I I
PS~G
- Public Service Electric and Gas Company 80 Park Plaza Newark, N.J. 07101 Phone 201/430-7000 December 3, 1981 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, MD 20014 Attention:
Gentlemen:
Mr. Steven A. Varga, Chief Operating Reactors Branch 1 Division of Licensing FEEDLINE WATERHAMMER TEST NO
- 2 UNIT SALEM NUCLEAR GENERATING STATION DOCKET NO. 50-311 Pursuant to paragraph 2.C{l4) of Facility Operating License DPR-75, we have satisfactorily completed the feedline waterharomer test to demonstrate that anticipated feedwater transients to the steam generator will not result in unacceptable waterharomer damage.
We have reviewed the results of this test and find them acceptable.
A report of the results of this test is enclosed for your review.
The test procedure was approved by your letter of June 25, 1981 prior to conducting the test.
Should you have any questions, do not hesitate to contact us.
EAL:em cc Mr. Leif Norrholm Senior Resident Inspectoi Mr. Gary c. Meyer Licensing Project Manager 8112180332 811203-.
PDR ADOCK 05000311*
P PDR The Energy 1euµ1e very truly yours,
~
//