ML18086A579

From kanterella
Jump to navigation Jump to search
Forwards LER 81-043/03L-0
Date released: 11/29/2018 Download: ML18086A579


LER 81-043/03L-0:on 810505,while Performing Surveillance Procedure Sp(O) 4.6.1.3 on Containment Air Lock,Leak Rate Exceeded Tech Spec Limits.Caused by Outer Door Seal Not Maintaining Test Pressure.Seals Were Reversed
ML18086A580
Person / Time
Site: Salem PSEG icon.png
Issue date: 05/22/1981
From: Espey J
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18086A580 (1)
Forwards LER 81-043/03L-0
ML18086A578
Person / Time
Site: Salem PSEG icon.png
Issue date: 05/22/1981
From: Uderitz R
Public Service Enterprise Group
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML18086A578 (2)