NOVEMBER 1982 SALEM GE*NERATING STATION UNITS 1 AND 2 = CONTROL ROOM DESIGN REVIEW PROGR.AM PLAN* _J, ___ 1
- ----~----.....:._!
NOTICE - THE ATTACHED FILES ARE OFFICIAL RECORDS OF THE DIVISION OF DOCUMENT CONTROL. THEY HAVE BEEN CHARGED TO YOU FOR A LIMITED TIME PERIOD AND MUST BE RETURNED TO THE RECORDS FACILITY BRANCH 016. PLEASE DO NOT SEND DOCUMENTS CHARGED OUT THROUGH THE MAIL. REMOVAL OF ANY PAGE(S) FROM DOCUMENT FOR REPRODUCTION MUST BE REFERRED TO FILE PERSONNEL. DEADLINE RETURN DATE 7--plf/O RECORDS FACILITY BRANCH I I I I. I
i ! l ---~ r- ' i, I l 1* I: I. r-~ i_~ [ ' ~, i:-*~ L. f 0* l *i r' I.* u ["'1 d I I_ __ : I I L... I I,_
- g.
CONTROL ROOM DESIGN REVIEW . PROGRAM PLAN For. Salem Generating Station November 1, 1982 (Revised)
\\.:_'___.. t [_..; re. n I ! L~ .. r
- o*!
0 [ -~ (. L r l__ j J
- l.
- 2.
- 3.
TABLE OF CONTENTS Page INT'RODUCTIQN G o * *
- c *
- e * * * ** c G
e e o c * *
- o o o* o "ci 11 c c.
- G o o e e e *
- o a e o ct* o o c o Cl
- Bl 1.1 1.2 l.3 Purpose o
- e o ** Cl o ** e o
- o ** ci e *** o ** o o o **** o o o o o
- Q
- - o ** o o
- a e ** o o ~
- o o 1 Scope
- e 0
0 Cl 0 Cl *** 0 0 ** e e e 0 0 ****** 0 0 0 e Cl *** 0 0 *** Cl 0 0 Cl **** 0 Cl G G Cl 2 Schedule Cl ** 0 Cl ** 0 0 II
- D *** 0 0
0 0 0 0 0,c,
- 0 Cl ** ** 0 0
C> G **.... Cl e.****.**** ** G
- 3; M.AN'AGE?-mNT "AND STAFFINGc * * * * * * * * * * * *
- e *
- o o Goe Ci o *
- e * * *
- e
- e ***
- m*e G *
- e*o *.6 2.1 2o2 2.3 Management of the Control Room Design Review Process *********.*** 6 Structure of the Review Team ***** ~ ***************************** 10 Integration of Control Room Review with Other Human Factors Activities *** o****************************12 DOCUMENTATION. 'AND DOCUMENT CONTROL **** ~ ***.**** ~ ***.*******.**********, *. 15 3.1 3.2 3.3 3.4 Input Documentation *********.** 0 0. ***ID Q. e 0 e Cl **
, *. o ~ ***** t) ********** 15 Output Dc>cumentation *** ~ ************** Cl-Cl * ., **., ****.,.* o *********** 16
- t.
Document Control Procedures **************** ~...................... 16* Management of HED Records *. II..... ** ** Cl *** e. e ***.*************.****** 17
- 4.
PROCEDURES FOR THE CONTROL ROOM DESIGN REVIEW ************ ~............ 19 4.1 4.2 4*.3 4.4 4.5 4.6 Operating EXperience Review **.***************
- ~*********** * ** 19 Control Room. Inventory ** : ******* D **** o ***** *-*............... ~ ** ;..* 21 Control Room Survey ***** 0.......... Cle e e ** G ********* ** ******.* ! **** 22 System Function Review and Task Analysis *********************** 23 Verification of Task Performance Capabilities ****************** 27 Va*lidation of. Control Room Functions ************** * ************* 28 5
- HED ASSESSMENT AND RESOLUTION **********.***********************.****** 3 0 5.1 BED Categorization ********************************.****** * **** -** 30 5.2 HED Resolution ******* e *** o ***************.** ~ ****.**** * *********** ~3
- 5. 3* Schedule for Mod if ica tion *********.********** * ******************* 33.
PROJECT PROGRESS REPORT ***************************************** APPENDIX A DOCUMENT.RECEIPT/DISTRIBUTION LOG FORM *********
- .APPENDIX B RESUMES e e e e e e e e * *. e e e e e e e e e e e II
- APPENDIX C i
l A r-1 [__- n u [ -'"'i D D f:l. LJ I 1
- INTRODUCTION The approach developed for conducting the Salem Units 1 and 2 Control Room Design Reviews is described in this Program Plan.
Chapter 1 describes the purpose of the Program Plan as well its scope and schedule. Chapter 2 describes the plan for managing and staffing the Control Room Design Review. The anticipated input and output documentation and the procedures for controlling both are contained in Chapter 3. *The methodology for performing the Control Room Design Review is described in Chapter 4. Finally, a systematic approach for assessing any human engineering discrepancies that are identified as a result of the Control Room Design Review is described in Chapter 5
- The Program Plan, by definition, is flexible and subject to revision as the stages of the design review progress.
Since the Program Plan serves as input documentation to the design review process, the original document and subsequent revisions will be controlled in accordance with the procedures described.in Chapter 3 * . 1.-1 Purpose The purpose of the Program Plan is to ensure that the Control Room Design Review satisfies govern:ment and industry requirements, the results are under-standable and usable, and the benefits of human factors engineering are reflected in the control room design. Since the design review is rather l ~ involved and at times complex, the Program Plan also. documents the* review process, prov_iding t_raceabili ty of both the _process and the results of the LJ review.
- --- \\
I .. I ~ _ _; ' I " r---~ 1
- 1
IL_....: n I n L...l rl.J [ -:=>.!. -~ 0 l j ' L- [ r: L r*-~ I I i l."2 Scope The detailed control room design review will encompass the vertical panels and the console *in the Salem Units 1 and 2 control rooms and.theil:* corresponding hot shutdown panels. General Physics Corporation will provide. human factors consulting services. The Scope of General Physics involvement in the Control Room Design Review is tog Review input documentation, including any applicable operating experience data, plant design information, and app~icable standards and regulations. Survey operations personnel
- Provide an inventory of the control room instrumentation to meet the guidelines in NUREG-0700.
Perform a control room surv.ey which compares the control room design ~ith accepted human*engineering guidelines. Determine the input and output requirements of control room operator tasks by preparing a list of systems and systems functions *and analyzing specific control room operator tasks. Ver.ify that the tasks analyzed *can be performed in the existing control room. Validate that control room functions can be exercised. Assist in the assessment of any human engineering discrepancies uncovered in any of the review steps. Each of these items is described in more detail in Chapter 4. A flow chart depicting the interaction between the various items is shown in-Figure l. The consultant will provide a monthly progress report indicating funding and scheduling status, a draft report describing the review and the re.sults of the review, a final report based on P~blic Service Electric and Gas comments on the draft report, and *support for PSE&G during the Nuclear Regulatory Commission's (NRC) Review.
- 2
I \\ -~; ,-~ ' I r l D n I ! L.:: C r* I L f -* .. I ! I L-*,., 1.3 Schedule The Design Review is a complex process involving numerous elements. A schedule depicting the time-lines of major events is shown in Figure 2. 3
i ~-
- 1
'.~ ~ I i L_;* n J 1
- ~
- 0.
l 0 n c r-- I. \\_ ,.... "\\ L/* \\ ; l....! J R OPERATING EXPERIENCE REVIEW Fµ>W OiART OF OCRDR ACTIVI';t'IES
- 1~
SYSTEM FUNCTION REVIEW & TASK ANALYSIS VERIFICATION OF TASK _PERFORMANCE CAPABILITIES CONTROL ROOM VALIDATION* HED ASSESSMENT HED IMPROVEMENT/ IMPLEMENTATION Figure l 4 CONTROL ROOM INVENTO~Y ~-- . "/ /, I -* -. ---~- -*.I
r--~-:-. I,.. _.... i C-.. J 1--:--~. I.._. **~ ~ ~ il.:..__~-....--..._._ '*) 1982 SALEM DCRDR NOV DEC JAN FEB fv'IAR APR. PROGRAM PLAN OPERATING EXPERIENCE REVIEW Examine Documents Survey Personnel I \\ C.R. INVENTORY Input Inventory Data I. 1.' I ' 1* c:R. SURVEY. Perform.Checklist SYSTEM FUNCTION REVIEW & T.A. l.D. System Describe System Function l.11 Select Events V.T. Methodology T.A. Methodology Prefill T.A. Postfill T.A. VALIDATE C.R. FUNCTIONS Walkffalk Throughs Real Time Simulations (V.T.) I VERIFICATION Compare Task Requirements to Inventory Verify Adequacy For Use DOCUMENTATION Compile and Categorize HEDS (Prior & Present) Write Report Figure MAY JUN!:; *JULY AUG SEPT I i l i . I / I i i I I l I I i i I 2 I I I I OCT I NOV ' I I. I / DEC i I i I i I ..) .~ I 1~83 JAN FEB I I I
p.. \\ __ ; ! l l f 0 r l l i .:..~ c r: t -j J .(-"\\. I l LJ U n L f *: ~', Lj* )
- 2.
