ML18087A949

From kanterella
Jump to navigation Jump to search
Further Response to ASLB 820914 Order Re Subcontention 9(4) on Evacuation of School Children & Subcontention 9(5) on List of Invalids.Sufficient Measures Being Taken to Maintain Current List of Invalids & Senior Citizens
ML18087A949
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 12/17/1982
From: Copeland V, Gallo J
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.), ISHAM, LINCOLN & BEALE
To:
Shared Package
ML18087A950 List:
References
ISSUANCES-OLA, NUDOCS 8212210285
Download: ML18087A949 (3)


Text

  • ,

Public Service Electric and Gas Company Stanley LaBruna Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-1200 Vice President - Nuclear Operations DEC 15 1992 NLR-N92180

--~ - --

united states Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

INSERVICE INSPECTION ~LONG TERM PLAN FINAL RELIEF REQUESTS SALEM GENERATING STATION UNIT NO. 2 DOCKET NO. 50-311 By letter dated September 28, 1992 (ref: NLR-N92135), Public Service Electric & Gas Company (PSE&G) submitted the final relief requests of the Salem Unit 2 ISI Long Term Plan for the first inspection period.

  • These requests were submitted in accordance

.with 10CFR50.55a(g)5. to the September 28, 1992 letter contained the five final relief requests.

Final Relief Request #2 is being revised.

Due to a printer error, the last two lines of this relief request were inadvertently omitted. to this letter contains the revised page for Final Relief Request #2.

Shoul*d there be any questions with regard to this submittal, please do not hesitate to contact us.

Sincerely, Enclosure (1) xi~~

9212210285 921215 PDR ADOCK 05000311 G

PDR i

I

~;

'Document Control Desk NLR-N92180 C

Mr. J. c. Stone Licensing Project Manager Mr. T. Johnson Senior Resident Inspector 2

Mr. T. Martin, Administrator Region I Mr. Kent Tosch, Chief DEC 15 1SS2 New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625

SALEM UNIT 2 -

lST INSPECTION INTERVAL FINAL RELIEF REQUEST - # 2 COMPONENT DESCRIPTION:

Pressure Retaining Valves ASME CODE CLASS:

ASME Section XI, Class 1 Valves ASME EXAMINATION REQUIREMENTS:

Relief is being requested from the visual (VT) examination requirements of Table IWB-2500 Examination Category B-M-2 Item No.

B6.7.

BASIS FOR RELIEF:

The disassembly of functional valves during the first ten year

,inspection interval for the sole purpose of performing a visual examination of the internals would have increased the likelihood for component failure in the future and was contrary to good maintenance practices.

Considering the uncertainy of the benefit involved with this examination, it is difficult to justify the additional radiation exposure that would be incurred as a result of the disassembly, examination and reassembly these valves.

For exampie, estimates from radiation surveys performed on and around valve 2RH1 indicate that the total job dose that would be received in disassembling, examining and reassembling this valve be in excess of 4 man-rem.

Public Service Electric & Gas feels implementation of this examination is impractical for valves not scheduled for disassembly because of preventive or corrective maintenance.

In later editions of Section XI, this examination is only required to be performed on valves scheduled for disassembly for maintenance purposes.

ALTERNATIVE EXAMINATION:

Public Service Electric and Gas examined at least one valve in a valve group (valves of similar design and function) where at least one valve in the group was disassembled for maintenance purposes during the inspection interval.

If any valve examined was found to require corrective action, additional valves in that group would be disassembled and inspected as required by Section XI.

Utilizing the above guidelines, the following valves listed by group were never disassembled during the first inspection interval and therefore, the internals were not visually examined.

A similar relief request has been submitted for the second ten year interval per later editions of the Code.

Valve Valve Valve Valve Group Group Group Group 2RH1 2RH26 21SJ49 21SJ54 2RH2 22SJ49 22SJ54 23SJ54 24SJ54