Reviews AEOD Final rept,AEOD/P301, Rept on Implications of ATWS Events at Salem Nuclear Power Plant on NRC Programs for Collection & Analysis of Operational Experience. Subj of Reactor Trip Reliability Well Treated
ML18089A257
Person / Time
Site: Salem  
Issue date: 07/21/1983
From: Harold Denton
Office of Nuclear Reactor Regulation
To: Heltemes C
NRC OFFICE FOR ANALYSIS & EVALUATION OF OPERATIONAL DATA (AEOD)
Shared Package
ML18089A258 List:
References
NUDOCS 8307290045
Download: ML18089A257 (1)


Text

. -

~--------*

--~=-----..:;::_:....; -

MEMO RAN OUM FOR:

FROM:

SUBJECT:

c. J. Hel temes, Jr., Di rector Office for AnaJysis and Evaluation of Operational Data Harold R. Denton, Director Office of Nuclear Reactor Regulation DISTRIBUTION Central File NRC PDR L PDR NS! C PRC ORAB Rdg/

GHo 1 ahan HDenton/Case

  • PPAS TSpeis RMattson RVollmer HThompson NGrace BSnyder DPickett FMi ragl i a/

LBerry (839214)

DEi sen hut/

MJambor (839214)

MGarver (839214)

KBowman AEOD FINAL REPORT ON THE IMPLICATIONS OF THE ATWS EVENTS AT THE SALEM NUCLEAR POWER PLANT ON THE NRC PROGRAM FOR THE COLLEC]lQN AND ANALYSIS OF OPERATIONAL EXPERIENCE In response to your memorandum of July 1, 1983, we have reviewed the final AEOD report on the above subject.

This report is similar to the draft

  • report which we reviewed and provided comments to you on June 10, 1983.

As previously stated, we find that the subject of rea~tor trip reliability is well treated. In addition, the NRR activities in this area prior to the Salem A1WS events are accurately presented.

We support the proposed AEOD actions discussed in the reports' Executive

- S1W1mary.

Of particular importance wil 1 be the clari fi cation of existing reporting requirements and the continuation of AEOD's trends and patterns analysis.

We believe that the actions,being proposed by AEOD are correct

\\_:_,and should be beneficial in the long term.

\\ ;In *addition, we believe that the actions we are taking by the generic letter orf this subject (NUREG-1000. Volume 2) adequately addresses our mutual concerns.

--~ *-*

8307290045 830721 PDR ADOCK 05000272 S

PDR NRC FORM 318 110/801 NRCM 0240 Original signed hy E.G. Case Harold R. Denton, Director Off1 ce of Nuclear Reactor Regulation

~ :.

OFFICIAL RECORD COPY

  • U.S. GPO 19 s3-4 oo-247