MANAGEMENT AND STAFFING Chapter 2 of the Control Room Design*Review Program Plan addresses the management and staffing aspects of the review. Section 2.1 describes how the review process will be managed. Section 2.2 describes the structure and qualifications of the review team. A discussion of how the Control Room Design Review interfaces with and is integrated into the other human.factors activities is contained in Section 2.3. 2.1 Management of the Review Process An overview of the sequence of events that comprise the Control Room Des-ign Review is contained in this section. The events described include data. gath~ring, analysis and documentation of results. The overview-is presented in a sequential ~nner, although individual events may at times occur concurrently. The Schedule in Chapter 1 displays the relationship of the individual events in the overall time,-frame of the review process. Ae Kick-Off Meeting An initial meeting will be held between PSE&G and the human factors consultant, General Physics. The objectives of this meeting are to: Establish review team structure and contacts Review and finalize the project schedule Obtain existing~ applicable documentation Each of these objectives is discussed below. (1) Establish review team structure and contacts. During the kick-off meeting, individuals from both PSE&G and General Physics will be identifi.. ed as members of the Control Room Design Review Team. Specific authority and responsibilities for each team 6
r I ; l l ; .~ \\ I
- i...J n
I : I. ~ L_J ! r Ci u [.. !. j 11 ~. J. L.J n tJ \\.._J r-: \\ : n l :
- '.j member will be identified and agreed upon.
In addition, an individual from both organizations will be designated as the primary contact for that organization. Reference Section 2.*2 for the proposed strucutre of the design ~eview team. (2) Review and finalize the project schedule. During the kick-_pff meeting members from both PSE&G and Genera_l Physics will review the project schedule (reference Section 1.3). Specific tasks will be scheduled ~6 permit an uninterrupted work flow for the review team, at the same time minimizing interference with control room operations. The end result will be a schedule extending from the beginning of the review through preparation and issuance of the final report.
- ( 3)
Obtain existing, applicable documentation. The kick-off meeting will take place at the PSE&G office and the initial data-gathering activity will begin at this meeting. The specific documentation is listed in Section 3.1. Review Documentation The documentation that was obtained at the kick-off meeting is to be reviewed to: Prepare for the control room inventory and survey Identify factors that may impact operator performance Conduct an operating experience review This review will be specifically geared toward obtaining information to be used in defining systems functions and analyzing operator tasks. 7
1.,.: I - , [ Fl lJ r I I.-* r u .\\1 u
- c.
Conduct Ph-ase I Site-Visits Site visits will be conducted to: Inventory the control room
- Survey the control room
- Survey operating personnel
- At the conclusion of these site visits, General Physics will have a listing of the instrumentation in the control room; a listing of Human Engineering Discrepancies (HEDs) identified during the Survey and a listing of inputs to the review from the operating personnel.
GPC will also conduct an exit meeting with the PSE&G review team at the completion of each site visit.
- o.
Define System Functions and Analyze Operator Tasks Systems important to safety will be identified from a li~ting of plant systems supplied by PSE&G. _ Using the results from the control room inventory, those systems that. are important to safety and a-re represented in the control room will be determined. - A functional description of each of these systems that are important to safety and are locatP.d in the control room will be prepared. From this, operating events to be analyzed will be identified. These operating events will be chosen to ensure that all systems which are important to safety and are represented in the co_ntrol room are exercised. The operator tasks which are involved in each -of the. operating events will then be analyzed. A special forni for the Task Analysis will be "pre-filled" for each operating event to analyze operator tasks and operator/system interactions. The descriptions of systems and functions and the pre-filled task analysis forms.will then be revie~ed by PSE&G prior to the next step. 8
(' ) : ~ (~.. ~
- i. ~*
n tJ ' [' n I.; u [ -. c,. . ) r-:-::-1 i**:*1 ! *_1 1.. :J l '~i Li . F": I *1. i.._.} \\ ; u E. Conduct Phase II Site-Visits ?ite-visits will be conducted to videotape the.operating events that were analyzed in the previous step. Operators will walk and talk through these operating events in the control room or in the simulator, as available. The information in the p~e-filled task analysis forms will be reviewed and perhaps revised during these walk~throughs. , F. Analyze the Videotapes to Identify HEDs After the operating event has been videotaped, oper;ators will be debriefed and the event will be analyzed using the pre-filled task analysis forms* and the videotape.. The result may be a second listing of HEDs that were not identified during the control room survey. G. Assess HEDs .The HEDs that were identified during the control room survey'and during the operating e~ent walk-throughs will be assessed for their safety implications. HEDs identified as having safety implications or potential for *safety implications will be categorized and a resolution implementation schedule will be reconunended. These assessments and recommendations will be used as input to the Phase II final report. _H
- Prepare Final Report Th_e methodology employed in the Control Boom Design Review and the findings that resulted from the review will be documented in a draft report prepared by General Physics for PSE&G.
The draft report will be finalized based on comments provided by PSE&G. I. Participate In NRC Review Meeting General Physics will' support PSE&G utility at any NRC meeting concerning the Control R9om Design Review.
- 9
- I I
\\ --- ( - i i
- - '/
[ -~ j r-.* u 1 ~:1. - -,J, u n 1 --1_
- ":I J.
Project Progress ~eports and Memorandum Reports To ensure that the activities described in these ten*steps are performed in a timely and cost-effective manner, General Physics will prepare a monthly progress report throughout the project. The progress report (see sample in Appendix A) will indicate both* funding and scheduling status. In addition, General Physics will _issue memorandum reports to PSE&G throughout the Review to allow timely review of perceived problems. 2.2 Structure of the Review Team Personnel from PSE&G and GPC will work directly.on the Detailed Control Room Design Review~ A description of each ~eview team follows. A. The PSE&G review team consists of the following four positions: Project Manager 0 0 Engineering Coordinator Operations Coordinator Design Coordinator The project manager is responsible-for providing support to the I : coordinators in the area of decision making throughout the project to ensure LJ 'I ~-~* r-- r -- 1 1*: ( l (. \\ /___ I \\ ; u satisfactory completion. The project manager also: 0-Provides administrative support for the project Interfaces with the GPC review team when necessary The individual assigned as project manager of the Control Room Design Review team is* a member of PSE&G's Controls Division. This individual has the education and experience necessary to function as project manager and team leader. The engineering coordinator is responsible for coordinating the entire Control Room Design Review. The engineering coordinator also: Maintains direct communication between PSE&G and the GPC review team. Works with opera'):ions and design coordinators_to provide the necessary documentation for the design review. 10
l The responsibility of the operations coordinator is to provide all operations support necessary for the review. The requirements of GPC along with the other me~ers of the PSE&G review team will determine the type of support r-which will be provided by the operations coordinator. This individual is also required to interface with members of the GPC review team as it becomes necessary. i I I.. r* I i i i \\_. __ The responsibility of the design coordinator is to provide all design support necessary for the review. The requirements of GPC along with the other members of the PSE&G review team will determine the type of support which will be provided by the design coordinator. This individual is also required to interface with members of the GPC review team as it becomes necessary. r** B. The General Physics review team consists of the following three positions: i I i I
- r.
