Forwards Reactor Containment Bldg First Inservice Integrated Leak Rate Test & Type B & C Surveillance Test, Performed During First Refueling Outage on 830523.Summary of Local Leak Prior to First Inservice Type a Test Also Encl
Date released: 11/29/2018 Download: ML18089A421


Reactor Containment Bldg First Inservice Integrated Leak Rate Test & Type B & C Surveillance Test.
ML18089A422
Person / Time
Site: Salem PSEG icon.png
Issue date: 05/31/1983
From:
Public Service Enterprise Group
To:
References
Download: ML18089A422 (69)
Forwards Reactor Containment Bldg First Inservice Integrated Leak Rate Test & Type B & C Surveillance Test, Performed During First Refueling Outage on 830523.Summary of Local Leak Prior to First Inservice Type a Test Also Encl
ML18089A420
Person / Time
Site: Salem PSEG icon.png
Issue date: 10/13/1983
From: Liden E
Public Service Enterprise Group
To: VARGA S A
Office of Nuclear Reactor Regulation
References
Download: ML18089A420 (5)