uml21_plt_onb1MW_whcf P = 1 MW, FR = 2.1, Tin = 43 C, with HCFs, vary DP for ONB 0 0 0 1 0 1 1 0 1 3 1.0 1.240 1.250 1.350 1.5 4.361E-03 6.604E-02 1.143E-01 1.000E+00 0.000E+00 0.000E+00 6.350E-01 1.000E+00 4.361E-03 6.604E-02 1.524E-01 2.000E+00 0.3160 0.2500 19 3 3 3.420 2.595E-03 0.5969 3.800E-04 5.100E-04 9.784E-05 0.0 0.0690 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 1.957E-04 0.0 0.1380 0.0 9.784E-05 0.0 0.0690 0.0 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 6.604E-02 0.00 2.10 2.00 1.90 1.80 1.70 1.60 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 0.00 0.00030 0.00002 0.00050 0.04762 43.00 0.1724 100 0.0001 21 0.00 0.39 0.05 0.33 0.10 0.38 0.15 0.44 0.20 0.51 0.25 0.59 0.30 0.69 0.35 0.81 0.40 1.00 0.45 1.21 0.50 1.36 0.55 1.45 0.60 1.49 0.65 1.50 0.70 1.48 0.75 1.42
0.80 1.34 0.85 1.22 0.90 1.09 0.95 0.99 1.00 1.17 0