(. t -- ! L
- ~,
i L_. Project Manager Project Director Projeet Staff The project manager is responsible to PSE&G for all project work and reports administratively to the project director. The p~oject manager has the responsibility and authority to: Prepare the project quality plan Implement qual_i ty assurance procedures Maintain communication with PSE&G on quality *affecting project activities The individual assign~d as project manager of a Control Room Design Review is a mei:nqer of the General Physics Human Factors Engineering Group. This individual has the education and experience necessary to function as project manager and team leader of a Control Room Design Review. The project director_ is ~esponsible for ensuring that the ~reject manager has the support of General Physics Corporate Resources, when necessary, to support the project. The project director reports through department and
n f (" __ : r *- I (_ :* r l~-* r1 L.;; ,.,., l ; L...! [ n u w ~:.- r:? . l _J [1 { i .r r-*1 r-1 r-- -~. ' I 1..__j [\\ r*: i [ (""i I I L.-' c~ I l u i divis'ion management to the *office of the president ct: General Physics. The I project director has the responsibility and authority to: Assist the project manager in staffing the project Coordinate technical support for the project Provide administrative support for the project The project staff members report to the project manager. The staff members participate in data.collection, analysis, and report writing and at times may directly interface with PSE&G personnel. Depending upon the extent of utility expertise and participation in the review process, the staff may consist of per.sonnel with the following expertise: Human facto.rs engineering Power plant operations Cl Training Systems analysis Design engineering Computer applications Each staff member on the review team will be assigned specific responsibilities corresponding to his or her level of education and experience in the required area of expertise. A diagram showing the design review team.structure and the primary contacts between PSE&G and General Physics is shown in Figure. 3. Individual role assignments are provided with the resumes in Appendix c.. 2.3 Integration of Control Room Design Review with Other Human Factors Activities The CRDR will be interfaced with other on-going human factors programs at the Salem Generating Station. Examples of other relevant work are shown in Figure 4.
\\. ~-. f r---; i l I._
- _.,/
L __._... *~J GENERAL PHYSICS CORPORATION I PROJECT DIRECTOR I TECHNICAL SUPPORT I ADMINISTRATIVE SUPPORT PROJECT MANAGER PROJECT
- STAFF, CONTRACT ADMINISTRATOR Figure 3 Design Review Teain Structure
,-~ . j ~-.-., L j
- ~. --.....'.)
.. i
- . ~-.. -.. :
PUBLIC SERVICE ELECTRIC & GAS I !ENGINEERING COORDINATOR PROJECT MANAGER DESIGN COOR DINA TOR I I OPERA TJONS COORDINATOR PRIMARY LINES OF COMMUNICATION CORPORATE BOUNDARIES
r-* 1 * \\ l I L....: I \\....: L _ n 1._) r-, I. ("' u .. l f
- .. ~ -
..:...J r-; . I !
- r. _ _;
,--1 l '.".1 r*-*. I ~-.__1 r** ~* : i. i Other Action Plan Items ~ 899 NUREG-0 GUIDELINE THE PREPAR OF EMERG OPERATI PROCEDU S FOR ATION ENCY NG RES 1750 NU REG/CR* ANALYSIS RECOMMENDA CONCERN OPERATOR LIC TIONS ING ENSING I\\ \\ \\ \\ \\ \\ I I / NUREG-0660 TMI ACTION PLAN If*. NUREG-0737 TMI CLARIFICATION NUREG/CR-1580 HUMAN ENGINEERING GUIDE (DRAFT) NUREG-0659 STAFF SUPPLEMENT 11' NUREG-0700 CONTROL ROOM DESIGN REVIEW NUREG-0801 EVALUATION CRITERIA (DRAFT) Figure 4 I I I I I I NUREG-0696 FUNCTIONAL CRITERIA EMERGENCY FACILITIES ,_ r*--~---~ '\\ I REGULATORY I "t GUIDE1.97 I I I '-3------~~ Relationship Between NUREG-0700 DCRDR and Other*NUREG Documents 14
I
- I
( _ r-,
- I
~ [ -~ j [
- ~J
[ ,--~ 1-, 3
- DOCUMENTATION AND OOCUMENT CONTROL A large number of documents will be referenced and produced during the Control Room Design Review.
Therefore, a systematic method for controlling these documents is necessary. The input and output documentation that has
- been identified to date and the process by which these documents will be controlled is descr ib.ed in this chapter.
3.1 Input Documentation . The following documents have been identified as possible reference
- material to be used during the review process.
As the review progresses it is anticipated that additional material will be identified and referenced. Therefore the following list of documents, if available, is preliminary. Licensee Event Report.s o Incident Reports * - Fault trees and failure mode and effects analyses Final Safety Analysis Report e Systems* descriptions o Piping and instrumentation drawings e
- Control room floor plan Panel layout drawings Panel photographs o
Lists of acronyms and abbreviations used in the control room o Descriptions of coding conventions used in the control room o Software descriptions, including CRT formats and content e Samples of computer printouts e 0 Procedures currently in use (emergency, operating, etc.) Operator training materials Control Room Preliminary Assessment
- Guidelines for_procedure development Instrumentation and controls list Annunciator and label engraving lists 15
I I 3.2 output Documentation L_: f.~ Throughout the review process documents will be processed-' to record data, r: I ; L.:..: I, c D c I 1 I I. L [ document analyses and record findings. Whenever possible, and appropriate, standard forms will be developed *and utilized. All of the documentation produced during the course of the review will be controlled in accordance with the procedures described in Section 3.3. The following list represents a preliminary estimate of the types of documents that will result from the
- review and be submitted by General Physics to PSE&G:
Control Room Design Review Program Plan Project schedule List of control room instrumentation I 0 Control room survey checklists Operator questionnaire Human Engineering Discrepancy form Project memorandum. reports List of plant systems List of systems repre~ented in the control room Description of control room.safety systems functions
- Description of operating events analyzed Task analysis form
\\ List of HEDs assessed according to their safety implications Summary Control Room Design Review Report 3.3 Documentation Control Procedures The General Physics Project Manager will designate a review team member who will be responsible for documentation control. All-documents received from PSE&G, used as primary input to the review, or generated during the review wili be subject to the following control procedures. 16
r---. i I \\... - r*-. ' I, t -* r; i ~.. _. l I
- I I
~.~ (.,_., I I u r-~* I ' u I [ _ [ I, I [_; L A. Log-in Procedures All documentation received and generated during the review will be logged into the GPC Document Receipt/Distribution Log. The.log contains the document iqentifier, the revision level, the. date received,. and individual(s) to whom the document is distributed (see Appendix B). B. Internal Routing After documents have been logged, they are routed to review team members. If the document is too large to be routed, e.g., an FSAR, a memo giving the document date, title, and revision will be routed.* After all team members have signed the routing sheet, the document will be returned to.the* document control person. Log-Out *procedures In a: manner s'imilar ~o the log-in procedures, all documents will be controlled through a log-out procedure~ Once again, the document identifier, the revision level, the date sent, and to whom it is distributed will be logged. In the case of revisions, the s~erseded version can*be recalled concurrently with issuance of the latter version using the Document Rece.ipt/Distribution Log Form (see Appendix ~). D. Document Filing All project documents will be maintained in a project file.* The document control person will periodically insure that no material has been removed from the* file that has not been properly logged-out. 3~4 Manage-inent of HED Records All information pertaining-to HEDs 'Will be stored in the General Physics Corporation PRlME I-1000 computer via General Physics' HEDSMAN (Human !_ngineering..§_torage and MANipulation) System. The HEDSMAN software was written specifically for the collection, storage, manipulation and tracking of HED-associated data. The system will be used to provide assurance that all 17
r*-~ ~ \\ __, i I \\._: r1 (_j ~- _... I i L~ ('"*.., I (_ r*- L_ _; HED data are accurately recorded, organized, and assessed. Cross-referencing
- among files will be provided.
Fo~. example, all componen~ infprmation for an HED can be compared to the data collected during the Control Room Inventory. Furthermore, an inquiry.to the HED data file can result in a listing of all HEDs affecting any system, subsystem, or componento 18
~- l __ J. 1 4
- PROCEDURES FOR THE CONTROL ROOM DESIGN REVIEW i I,
A description of how the control room design review process is to be accomplished is contained in this chapter. The review is divided into the r*--. ) : following: r..... r--. I I l.....: r _j r1 I : t.J I L.. : I" I l~ r.. I 'I i r-* L
- o Operating Experience Review Control Room Inventory Control ~m Survey System Function Review and Task Analysis-Ver ification of Task Performance Capabilities Validation of Control Room Functions and Integrated Performance Capabilities.
