelled by a "down" riser within an isothermal area.

c)

Impulse lines routed together in a common isothermal area.

d)

Horizontal runs of impulse lines.

,.,.--a41oi9oi2s a4!or~--~

~DR ADOCK 05000272 PDR.

The Energy People 95-2168 (SOM) 11-82

.: Mr. *Steven A. Varg' 10/12/84 PSE&G had reviewed the capillary drawings for RTD locations and verified that RTD locations conform to the above criteria.

C Mr. Donald c. Fischer Licensing Project Manager Mr. James Linville Senior Resident Inspector Sincerely, E. A.

Manager -

Nuclear Licensing and Regulation