A procedure fo~ each follows. However, at this stage the procedures are preliminary and may be* revised as the. review progressese 4.1 Operating Experience P-!view Two separate steps are involved in reviewing operating experience. The first is to review available and applicable documentation: The second is to survey operating perso~nel. Each is addressed separately. A. Documentation Review Operating experience documentation will be reviewed in an effort to i9entify problems.that have occurred in the past which could impinge on control room operations *. Therefore, the following items will be considered as possible review documents. Licensee Event Reports Final Safety* Analysis Report Modifications to Technical Specifications Incident Reports 19
0 lJ \\ Li (... 1,.:: I. '?
- 4.2 Control Room Inventory An inventory of all instrumentation, controls, and _equipment in the control room will be prepared.
Instrumentation, controls, and *all equipment used for remote sh~tdown will also be inventoried. The inventory will
- identify systems and subsystems: instrumentation and controls (components) related to each: emergency equipment, conununication devices, procedur-es and any other items physically present in the control room. Selected features of instruments to be specified include parameter ranges and unit of measure *
. Prior to actually performing the inventory, the following documents will be reviewed: Plant layout Control room layout A/E drawings 'Instrumentation and controls listing 0 Annunciator and label engraving lists
- cRT formats and content in hardcopy Plant operating ~rocedures Control room photographs Photographs of the control room will be provided for use. in the review.
There are three objectives for obtaining control room photographs: To provide an "as built" documentation of the control board at the beginning of the review and to provide an overall reference for the control room for later identified HEDs. To document corrective measures taken in an ef'fort to resolve the HED's and, To provide a necessary element of a control room review for submittal to the NRC *. Once the control room** inventory is complete, all items physically located in the control room and remote shutdown area will have been identified. The results will be documented in a form suitable for use during the verification of task performance capabilities.
r-... l i l... r~
- 1. __
r-
- 1.
l....
- r.
1 ! I' I ; . _.J [ [ r*-~ { *-, I L.~ "Also, any other documen~ation that could provide insight into control room operability will be reviewed *.. Industry-wide information.on plant;s most similar to Salem will also be surveyed in an effort to identify useful documentation. General Physics and PSE&G.will agree upon the list of documents to be reviewed prior to this step of the review. Any problems that are identified.as having potential impact on control room operations will be documented and examined* later in the process. B. Operating Personnel Survey Operating personnel will be surveyed to eli~it information regarding positive.and negative aspects that have been noted during actual or simulated operation. A questionnaire will be used to sample operation opinion and elicit recommendations. Areas that will be addressed inc~ude: Controls Displays Annunciators and alarms Procedures Computer systems Works~ace environment Control room workspace 0 Panel layout The information collected from the operations personnel will be documented for examination later-in the review process. Follow-up interviews with respondents will be scheduled, as necessary, to clarify or elaborate on questionnaire results. 2o
n I I I 1 Lc.J [ __ j D [ l _j r; l :__! 4.3 Control Room Survey The purpose of the* control room survey is to compare design features of the control room to the human engineering guidelines presented in NOREG-0700 and other relevant human factors standards. Checklists will be used to provide a thorough and efficient meth~ by which.direct observation and measurement of control room features may be undertaken. The checklists organize. guideline items under the broad categories of instruments, equipment, layout, and ambient conditions. In the control room survey, checklists will be used to eva,luate each system with the 'purpose of identifying control room characteristics that do not conform to accepted human engineering practices. Thus, the survey will be used to identify discrepancies which will later be evaluated as to their potential effects in the final*systems context. While most of the checklist items* are applicable at the component level,. some guidelines apply-to specific task uses of instruments and equipment, 'task sequence requirements, communications requirements or other aspects of dynamic pperation. These dynamically-oriented guidelines may be most appropriately addressed from the task or function perspective described in Section 4.4. Specifically, checklist items will. be hierarchically organized for t'eference ease and will provide space for an indication of compliance or noncompliance to each guideline. When lack of compliance is found, a specific. I l reason or reasons will be clearly described in an adjacent space. Items which [ L r***, I I i : ~ require further documentation of a human engineering discrepancy will be described in greater detail as a separate record cross-referenced to the checklist. Photographic evidence of at least one example of each type of HED. will also be provided if feasible.
r L-.J * [ -c: 0 [ o* ~ . F_~'* 13-
- }
\\ [ Some guidelines wi11 *be addressed primarily on a control-room wide basis such as those that fall in the categories of communications, process computer,
- control r~m layout, and environmental factors.
Others.will be approached on a control-room wide basis first, and then panel-by-panel, such as the annunciator system. and layout. Still other guidelines will be evaluated element-by-element, and then for general control roomcc;:insistency, such as controls, displays, labels, and location aids. Finally, control and display functional grouping and integration will be
- examined panel-by-panel and control-room wide.
Control room operators or s*upervisors will be especially helpful at this stage given t_heir detailed* knowledge of the panels as well as their operations experience. c
- 4.4 System Function Review and Task Analysis The flow of activities which comprise the system function review and task
_ analysis is represented in Figure S. This* step in the review process is .. performed to determine the input and output requirements of operator tasks involved in selected opera~ing events. These requirements will be used later . in.- the review to assess the adequacy of the control room design *. For clarity~ . the procedure fo_r determining* these input and output requirements is divided into the following four parts: Identify systems Describe system functions Identify event sequences Identify and analyze operator tasks [~ Each is discussed separately below. [ A. Identify Systems From plant documentation, a list of plant systems will. be prepared. From this list, those that are important to safety will be identified.
LIST PLANT SYSTEMS 1
- IDENTIFY SAFETY-RELATED SYSTEMS 1
PREPARE FUNCTIONAL DESCRIPTION OF SAFETY-RELATED SYSTEMS SELECT OPERATING EVENTS FOR ANALYSIS PERFORM ".PRE-FILL" TASK ANALYSIS FOR SELECTED OPERATING EVENTS I VIDEOTAPE WALKTHROUGH OF SELECTED OPERATING EVENTS REVISE PRE-FILLED TASK ANALYSIS FORMS USING VIDEOTAPES DETERMINE HEDs FROM COMPLEJ.ED TASK ANALYSES
- figure 5 Systems Function Revie*., and,_ Task Analysis 24
"\\ ! I. I I,.' 1* r, L ( ) !..__/ L. r-* j I L I,:
- (.....
- c.
Identify Event Sequences Two sources-of information will be used.as the primary basis fcir identifying the event sequences to be analyzed. The first is the result of the operating experience review. If a particular event has been problematic in the Salem plant or in similar plants, it will be identified and analyzed. The second is the list of systems that were identified as being important to safety. The objective in identifying events to be analyzed is to choose events which will exercise all of the systems that are identified as being important to safety. Therefore, a matrix-type form will be developed to compare "safety important" systems and operating events. In this manner, operating events will be chosen to ensure that each major system that is impor.tant to safety is included in* the task analysis. The types of operational events that will be considered for analysis are: Small break LOCA Start-up from hot standby to minimum load Anticipated transient witho~t_scram, ~ollowing loss of main feedwater Inadequate core cooling Steam generator tube failure Shutdown for refueling Large break LO:A Control room evacuation The list of events to be analyzed will be approved by PSE&G p'rior to the initiation of task analyses. D. Identify and Analyze Operator Tasks After the operational events have been identified, task anlaysis forms will be pre-filled for each event. The purpose of the pre-filled task analysis form is to document the operator tasks and task resource requirements necessary to perform the operator functions required in each operating event analyzed.
The primary criteria that will be used to determine* the safety importance of systems is whether the system is designated as safety-related, e.g.' Class lE, in the plant documentation. In additio~, the following three factors will be considered: Manual control systems needed by the opera tor for real-time support to prevent plant trips.* Manual control systems needed by the operator for* post-trip control of decay-heat transfer from the core to the various heat sinks in the plant. The degree of interconnection on non-class lE systems. A system which is highly interconnected with other systems may be a source for causing many systems to fail as failure may propagate over the connections. After the syStems have been designated as being important to safety, those systems whlch are controlled or monitored in the control room will be identified. B. Describe System F*unc.tions, Descriptions of the functions for each of the sy~tems identified in the previous step will be prepared. The list is comprised of those systems that are important to safety and are con~rolled or monitored in the control room. These system descriptions will include: The function{s) of the system {"function" is defined as a mission or goal) Under what conditions the system is used A brief explanation of how the system operates These descriptiOns will be used as input to the task analysis.
---*---*---*---------***--*~*---*----*. -* **"****--** *-* -****.-- *-*-- - r-**- 1 I \\ 1... - j' j I. c r* - I "/) \\ I r.... __. I I f I ' I ' i L. The task analysis forms will be pre-filled prior to on-site visits to minimize time on site and disruption to the plant control room. _The system functional descriptions will be used as the.starting. point during these paper-and-pencil task analyses. Tasks explicit and implicit in procedures will also be identified arid described. For each task, operator
- actions and informatfon requirements will be drafte~. The information contained on the task analysis form will include:
o Operator subtasks Description of operator behavior 0
- O System/subsystem
- rnput requirements Output requirements System/subsystem response Time sequence e
System performance criteria
- consequences to plant of error /omission.
Functional descriptions and procedures will not provide sufficient detail t9 allow the task analysts to fully determine sequential ordering of actions, control/display location, optional elements, minimum symptoITIS to diagnose a problem, and other information at the task element level. Some of this information will be provided by station personnel prior to the walk-throughs. The remainder will be collected during real-time performance of the events (reference Section 4.6). 4.5 Verification of Task Performance Capabilities The objective of performing this step in the review process is to determine if the instrumentation and controls that the operators need to perform their tasks are available in the control room and, if they are, to determine if the design' allows for effective human/machine interface. In order to ensure that this step has been adequately addressed, the procedure described below will be performed_ at least twice. The first time will be prior to the on-site visit when the talk-throughs of the operating events are conducted. The second time will be after the video-tapes of the walk-throughs have been analyzed.
Briefly, the procedure for determining if the necessary instrumentation and controls are available, and if there are any interface problems connected with the simulated operating event, is as follows: e Information on input and output requirements from the task analysis forms will be compared with the control *room inventory list. Any instrumentation or controls that are required but not present in the control room will be noted as* possible HEDs
- If the instrumentation parameters do not agree with the parameter information requirements it will be noted as a possible HED.
. If instrumentation or control features do not allow successful task completion, they will be noted as possible HEns. The possible HEDs ide_ntified prior. to the walk-throughs will be evaluated to ascertain if they constitute a discrepancy in the contex~ of the control room. After the operating event walk_-throughs have been analyzed, additional HEDs may be identified. After the selected operating' events have been analyzed, a check will be made to.determine "if the control room contains instrumentation or equipment that may not be necessary. If this condition exists, additional evaluations will be performed to ascertain if the instrume~tation or equipment s:1ould be altered or removed. - The procedures identified in this section will result in a compilation of* HEDs that have been identified throughout the Control Room Design Review process. If an item is identified as a possible HED, and is later found to not actually be a discrepancy*, it will be eliminated from further analysis. 4.6 Validation of Control Room Functions After the task analysis has been pre-filled and verified as described in Sections 4.4 and 4.5, a walk-through of. the selected operating events will be conducted. At this time, any additional information will be recorded on the task analysis form. The operating event walk-through will be video-taped to provide a means for later analyses of the tasks and to minimize the time required on site. If the simulator is available, the walk-through will be
e ( \\ video-taped in a real-time situation. If not*, '.~ simulated walk-through will be video-taped in the control room or in an authentic mock-up. As much information* as possible will be collected during the walk-through.
- However, it is anticipated that the major portion of the task analysis information obtained from the Wa.lk throughs will be recorded and analyzed from t}:le video~
tapes at a later date. The primary purpose of this *step is to identify dif.ficulties, based on the control room design, in accomplishing the necessary tasks involved in the operating event, to ascertain the validity of previously identified discrepancies, and to identify any discrepancies not previously recorded. Once the video tapes have been analyzed, the task analysis forms will. have been completed. Then the procedure described in Section 4.5 will be repeated to finalize the list of HEDs identified throughout.the review proeess. / /
- 5.
HED ASSESSMENT AND RESOLUTJ;ON The design review team, comprised of PSE&G personnel and General Physics personnel will assess identified discrepencies and recommend corrective actions for their resolution in an iterative review process. Descriptions of procedures for assessing and categorizing HEDs and recommending corrective actions are contained in this chapter. HED categorization HED resolution Sc.hedule for modification A procedure for each follows. These procedures are tentative and subject to revision
- 5.1 HED Categorization
. ( -:--\\ ....... _._../ (**~. \\.__.:./ The categorization process is designed to assess and prioritize HEDs. Review team members from both PSE&G and General Physics will participate in the categorization of HEDs. All identified HEDs will be categorized as follows: Category I - HEDs Associated with Documented Error Category II - HEDs Associated with Potential Errors o Category III - HEDs Associated with Lo~ Probability Errors of
- Serious Consequence e
Category IV - Non-significant HEDs The categorization process is shown in Figure 6. Categorization.will be determined by: Previously documented errors O:RDR team judgement of potential for error e Cumulative or interactive effects Impact on plant operational safety
..** --.*.*.*. 0 -****--**.. *** t
- .**/,,.,.,--\\
\\ r--, l. 'L.. CAT Ill ~ *-c*). L.------1
- .*.. /LOW PROBABILITY ERRORS WITH SERIOUS CONSEQUENCES I
l - \\. - r. No
- i No CAT IV HED CATEGORIZATION PROCESS No No Yes CAT II POTENTIAL, INTERACTIVE
&.CUMULATIVE ERRORS NON-SIGNIFICANT HEDS Figure 6 (adapted from NUREG-0801) CAT I DOCUMENTED ERRORS
i.. A~ Category I - HEDs Associated with Documented Errors All HEDs which have been previously documented (as determined by the - operating experience review described in Section 4.1) as having contributed to an operating crew error will be determined to be significant and assigned to category I. B. Category II - HEDs Associated with Potential or Interactive Errors HEDs placed in category II may come from two sources: Those which degrade performance and increase the potential for error
- Those which. have cumulative or interactive effects Each of these two is discussed below:
(l) It is the responsibility of the review team to judge the significance of HEDs *. In order to reduce the subjectivity of such a judgement, review team members will answer a series. of structured questions, designed to indicate the effects of the HED on operating r,rew perfQrmance. If it is judged that the HED degrades performance and if the effects of the HED are judged to be serious enough to cause or contribute to increasing potential for operating crew error, the RED will be determined to be significant and assigned to Category II. (2) Any HED which does not degrade performance, which does not increase the potential for operating crew error and does not have adverse safety consequences will be further analyzed to determine if it has any cumulative effects or any interactive effects with other HEDs. This determination will be based upon knowledge derived from the review of systems, subsystems, panels, components and functions/tasks, as well as from human performance references. If the HED is determined to have a cumulative or interactive effect it will be assigned to Category II.
,/,.-~.,\\ i, I-* L... I ( \\ "--~~) Category III - HEDs: Associated with Low Probability Errors of Serious Consequence BEDs initially determined to have a low potential for error will be further analyzed by the review team, in terms of the *effect of an error on plant operational safety. HEDs with a low probability for error, but which could result in adverse conditio~s if such an error did occur, will be determined to be significant and assigned to Category III. D. Category IV - Non-significant HEDs Any BED which has been analyzed and* determined neither to -increase the potential for causing or contribut~ng to an operating.crew error, nor to have. adverse safety conse*quences, -nor. to have any cumulative or interactive effects will be assigned to Category IV. t* Categories will be broken down into levels and each HED will be further analyzed for level determination. Levels wili be determined by: System importance to safety Severity of consequences 5.2 HED Resolution Recommendations for HED resolution will be proposed for all _HEDs. Corrective actions will be developed using the resources contained in the DCRDR team and other specialists (e.g. Plant Engineering Department). The recommendations will take into account the impact of the correction on operating effectiveness, system safety, acceptability of design,_ consistency with control room characteristics and cost. 5.3 Schedule for Modification The development of a schedule for modifications of HEDs is *dependent on HED categorization and PSE&G decision.
APPENDIX A PROJECT PROGRESS REPORT
.. I iO jO I* .~ \\Q.* I I -..,. -. ' ~ i I '* I. I
- O
.-.. ___, ____.. ~ 1,01.
i
- nCX) CIS.UW Tl'nH7.I
-~
C')
- ~........:...:.. /
- l.
- 4) e e Peter A. Doyle Project Director ***** ~ ************** "*******~*****o***"******Donald c. Burgy "Project Staff ******O*****************"*****Claudia Lempges (Human Factors)
- &***********************Richard Corfield (Operations)
- *"* **** *"* ** Patrick casey (Operations)
- &***********************Richard Corfield (Operations)
- (*----.--:!
- l..*
- drawings.
- -*- \\..... _..,,,...
- --*-******-**-**-~--*-* **- -*
- New York District sales representative for the* chemical industry and industrial contractors. Products included industrial instrumentation, control systems, and special purpose computers.
- installations. Dealt primarily with combustion systems for the utility and marine industries*.
- Public Service Electric and Gas Company Engineer - Controls-Division England Makes desigr. changes to existing systems involving instrumentation and controls, to maintain reliability and the safe operation of a Nuclear Generating Station.
- design changes.
- equipment.
- _.)
- develop a generic implementation plan for the industry to use in implementing the approved emergency response
- Nuclear Training Specialist Primary Responsibilities:
- U.S. Navv I
- COMPANY TRAINING COURSES Fundamentals of the Critical Path Method of Planning and Scheduling Supervisory Skills Program - Management Personnel Quality Assurance Orientation for Engineers
- As Assistant C.hief Designer Controls, I am the functional head, in the absence of the. Chief Designer, of the Controls.
- f **
- planning, studies, specifications, bid analysis, vendor selection*, purchasing, supervisio~ of drafting, both piping*
- and wiring,. rev.iew and approval of* vendor's drawing, inspection, functional testing and bid requotes of all control panels. Author of the Design Manual, Section 6, entitled "Standard Instrument Control Panel Design Philosophy." Design Engineer. for.the control panel at Shell Chemical Deer Parle Plant. This panel was subject* to I.S.A paper giv~n at 1969 Houston Symposium.
- orders for instruments *.
- . General Physics.
- *Research Assistant Mr. Doyle's duties included helping formulate objectives for modularized maintenance training courses for the Federal Aviat~on Administration.
- research concerning auditory pattern recognition.
- ,c,*
- EPRI, September, 1981.
- Columbia, MD, General Physics Corporation, June 1980.
- .UNPUBLISHED PAPERS "Preliminary Assessment Human Factors Review of the William H. Zimmer Nuclear Power Station Control Roomn (Cincinnati Gas & Electric Company, GP-R-13046).
- Additional task analytic experience has been largely for the Navy SUBACS (Submarine Advanced Combat Systeins) program.
- auditory signal classification of complex underwater sounds.
- Room" (Virginia Electric & Power Company, GP-R-705).
- Columbia, MD, General Physics Corporation, June, 1980 "Human Factors Engineering Recommendations for. Near-Term Improvements of the Zimmer Nuclear Power Station Control Room" (Cincinnati Gas-and Electric Company), GP-R-13002). -
- l'l_Program Plan:
- ~
- responsible for development of task analysis and data '
- parents.
- Christmam, M and Lemges, c.
- c-23
- -. ---- -
- __... ----**-. ---*- --* ~----**-* *- _____, __ _p ____ -*-* ------.- --
- 1) Human Factors Engineering input to the Accident Monitoring. System.
- 2) Design of the page control module.
- ISD-80-1179.
- 3) Human factors considerations for I&CE products.
- 4) Standard List of engineering unit-abbreviations for NUPLEX 80.
- 5) Standardization of. data status messages IS0-80-1168.
- . ~
- Mr. Rogalla provided human engineering ex:pertise*to accomplish the installation of viable electrical communications systems for the new Hospital -
- ~
- ,,/
- preparati~n, on-site licensed* and non-licensed -training and training program development.
- --*--*----~----**-***-**
- ~,
:----:-~=----::-==::-:-:::::::--:::-::-:
...... =-**--:::-::---==~-..... . ---- -**- ---* ~ --- -- 1979 1979 1978 1974 1978 1977 1978 1973 Biometric Research Institute Consultant Mr. Doyle helped to select drug clinics for research with the narcotic antagonist naltrexone. Science Applications, Inc.
He also participated in design and construction of job expert review tests to validate selected training objectives and helped with statistical analysis of the results. The Catholic University of America Res.earch and Teaching Assistant Mre Doyle worked in the Human Performance Laboratory on
His duties included subject recruitment and data collection, using a computer. He also worked as a psychology department teaching assistant, teaching experimental th~ory, methods and rep0rt writing to an undergraduate . class in sensation and perception. -Friends Medical Science* Research Center, Inc. Research Assistant *and Counselor Mr* *. Doyle worked in the Narcotic Clinic, recruiting and interviewing subjects and collecting data on the narcotic antagonist naltrexone. He also counseled parolees with histories of narcotic addiction. Baltimore County Board of Education School Psychology Intern As a part-ti.me intern, Mr. Doyle worked on diagnostic evaluations of learning disabilities and emotional disorders of elementary and secondary school pupils. Spring Grove Hosoital Center Psychology Intern Mr. Doyle participated in the summer t~aining program. He tested patients and worked with them using behavior modification techniques. C-15 I I
PUB LI.CATIONS (. Ir*... i 'I REPORTS
Curran, _s. F., Doyle, P.A., and Sav~~e, c. "Maximizing Narcotic Antagonist (Naltrexone) Treatmen~ Through the Use of Behavioral Reinforcement." Paper presented at the National Drug Abuse Conference, San Francisco, California, 1977.. Doyle, P.A~ and Curran, S.F. "Delivery of Drug Abuse Treatment Services to Addicts in Community Corrections and Through Parole: A Status. Reporte" Paper presented at the National Drug Abuse Conference, Seattle, Washington, April, 1978. Savage, C., Curran, S.F., and Doyle, P.. A *. "A.Naltrexone/ Placebo Comparison Investigation.".A Multicultural View of Drug Abuse; the Proceedings of the National Drug Abuse Conference of 1977. Edited by D. E. Smith, s. M. Anderson, M. Buxton, N. Gottlieb, w. Harvey and T. Chuny. Schenkman Publishing co., Cambridge, Massachusetts, 1978. Burgy, D. c., Doyle, P.*A., Barsam, B. F., and Liddle, R. J. Applied Human Factors in Power Plant Design and Qperation. Columbia, MD1 General Physics Corporation, 1980 *. Gaddy, C. D., Turney, J. R., Cohen, s. L., and Doyle, P. A. Behavorial Science and Human Factors in Power.Plant Applications.* Columbia, MD1 General Physics Corporation, 1980. Topmiller, D. A., Burgy, D. C., Roth, D. R. ;. Doyle, i?. A * . and Espey, J. J. Survey and Analysis.of Communications Problems in Nuclear Power Plants (EPRI NP-2035) 501-5). Electric Power Research Institute: Palo 1\\l°to, CA:
"Preliminary Human Factors Engineering Recommendations for Near-Term Improvements of the Surry Nuclear Station Control Room" (Virginia Electric'& Power Company, GP-R-705). Columbia, MD, General Physics Corporation, June 1980. "Preliminary Human Factors Engineering Recommendations for Near-Term Improvements of the Zion Power Station Control Room" (Commonwealth Edison Company, GP-R-708).
"Swmnary of the LaSalle County Nuclear Generating Station Noise Report" (Commonwealth Edison Company, GP-R-13010). General Physics Corporation, Columbia, MD, August 1980. "Summary of the LaSalle County Nuclear Generating Station Lighting Survey" (Commonwealth Edison, *GP-R-13011). General Physics Corporation, Columbia, MD, August 1980.
r -. j l __. I
General Physics Corpo~ation, Columbia, MD, January 1981. "Preliminary Human Factors Engineering Recommendations for .Trojan Nuclear Power Plant" (Portland General Electric, GP-R-13106). General Physics Corporation,*Columbia, MD, September, 198le Doyle, P.A. "The Vicarious Emotional Responses of Idiopathic and Neurotic Sociopathsa" Master's Thesis, Loyola College, Baltimore, MD, 1977. Doyle, P.~. "Performance Effectiveness of Combat Troops: An Overview of. the PERFECT Computer Model." o.s. Army Research Institute, Alexandria, ~, 1981.* C-17
r**** r.. f *-* )' L,. r*** I I 1~ L_. i ~-.. ( -- EDUCATION 1978 - Present 1978 1976 EXPERIENCE 1979 - Present DONALD C. BURGY Ph.D. Candidate, Applied-Experimental Psychology, Catholic University _of America MeA., Applied-Experimental Psy~hology, Catholic University of America B.A., Psychology, Swarthmore College General Physics Corporation Manager, Human Factors Engineering _Human Factors Engineering and.Man-Machine Systems Design and Evaluation. Areas of human factors expertise include systems analysis, information processing, man-computer interactions, performance evaluation, training systems, and speech/non-speech communications. Applied resea~ch back-ground includes an emphasis in experimental design and methods, multivariate statistical analysis, mini/micro computer applications. and software. psychology~-. Experience in nuclear power plant control room reviews includes on-site field evaluations at North Anna, Surry,. Zion, LaSalle, Susquehanna (Advanced Control Room Design), Zimmer, Shoreham and Trojan Stations. Evaluations have included the application of current NRC Human Factors guidelines and existing military standards to control room designs as well as field and laboratory experimentation to validate criteria used in design tradeoff analyses. Experience in utility research and development efforts has included two EPRI studies entitled (1) a Survey and Analysis of Communication *Problems in Nuclear Power Plants and (2) an Operability Design Review of Prototype Large Breeder Reactors. Methodology for collection and analysis of real-time field data in power pl~t control rooms was developed as part of the communications study. Functions/Task analyses and operational seque_nce diagrams were generated as part of the operability design review that involved the evaluation of six breeder reactor designs
The human engineering aspects.of the program
. -* ~-. i L [.* i \\....... 1978 - 1979 1976 - 1978 1975 1976 PROFESSIONAL ORGANIZATIONS -~ AWARDS" 1978 involved the development of task analysis formats and collection methodology for the Acoustic Subsystem. Team performance improvement and training enhancement were primary goals of the systems development effort. Consultant. Private consulting in statistical design and. analysis, computer programming and applications, microcomputer systems and software psychology. Catholic University, Human Performance Laboratory Research Assistant Applied and basic research experimen-ts conducted on
Research sponsored by the Human Factors Engineering branch of the Office of Naval *Research. Additional research and related areas included auditory and visual pattern* recognition, performance measurement and evaluation, multidimensio~al scaling, and computer-based systems for acoustic and experimental data analysis. Computer experience involved programming. experimental events and subsequent data analysis on Digital Equipment Corporation PDP-8/e, PDP-11/34.and DECSystem-10 Computers. Eagleville Hospital- & Rehabilitation Center Research Assistant and Interviewer * !ntervh-..;ed study participants *and* assisted in data processing for an.Alcohol Abuse Research Grant and coordinat~d all programming and.clerical needs for a sub-study on Life *Stress Events. Skills in programming included.JCL, SPSS, PL/l, and FORTRAN on IBM 370/168 system_. Acoustical Society of America American Psychological. Association .Human Factors Society. National Conference on the Use of On-Line Computers in Psychology Psychometric Society Psychonomic Society Software Psychology Society Sigma XI Gr.ant-in-Aid of Research, National Sigma Xi
r-: I I \\.: \\ \\.... 1[ I , r. ! \\... l.... I. 1978 PUBLICATIONS AND PAPERS REPORTS Grant-in-Aid of Research, The Catholic Oniversity of America *Chapter of Sigma XI Burgy, D.C. nHemispheric Asymmetries in the Perception of Non-speech Sound Characteristics.n Unpublished master's thesis, The Catholic University of America, May 1978. Howard,.J.H. Jr., and Burgy, D.C. nstructure Preserving Transformations in the Comparison. of Complex Steady-State Soundsn (Technical Report ONR-78-6). Washington, D.C., The. Catholic University of America Human Performance Laboratory, December 1978. Howard, J.H., Jr.,_ and Burgy, D.C. nselective and Non-selective Preparation Enhancement Effects of an Accessory Visual Stimulus on Auditory Reaction Time.n Unpublished manuscript, The Ca~holic University of America, 1977 e Howard, J.H., Jr., Burgy, D.C.7 and Ballas, J.A. "A Deglitching Circuit for the AA50 D/A Converter." Behavior Research Methods and Instrumentation, 1978, 1Q_ (6), 858-860. Howard, J.H., Jr._, Ballas, J.A., and Burgy, D~C.* "Feature Extraction and Dec.ision Processes in the Classification of Amplitude Modulated Noise Patternsn (Technical Report ONR-78-4). - Washington, D.C., The Catholic University of American Human Performance Laboratory, July, 1978. Topmiller, D. A., Burgy, D. c., Roth, D. R., Doyle, P.' A., and Espey, J. J. Survey and Analysis of Communications Problems in Nuclear Power Plants (EPRI NP 2035). Electric Power Research Institute; Palo Alto, CA: EPRI, September, 1981. Burgy, D. c., Doyle, P. A~, Barsam, H. F., and Liddle, R. J. Applied Human Factors in Power Plant Design and Qperation. Columbia, MD; General Physics Corporation, 1980. nPreliminary Human Factors Engineering Recommendations for Near-Term Improvements of the Surry Nuclea.r Station Control
Columbia, 'MD, General Physics Corporation, June, 1980.
I I -- l "Preliminary Human Factors Engineering Recommendations for Near-Term Improvements of the Zion Power Station Control Room" (Commonwealth-Edison Company, GP-R-708).
General Physics Corporation1 Columbia, MD, December, 1980e "Summary of the LaSalle County Nuclear Generating Station Noise-Report" (Commonwealth Edison Company GP-R-13010). General Physics Corporation, Columbia,*MD, August, 1980. "Summary of the LaSalle County Nuclear Generation Station Lighting Survey" (Commonwealth Edison GP-R-13011). General Physics Corporation, Columbi~, MD, August, 1980 * . "Human Factors Engineering Considerations for Implementing a_ 'Green Board' at Zion. Nuclear Generating Station" (Commonwealth Edison GP~R-31008). Columbia, MD, August,- 1980.
Task Analysis of Nuclear Power Plant Control Room Crews" (USNRC Office of Nuclear Regulatory Research). Columbia, MD: General Physics Corporation, March, 1982. "Human Factors Engineering *Meter Banding Study" '(Commom:aalth Edison Company GP-R-13016). General Physics Corporation1 Columbia, MD, September, 1980. C-21
EDUCATION 1977 1975 EXPERIENCE 1981-Present 1980-1981 I CLAUDIA LEMEGES M.S., Education, State University College of New York at Buffalo B.S.., Communication Disorders, State Univer.sity College of New York at Geneseo General Physics Corporation Staff Scientist Ms. Lempges is a member of the Human Factors Group. She is responsible for specifying education and training requirements and program development in this* area. She is currently working on a task analysis project of control. room operating crews. On this project, she has b~en
collection methodology. She will also be responsible for data collection. As part of the development _phase of this project, Ms. Lempges spent time at the Institute of Nuclear Power operations.* She observed all phases of their *Job and Task Analysis of Control Board Operators* project, ~rked as a member of their quality control review team, and participated in their development of a methodology for writing terminal learning objectives and job performance measures. Ms. Lempges has been on-the review team for* a detailed control room design review. For this project, she developed an operating event selection methodology, as required by NUREG-Oi'.00. She has also reviewed instrumentation in a control.room for human engineering discrepancies and developed system functional descriptions for use in operator/system interface task analysis. Ms. Lempges participated in the development of Instrumentation and Control Technician Certification . program, based upon a job analysis, in conjunction with Limerick Training Center I&C instructors.* Buffalo Public Schools Teacher Ms. Lempges taught learning disabled students *. she was responsible for evaluation, writing and implementation of specific behavioral objectives and classroom planning.
1977-1980 1977" PUBLICATIONS Erie County Association for Retarded Children Speech Pathologist Ms. Lempges was responsible for evaluation, writing and implementation of s~cific behavioral objectives for communication programs for severely retarded studentso She was also responsible for inser.vice planning for s.taff and
Childrens Hospital Behavioral Sciences Dept. (Buffalo, NY} Graduate Intern Ms. Lempges was responsible for data collection: planning and implementation of communication program for autistic children. Boland, L., Dewaters, J. and Lempges, c. Heritage School Communication Program: A Comprehensive Overview. Buffalo.,C-- NY: Erie County ~ssociation _for Retarded Children, 197.9.
Integrated Speech and Gross Motor Program for Severe;y Retarded Students. Buffalo~ NY: Erie County Associa.tion for Retarded Children, 1980
EDUCATION 1980 - Present 1973. 1972 EXPERIENCE 1982 - Present '1960 - 1982 ,~*.. FRANK B. ROGALLA M.S.. Program, Human Factors Engineering Program,** University of Michigan B.A., Psychology, University of.Connecticut, Storrs, Connecticut. Areas of specialization: Industrial and Experimental Psychology. B.S., Electrical Engineering, University of Connecticut. Areas of specialization: Biomedical Instrumentation and Computer Science. General Physics Corporation Senior Engineer, Human Factors Engineering Mr. Rogalla is assisting in an EPRI-sponsored project investigating Internal Plant Operational Commun~cations. ' Be is also assisting in the Salem Nuclear Generating Station Units 1 and 2 Detailed Control Room Desi.-gn Review. Combustion Engineering Corporation (C-E) Senior Nuclear Engineer Instrumentation and Controls Engineering Section Human Factors Engineering duties included developing the informational man-machine interface using computer-based cathode ray tube (CRT) display systems. The systems involved were Accident Monitoring System, Critical Functions Monitoring System, Safety Parameter Display System (SPDS), Qualified Safety Parameter Display* System (QsPDS) and the Advanced Control Room Design, Nuplex 80. The tasks involved designipg the display set organization by, developing a hierarchy and then structuring each display pag.e to supply the required system information using accepted human factors engineering principles and . practices. A good;.xample of this effort was the production. of the Plant Monitoring System Supplementary Hierarchy for TVA. The Supplementary Hierarchy added many innovations to existing CE display technology. Some examples are: a hierarchical structure_of safety syst~ms and operational systems, new symbols, symbol types, symbol behaviors, new display types and new ways of coding. Other tasks.involved the hardware design for computer-man interaction, A simulator instructor station control board and the design and review of controls and panels.
L r**** I L. [ r* 1 '
1976 - 1980 1973 1976 1973 In order to effectively accomplish these ta-sks it was necessary to take CE's Nuclear Power Plant Operators short Course with actual power*plant*simulator training and have extensive discussions with system designers and operational per.sonnel. Mr. Rogalla Participated in CE'*s advanced accident monitoring and display systems design program that included workshops by noted authors, for example Rasmussen & Goodstein*. Mr. Rogallas' _efforts that were incorporated by the company as policy are:
ISD-82-103.
ISD-81-661.
ISD-80-1169.
Hartford Techology Consultants & State Reception S¥stems Owner, ope;-ator Mr. Rogalla provided electronic engineering services on a consultant basis~ He operated an electronic signal systems business,* designing, installing, and repairing intercom, sound systems, closed circuit television systems,_ and antenna systems for the private and public sector *.
University of Conecticut Health Center Assistant Director 'of Physical Plant
Dental/Medical and Research Facility. The systems included radio* paging, nurse call, intercom-sound systems computer and closed circuit television systems *. The-task involved system conceptualization, specification writing and supervision of installation.. The task also involved providing training courses for-the operation and maintenance of the systems~ I?ynamic Controls Corporation Test Engineer Mr. Rogalla provided the liaison* between the Engineering Department and the Electronic Production Department. Duties included assisting in the final stages of design/development* and production of the U.S. Air Forces F-15 Eagle's armament system. The task involved the design of tests, testing and incorporation of changes. The task required. the ability to determine a problem area, have
- -------------*---. ------~- - µ
1970 - 1973 tests taken, determine' a fix act~on with the engineering department# and then have the fix in~orporated and then retest. University of Connecticut at Storrs Spec'ial Research Assistant Mr. Rogalla assisted in the design and development of biomedical instrumentation and instrumentation systems. Solid state electronics were used for the measurement and monitoring of brain wa.ves (EEG's) and muscle signals.* (EMG's) and (EKG's).
l L.. r 1 '~* \\.*.. ~UC~ION. 1981 1964 1967 1963 - 1964 EXPERIENCE 198 l - Present 1978 - 1981 1977 - 1978 1975 - 1977 RICHARD A. CORFIELD B.S., Physics, University of the State.of New York* Undergraduate Studies, Physics, *Pennsylvania State University Naval Nuclear Power School and Prototype Training General Physics Corporation* Director, Columbia Power Services Mr. Corfield heads the Columbia Power Services department * . He directs and coordinates the activities of the department including personnel recruiting and selecting, sales and client contacts, program developnent, plann_ing and cost control. His department provides on"'."si te training and training materials developnent programs and other operations support services to nuclear utility clients. General Physics Corporation Manager, PWR Programs Mr. Corfield managed Pressurized Water Reactor training. He was in charge of systems training projects and programs, as well *as spec~alized training projects dealing with PWR power stations. He was responsible for the coordinat,ion, scheduling and cost control of training ma*terial
He de"?eloped and presented courses in thermodynamics, heat transfer and fluid flow. Gc:neral Physics Corporation Supervisor, Training Projects Mr. Corfield was responsible for supervising the writing and editing of Systems Training Manuals detailing the purpose, description, operation and design bases of the systems associated with PWR power.stations. He also conducted academic and technology training and requalification training programs for various utilities. Public Service Electric and Gas Company of New Jersey Nuclear Staff Assistant, Salem Generating Station Mr. Corfield was a training instructor at Salem. He helped to develop training programs and materials, he trained reactor operator and senior reactor *operator candidates during both the initial NRC licensing and the requalification programs. He held a Senior Reactor Operator's License on the Salem Unit.
1971 1975 1967 - 1971 1960 - 1967 U.S. Naval Nuclear Power School Classroom Instructor, Bainbridge? Maryland Mr. Corfield was.. an instructor for prospective operators of Naval Nuclear Power Plants in the subjects of Reactor Plant Technology, Reactor Plant Operations, and Electrical Theory7 college level courses concerning the design, construction, operation and operational characteristics of reactor plant systems for energy transfer and reactor monitoring and control. U.S. Navy Reactor Control Division Supervisor, Nuclear Submarine Program Mr., Corfield was in* charge of preventive and corrective maintenance for Instrumentation and Control equipnent for the nuclear plant. He supervised and trained personnel in the operation of all power plant equi:i;ment, watch standing practices, and techniques for containing and controlling ship's* casualties and rad~ological hazards. U.S. Navy Reactor Operator/Technician Mr. Corfield attended various schools and training programs and served in the* electrical division aboard ship during* his first several year.s in the Navy. CERTIFICATIONS/ASSOCIATIONS 1977 Senior Reactor Operator License NO. SOP-2975 Salem Nuclear Generating Station Member, American Nuclear Society
~ I ,.~ r*- 1 L._ l - L [ L. 4 EDUCATION 1970 - 1974 1978 EXPERIENCE 1981 - Present 1980 - 1981 1979 - 1980 1975 - 1979 -~- P~TRICK W. CASEY U.S. Naval Nuclear Power Training Program Commercial Nuclear Power Plant Operator's License Class, Virginia Electric and Power Company General Phvsics Corporation Manager, PWR Services Mr. Casey manages Pressurized Water Reactor Services. He is-in charge of operator training programs as well as specialized training projects dealing with PWR power stations. He is responsible for the coordination, scheduling and cost control of training material preparation, on-site licensed and non-licensed training and training program <;ieveloptnent;. He is' certified by General Physics as a _Senior Reactor Operator Instructor. General Physics Corporation Senior Specialist At Gener~l Physics, Mr. Casey has participated as the senior instructor in several Reactor Operator/Senior Reactor Operator license courses and STA programs *. He has also served as the on-site project supervisor tor an accelerated Senior Re,actor Operator Is license course *. General Physics Corporation Staff Training. Specialist Mr. Casey-prepared training materials for nuclear power plant operator license candidates-and technicians. Those materials included systems descr_iptions and training aids. He also prepared course materials and instructed in on-site training programs. Virginia Electric and ~ower Company License Reactor Operator, North Anna Power Station Mr. Casey participated as a control panel operator in the initial startup, testing, and day-to-day operation of North Anna Unit 1. He also w~ote plant operating, abnormal and emergent:Y procedures for the North Anna Station. Mr. Casey earned his Reactor Operator's License on North Anna Unit l. c-29
i I. 197cf' 1974 ~ - - -- - - --~.;. - U.S. Navy Nuclear Submarine Propulsion Plant Oi?erator - Electrical .111. Operator Mr. Casey was responsible for operating* and 'maintaining the shipboard electrical equipment aboard an SSBN type nuclear ~.'submarine. He also participated in the refueling, testing and startup of the new reactor core during overhaul. ..3 =.i}}